![SPT SD-31E Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/spt/sd-31e/sd-31e_instruction-manual_1352179010.webp)
9
TECHNICAL SPECIFICATIONS
MODEL
SD-31E
SD-41E
SD-61E
SD-71E
Moisture Removal **
30 pints per day
40 pints per day
60 pints per day 70 pints per day
Power Supply
115V / 60Hz
Current
3.0A
4.5A
4.9A
6.9A
Power Consumption
310W
450W
550W
720W
Energy Factor (EEV)
1.85 L/kWh
Starting Current
14A
21A
28A
33A
41 ~ 95
°
F
Working Environment
35% to 85% RH
Water Tank Capacity
3L
6L
Air Flow (High//Low)
245/210 m3/h
320/280 m3/h
Noise Level (High)
56 dB(A)
58.5 dB(A)
Dimension
14.17(W) x 10.24(D) x 19.88(H) in.
15.35(W) x 10.98(D) x 23.15(H) in.
Net/Gross Weight
29/31 lbs
30/32 lbs
40/42 lbs
** Capacity will vary according to actual room ambient temperature and humidity conditions.
TROUBLE SHOOTING
BEFORE COTACTING THE MANUFACTURER, PLEASE CHECK THE FOLLOWING
POSSIBILITIES.
PROBLEM
CHECK
Unit fails to start
•
Power is OFF or power cord is unplugged/not securely fitted.
•
Water bucket is not placed properly
•
Water bucket is full or set humidity has been reached
•
Check power to the outlet, fuse/circuit breaker box
Performance decreased
•
Blocked air filter
•
Room windows and doors are open
•
Obstacles in air outlet or inlet
•
Not enough time allowed to remove the moisture
•
Humidity setting may be set too high
•
Ambient temperature is too cold, below 41°F
Unit is noisy
•
Unstable setting of unit or floor surface is not level
•
Blocked filter
Frost appears on coils
•
This is normal. The dehumidifier has Auto-Defrost feature
Water on floor
•
Hose connection for continuous drainage is loose
•
Intend to use the bucket for water collection, but the drain plug is removed.
ES, AS P2 and EC
appears in display
•
Refer to error codes on page 4.
Unit is not collecting as
much water during the
winter months
•
When temperature is low, absolute humidity level will drop as well, even
when relative humidity is at the same percentage. There is less water
vapor in the air when temperature is low
Difficulty inserting the
continuous drain tube
•
Soak the plastic white connector in hot water for a few minutes will soften
the plastic and make it easier to connect.
If you still cannot solve the problem after trying the above, unplug unit and contact Sunpentown Int’l Inc.