INSTALLATION
The TankJet
®
78M is easy to install. The TankJet 78M
connects to a supply tube with a simple retaining clip. There
are two different size options for inlet connections to the
TankJet 78M; ¾" & 1". The supply line should be standard
smooth bore 16 gauge (.065" thick) stainless steel tube of
the appropriate size. A 9/64" or 3.5mm hole should be drilled
through the supply tube according to the diagram below.
Slip the supply tube into the inlet of the unit, aligning the
holes. Insert the retaining clip and swing it down until it
locks. It should wrap around the neck of the inlet, but still fit
loosely.
The TankJet 78M unit will only operate properly in the
suspended vertical position (inlet at top).
NOTE: In order to maintain 3-A sanitary compliance, all
units intended for CIP must be mounted in the suspended
vertical position in order to ensure proper drainage. Other
orientations must be either returned to the suspended
vertical position or removed after operation and cleaned
out-of-place.
Inlet Size
“A”
3/4"
1/4" (6.35mm)
1"
3/8" (9.52mm)
A
OPERATION
Refer to drawings on pages 9 thru 11 for parts list.
Specifications
Inlet Connection:
3/4" or 1" slip-fit
Operating Pressure Range:
25 − 125 psi (1.7 - 8.3 bar)
Max. Operating Temp:
200°F (93°C)
Flow Capacity:
13 − 37 gpm (49.2 – 140.1 l/min)
Effective Cleaning/Dia.:
To 25 ft. (7.6 m) maximum
Installation Hole Dia.:
2.87" (3" Tri-Clamp Flange Connection)
Approximate Weight:
4.1 lbs. (1.9 kg)
Recommended Strainer:
50 mesh (not included)