background image

2

Contents

1.0  GENERAL INFORMATION ...............................................  2

2.0  DESCRIPTION ................................................................  3

3.0  INSTALLATION ................................................................  4

4.0  OPERATION ...................................................................  7

5.0  MAINTENANCE ..............................................................  9

WARRANTY ..........................................................................  11 

IMPORTANT

READ PRIOR TO STARTING THIS EQUIPMENT

UNPACKING

This shipment has been thoroughly checked, packed and 

inspected before leaving our plant. It was received in good 

condition by the carrier and was so acknowledged.
1)  Check for Visible Loss or Damage. If this shipment shows 

evidence of loss or damage at time of delivery to you, 

insist that a notation of this loss or damage be made on 

the delivery receipt by the carrier’s agent.

2)  Check for Concealed Loss or Damage. When a shipment 

has been delivered to you in apparent good order, but 

concealed damage is found upon unpacking, notify the 

carrier immediately and insist on his agent inspecting 

the shipment. Fifteen days from receipt of shipment is 

the maximum time limit for requesting such inspection. 

Concealed damage claims are not our responsibility as our 

terms are F.O.B. point of shipment.

1.0  General Information

CAUTION

A.  Pressurized devices-

This equipment is a pressure containing device.
•  Do not exceed maximum operating pressure as shown 

on equipment serial number tag.

•  Make sure equipment is depressurized before working 

on or disassembling it for servicing. 

B. Electrical-

This equipment requires electricity to operate.
•  Install equipment in compliance with national and local 

electrical codes.

C.  Breathing air-

•  Air treated by this equipment may not be suitable for 

breathing without further purification. Refer to OSHA 

standard 1910.134 or other applicable standards for 

the requirements for breathing quality air.

Содержание Hankison DHW 13

Страница 1: ...Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm FOR M NO 3215738 R EVI S ION 07 2014 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N...

Страница 2: ...cking notify the carrier immediately and insist on his agent inspecting the shipment Fifteen days from receipt of shipment is the maximum time limit for requesting such inspection Concealed damage cla...

Страница 3: ...ssurization valve D and exhaust muffler E to atmo sphere After a set time the automatic solid state timer closes purge repressurization valve D allowing TOWER 2 to repres surize slowly At the end of 2...

Страница 4: ...8 6 22 158 6 22 158 27 5 699 27 5 699 27 5 699 27 5 699 27 5 699 27 5 699 39 3 998 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT F 1 2 NPT...

Страница 5: ...o at least 120 F 49 C Use aftercooler and separator if higher temperatures are present A 1 2 1 2 C DESICCANT DRYER COMPRESSOR AFTERCOOLER SEPARATOR A B D PREFILTERS AFTERFILTERS NOTE Installation of a...

Страница 6: ...pressure gauge to ensure proper flow direction through filter 3 5 Wall mounting Four holes are provided in rear of cabinet Attach cabinet to wall using four 4 screws User is responsible for select in...

Страница 7: ...for various inlet pressures INLET PRESSURE psig 50 60 70 80 90 100 110 120 130 140 150 kgf cm2 3 5 4 2 4 9 5 6 6 3 7 0 7 7 8 4 9 1 9 8 10 5 Multiplier 0 31 0 42 0 54 0 73 0 83 1 00 1 09 1 17 1 26 1 3...

Страница 8: ...by multiplying Average Purge Flow at 100 psig from Table 1 by Purge Flow Correction Factor from Table 4 2 7 x 1 17 3 2 scfm the average purge flow Step 4 Find Minimum Outlet Flow available by subtrac...

Страница 9: ...eep containers closed until use to avoid mois ture contamination If desiccant is exposed to air it can be heated in an oven at 400 F for four hours before use or the next procedure can be used 2 If th...

Страница 10: ...115V 3209763 3209763 3209764 3209764 3209764 3209764 3247596 PURGE REPRESSURIZATION VALVE 230V 3209765 3209765 3209766 3209766 3209766 3209766 3247597 MAINTENANCE KIT Dryers Made After September 19 2...

Страница 11: ...nty and any resulting charge or subsequent claim will not be paid Products repaired or replaced under warranty shall be warranted for the unexpired portion of the warranty applying to the original pro...

Страница 12: ...hankison americas spx com www spx com hankison Improvements and research are continuous at SPX Specifications may change without notice ISSUED 07 2014 Form No 3215738 Revision G COPYRIGHT 2014 SPX Co...

Отзывы: