4
WARNING! Direct connection to live conductors is POTENTIALLY LETHAL.
Direct connections to live conductors should be attempted by fully qualified
personnel only using the relevant products that allow connections to energized
lines.
WARNING! The transmitter is capable of outputting potentially lethal
voltages. Take care when applying signals to any pipe or cable and be sure to
notify other technicians who may be working on the line.
WARNING! Reduce audio level before using headphones to avoid damaging
your hearing.
WARNING! This equipment is NOT approved for use in areas where
hazardous gases may be present.
WARNING! When using the transmitter, switch off the unit and disconnect
cables before removing the battery pack.
WARNING! The ACCUPOINT MS611 locator will detect most buried
conductors but there are some objects that do not radiate any detectable signal.
The ACCUPOINT MS611, or any other electromagnetic locator, cannot detect
these objects so proceed with caution. There are also some live cables which the
ACCUPOINT MS611 will not be able to detect in Power mode. The ACCUPOINT
MS611 does not indicate whether a signal is from a single cable or from several
in close proximity.
WARNING! Batteries can get hot after prolonged use at full output power.
Take care while replacing or handling batteries.
WARNING! Only use charging equipment provided by CUES. The use of
alternative chargers may cause a safety hazard and/or reduce the life of the
battery.
CAUTION: Do not let your battery completely discharge as this may reduce its
life or damage it permanently. If you are not using your equipment for a long
period do charge them at least once a month.
WARNING! Batteries can get hot after prolonged use at full output power.
Take care while replacing or handling batteries.
WARNING! Do not tamper with, or attempt to disassemble the battery packs.
CAUTION: If battery failure is suspected or if the battery shows any sign of
discoloration / physical damage return the entire unit to an authorized repair
center for investigation and repair. Local, national or IATA transport regulations
may restrict the shipment of faulty batteries. Check with your courier for
restrictions and best practice guidelines. Your local CUES representative will be
able to direct you to our authorized repair centers.
NOTE: The charging temperature range is 0 to 45 °C, 32 to 113°F. Do not attempt
to recharge your batteries outside this temperature range.
Содержание CUES ACCUPOINT MS611
Страница 1: ...Sewer and storm industry sonde and line locator kits User Guide...
Страница 2: ...2...