26
Anybus Option Modules
4.7.2 Baud Rate
The Baud Rate is set by parameter
224)FBUS
224)FBUS
BAUD
BAUD
RATE
RATE
.
0
125kbps
1
250kbps
2
500kbps
4.7.3 Node Address (MAC ID)
The Node Address is set by parameter
202)FBUS
202)FBUS
NODE
NODE
ID
ID
.
Note that a power cycle of the drive may be necessary before a change takes effect.
4.7.4 Cyclic Data
The Cyclic Data (Process Data) is transferred using the Producing Assembly and Consuming
Assembly.
•
Configure the Producing Assembly “Input Data” (T
g
O) to match the number of words
used by the FIELDBUS
GET
GET
FROM
FROM
s.
•
Configure the Consuming Assembly “Output Data” (O
g
T) to match the number of
words used by the FIELDBUS
GOTO
GOTO
s.
4.7.5 Acyclic Data
Parameters can be accessed acyclically from the Scanner/PLC by Set_Attribute and Get_
Attribute CIP object services.
Class
= 162 (A2h)
Instance
= parameter number
Attribute
= 5
Size
= 2 (2bytes)
For example:
409)SUMMER
409)SUMMER
1
1
INPUT
INPUT
2
2
is
Class:Instance:Attribute:Size 162:409:5:2
4.7.6 Electronic Data Sheet
DeviceNet eds files:
005A002B003F0100.eds PLX or JLX M40
005A000000620200.eds
PLX or JLX
M30