Waukesha Cherry-Burrell Brand W71/W72RS Sch. 5 Mix Proof Valves
Installation
08/2018
95-03091
Page 11
Connect the cavity cleaning supply to a suitable liquid supply to
flush the vent/drain (Figure 7) during the operation of the
processing system.
The flush supply line can be connected to the pipe system by 1/4"
(6 mm) rigid or poly flow tubing. The flush supply is blocked when
the valve is open.
Connect the supply line to the adapter connection with poly flow
tubing (Figure 7).
WARNING
During CIP cleaning and valve opening (W71), fluid escapes from
the drain port. Drain this off to prevent a possible hazard to per-
sonnel.
Regulate the flush supply (Figure 7, item A) for pressures of 30
psi minimum, 50 psi maximum.
The maximum solution temperature is 180°F (60°C).
WARNING
Cavity cleaning operation must fall within the fail-safe control sys-
tem. See “Cleaning” on page 23.
WARNING
Take proper precaution to safeguard the flush water supply, such
as installing backflow prevention devices.
External Flush - Steam
Vent Cavity
Figure 8 - External Steam Barrier -
upper stem
VA100-642
VA100-420B
Steam Vent Cavity, Upper and Lower Stem
Use both Upper Stem Steam Flush Adapter and Lower Stem
Steam Adapter.
This option allows continuous steaming of the vent cavity (in both
open and closed positions), upper and lower stems.
DANGER
Valves equipped with the steam flush option for stem and vent
cavity can produce high temperatures and steam hazards that
may result in personal injury or death.
To steam flush the upper and/or lower stem as well as the vent
cavity, the Mix Proof Valve must be ordered with the Steam Flush
for stem and vent cavity. This option (See Figure 9 on page 12)
contains the following components:
•
External flush connection, 1/4" NPT.
•
Modified adapter with removed o-rings to flush the stem.
•
Jacket with 1/4" Tube (S.S.) on lower balancer to flush the
lower stem (balancer).
•
EPDM gaskets for all seals in the wetted area.
Figure 7 - Connection of Flush Supply
A