29
5. After loosening the blade, carefully
remove it by turning it and insert the
new blade.
6. Carefully tighten the new blade by
hand. Start a manual cleaning program-
me using the “Cleaning” button. The
blade fastens itself during the first uses.
Trouble shooting
Mila indicates problems using a signal beep and via the display.
E04
E01
E02
E03
1. There is no glass jar.
2. The water container is empty.
3. The lid is open or not properly closed.
4. The collection container must be
emptied.
If the device does not work properly, please check the following steps:
1. Check if the manual was followed precisely and correctly.
2. Check the following table for possible reasons.
3. Check if all fuses are working.
Problem
Solution
There is water underneath
the device.
Make sure that the water and collection containers are
closed and that the collection container has not spilled
over.
The mixing chamber/bla-
des are not clean after the
automatic self-cleaning
programme.
Add a drop of detergent and select the intensive clea-
ning mode.
Gently wipe off by hand with a damp cloth.