10
Installation
1
+10 V precision reference. 10 mA maximum. Short-circuit proof
2
Minimum end of setpoint potentiometer or 4-20 mA current loop I/P
3
Speed demand input, 0-+10 V for 0-100% speed
4
Common - 4-20 mA return
5
Common - connect to earth for protective Class 1
6
Auxiliary input - on-board jumper selects direct speed or torque mode (0-10 V for
0-100% control)
7
Connect to COMMON to run 60 ms ON / 20 ms OFF
(WARNING: Run is an electronic inhibit function. The field remains energised and
all power terminals remain "live". RUN must not be relied upon during hazardous
operations)
8
Common - internally connected to T4, T5, T58, T68
9
Tacho input 25-400 V full scale, + or - polarity
10
Relay contact, normally-closed
11
Relay contact, normally-open
12
Relay pole
A1+
+armature output
A2-
-armature output
L2/N
AC supply input according to supply select jumper
L
AC supply input according to supply select jumper
F2-
-field output
F1+
+field output
Relay contact rating: 1 A, 240 Vac
RATINGS ACCORDING TO CSA:
voltage rating of relay terminals
10/11/12 must not exceed 30 Vac
or 42.4 Vdc
Figure 12
3200i Terminal specifications
Top terminals
68
Drive common
67
+24 V output, 25 mA maximum -
do not short
66
Auxiliary speed input, 0 to +10 V for 0-100% ramped speed
65
Auxiliary inverting speed input, 0 to -10 V for 0-100% ramped speed
64
Input to current loop, 0-5 V for 100% current
63
-12 V output 10 mA maximum -
do not short
62
Stop/start input:
close to -12 V to activate stall condition
close to +12 V to release stall condition
61
+12 V output, 10 mA maximum -
do not short
58
Drive common
57
Speed demand output 0 to -10 V represents 0-100% demand (output impedance 1 kΩ)
56
Speed output - typically 7.5 V full scale adjustment of maximum speed preset will alter
the full scale reading from 4 V (anti-clockwise) to 9 V (clockwise)
55
Setpoint ramp output, 0-10 V, impedance 1 kΩ
54
Current output, 0-5 V for 0-100% of chosen range (S1, S2), 1 kΩ impedance
53
Zero speed relay driver output, maximum 100 mA,
switches to -24 V
52
Stall relay driver output, maximum 100 mA,
switches to -24 V
51
-24 V relay supply, 25 mA -
do not short
RL
internal
transistor
T52 or T53
external relay
coil 2K8
from T51