Other Features
•
Bucket Full Light: Illuminates when the bucket is full and needs to be emptied; or when
bucket is removed or not properly seated.
•
Auto Shut Off: The unit shuts off after 30 seconds when bucket becomes full or when
bucket is removed / not properly seated; or when set humidity is reached (the fan motor will
continue to run for additional 3 minutes then stop).
•
Auto Defrost: When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
•
3 Minute Delay: After the unit has stopped (or powered off), there will be a 3-minute delay
before it will resume operation again. This is to protect the compressor. Operation will
automatically start after 3 minutes.
•
Check Filter Feature: The system begins calculating the time once fan motor begins
operation. The check filter feature will be activated when operation time achieves 250 hours
or more - the clean filter indicator light will begin to flash. After filter has been cleaned and
replaced, press the Filter button to reset and the clean filter indicator will go off.
•
Auto-Restart: If the unit breaks off unexpectedly due to power cut, unit will resume at
previous setting when power returns.
•
Timer On and Timer Off: Unit can be set to auto-start/stop, up to 24 hours:
o
When unit is on: press of the Timer button and the Timer-Off indicator will illuminate
(indicating auto-stop is initiated). Press Timer button again and the Timer-On indicator
will illuminate (indicating auto-start is initiated).
o
When the unit if off: press of the Timer button and the Timer-On indicator will illuminate
(indicating auto-start is initiated). Press Timer button again and the Timer-Off indicator
will illuminate (indicating auto-stop is initiated).
o
Press or hold the +/- buttons to change the set time in 0.5-hour increments, up to 10
hours; then in 1-hour increments, up to 24 hours.
o
The selected time will register after 5 seconds and the panel will revert back to
displaying ambient humidity.
o
When both auto-start and auto-stop times are set, both Timer On and Off indicator lights
are illuminated, identifying both On and Off timers are now programmed.
o
Turning the unit on or off at any time or adjusting the timer setting to 0.0 will cancel any
timer programs.
o
Timer program is also cancelled when LED displays P2 error code.
o
The control will count down the remaining time.