![Spotwave Wireless SpotCell 100 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/spotwave-wireless/spotcell-100/spotcell-100_user-manual_1351213035.webp)
Spotwave Wireless Inc.
27
11.
Information
: Proper alignment rotation
Action
: Make sure the DDU is rotated once completely within the
area available for rotation, and then move through the same rotation
again. DDU alignment is based on optimizing the direction the
DDU is facing after initially establishing the range of signal available
by rotating the DDU in a circle. Once the DDU has been rotated in
a circle and established the level of signal available, it now sets a
threshold based on the surroundings to determine when the LED
will illuminate green. If the DDU is not pointing in a direction that
is within a certain range of the highest signal it encountered since
being in ‘Install’ mode, the LED will not turn green. Additionally,
the LED will not illuminate green if a minimum signal level is not
achieved during the initial rotation.