background image

18

Depth, current and compass readouts

 WARNING!  Never use the depth measurement readout as a guide for 

mechanical or other digging activity. Always follow safe digging guidelines.

The ACCUPOINT locator can measure and display the utility depth, locate signal 

current and the relative orientation of the cable or pipe to the locator. This helps you to 

make sure that you are following the right cable or pipe, especially when other utilities 

are present.
The ACCUPOINT locator features TruDepth

, a feature that helps you to ensure the 

accuracy of your locates. The depth and current are automatically removed from the 

display when the locator is at an angle of more than 7.5° from the path of the cable or 

pipe being located, or when the locator determines that signal conditions are too poor 

for reliable measurements.

Using accessories

Sondes, Flexrods and FlexiTrace

Sondes are transmitters that are useful for tracing non-metallic pipes and sewer and 

storm pipelines. Battery powered sondes can be fixed to Flexrods to allow them to 

be pushed through pipes or conduits, and some are suitable for blowing through 

ductwork. Sondes integral to pipeline inspection systems are suitable for the location 

and assessment of sewer and storm pipeline systems during inspection.

A FlexiTrace is a traceable fiberglass rod incorporating wire conductors with a sonde 

at the end. It is connected to the output of the transmitter and is typically used in small 

diameter, non-metallic pipes. The user has the option of locating the entire length of 

the cable or choosing to locate only the tip of the cable.
The FlexiTrace has a maximum power rating of 1W. When using the FlexiTrace with 

a ACCUPOINT MS620 transmitter, the output limit must be set to 1W in the MAX P 

menu and the output voltage limit set to LOW in the MAX V menu.

Содержание CUES ACCUPOINT MS611

Страница 1: ...Sewer and storm industry sonde and line locator kits User Guide...

Страница 2: ...2...

Страница 3: ...e attempting to operate the ACCUPOINT locator and transmitter This guide is intended as a quick reference guide only For detailed instructions including the use of accessories help with eCert please r...

Страница 4: ...hether a signal is from a single cable or from several in close proximity WARNING Batteries can get hot after prolonged use at full output power Take care while replacing or handling batteries WARNING...

Страница 5: ...is safety equipment which should be regularly checked to ensure its correct operation eCert provides a thorough test of the ACCUPOINT s locating circuitry and supplies a CUES Calibration Certificate...

Страница 6: ...6 9 ACCUPOINT MS611 locator 6 7 11 12 13 14 13 15 16 17 17 26 28 18 19 20 21 22 24 27 25 23 10 1 2 4 5 3 8...

Страница 7: ...en icons 15 Signal strength bargraph with peak marker 16 Signal strength readout 17 Proportional Guidance arrows 18 Battery level 19 Sensitivity readout 20 Volume level 21 Power Mode icon 22 Accessory...

Страница 8: ...8 MS620 transmitter 4 2 1 3 10 11 12 13 14 15 16 17 18 5 6 7 8 9...

Страница 9: ...e key Transmitter screen icons 10 Battery level indicator 11 Operation mode readout 12 Standby icon 13 Output level indicator 14 Clamp icon Indicates when a signal clamp or other accessory is connecte...

Страница 10: ...signals and Increase and decrease gain Accupoint automatically sets gain to mid point when pressed Rapidly increase and decrease gain steps in 1dB increments KEY SHORT PRESS LONG PRESS Enter the menu...

Страница 11: ...ter from a mains or vehicle power source using a CUES supplied optional accessory adapter System setup It is important that you set up the system according to regional operational requirements and you...

Страница 12: ...OW Select proportional Guidance arrows in Peak mode COMPA Enable or disable display of the Compass feature VALRT Enable or disable the vibration feature AUDIO Select High or Low sound levels SWING Ena...

Страница 13: ...u using the or arrows 3 Press the key on the locator or the key on the transmitter to enter the BATT menu 4 Scroll up or down to select the correct battery type Alkaline or Nickel metal Hydride 5 Pres...

Страница 14: ...to the pipe or cable you wish to survey using the red Direct Connect lead supplied The black lead is generally connected to earth using the supplied ground stake The transmitter will then apply a dis...

Страница 15: ...tworks Once in Power Mode press the key to switch out of CUES s sensitive Power Mode and scroll through five individual Power Filters This enables operators to establish if a single large power signal...

Страница 16: ...ld be moved towards the target line The target position indicator indicates the target positioned to the right of the locator and can be used to guide the locator towards the target line The signal st...

Страница 17: ...et line enabling both depth and current readings to be displayed As the locator is moved towards the left the tail on the proportional right arrow will reduce the target position indicator will move f...

Страница 18: ...urements Using accessories Sondes Flexrods and FlexiTrace Sondes are transmitters that are useful for tracing non metallic pipes and sewer and storm pipelines Battery powered sondes can be fixed to Fl...

Страница 19: ...r set to maximum With the sonde in place at the survey location hold the locator vertically and directly over the sonde s estimated position Make sure the blade is in line with the sonde Adjust the se...

Страница 20: ...display indicates a clear peak response 4 Repeat Steps 1 to 3 in smaller increments with the locator blade resting on or near the ground The locator should now be directly above the sonde with the bla...

Страница 21: ...lty Batteries and power supply Only use the rechargeable battery packs chargers and power supplies approved by CUES If not using rechargeable packs use good quality Alkaline or NiMH batteries only Bat...

Страница 22: ...cturer s warranty and may damage the equipment or reduce its performance Service and maintenance Regularly check your equipment for correct operation by using the Self Test function and eCert The loca...

Страница 23: ...m PC companion and it allows you to manage and customize your locator ACCUPOINT Manager Online is also used to retrieve and analyze survey and usage data run an eCert calibration and to perform softwa...

Страница 24: ...ole or in part without the prior written consent of CUES Inc Due to a policy of continued development we reserve the right to alter or amend any published specification without notice Trademarks CUES...

Отзывы: