Setup Instructions continued
3. Hydraulic Lines and Fittings.
•
Hydraulic lines and fittings can restrict flow to a cylinder or hydraulically actuated device. The
restricting or slowing of the fluid flow causes back pressure that slows the device’s return. Return speed
also varies because of the application, condition of the cylinder or device, inside diameter of hose or
fitting, length of the hose, and the temperature and viscosity of the hydraulic fluid.
• Tubes and Hoses should be routed in such a way that they can easily be serviced or removed as well
as provide the least resistance to fluid flow. See below for recommended routing configurations.
TUBING
HOSES
CORRECT
INCORRECT
CORRECT
INCORRECT
4. 18VDC Battery & Charger
NOTE:
New batteries must be charged before first use. Approx. 60 minutes of charging = 100% battery
fuel.
A. Ensure battery charger is plugged in.
B. Slide battery pack into charger as shown and allow battery to charge.
C. Once battery is adequately charged it can be installed on pump unit as shown.
D. To remove the battery from the pump unit press the release buttons on the sides of the battery.
E. Slide the battery out of the pump unit as shown.
B.
A.