background image

11

Coarse mode: RED

Standard mode: GREEN

Fine mode: ORANGE

USING YOUR RECEIVER 

(continued)

OPERATION 

 

Powering on and off
•   To turn the receiver on, press the 

power button

All the LED lights will blink sequentially to indicate 

that the receiver is on. The 

plumb LED indicator

 

lights will show the battery status (see page 8). 

The 

detection mode LED indicator 

will illuminate 

to indicate the device is on.

•   The receiver will automatically enter into ‘standard’ 

detection mode.

•   To turn the receiver off, press and hold the 

power 

button 

until the LED lights flash. 

Detection mode
•   The detection mode can be changed between 

‘coarse’, ‘standard’ and ‘fine’ mode. 

•   Press  the 

detection mode button

 to cycle 

through the detection modes. The coloured LED 

indicators will display the detection mode setting  

(see illustration, right).

Содержание MMR-W300R

Страница 1: ...MMR W300R M A C H I N E M O U N T E D R E C E I V E R W I T H W I R E L E S S I N C A B D I S P L A Y I N S T R U C T I O N M A N U A L...

Страница 2: ...by qualified repair personnel Repairs service or maintenance performed by unqualified personnel will void the warranty Only approved and authorised service technicians can carry out warranty repairs...

Страница 3: ...the following items are included with your laser level If anything is missing please contact your retailer Spot on MMR W300R Suction mount Spot on ICD W300 Clamp Charger 2x Magnets Carry case 4x AA a...

Страница 4: ...4 RECEIVER OVERVIEW FRONT Charging port Mounting pads Clamps Antenna for radio transmission to ICD W300 Sensor panel...

Страница 5: ...rs Detection mode fine standard coarse Detection mode LED indicator Blade tilt bulldozer mode Excavator mode Wireless radio transmission indicators Wireless radio transmission Centre LED indicators Pl...

Страница 6: ...300R LCD screen Power Wireless radio transmission indicators Wireless radio transmission Centre LED indicators Blade tilt indicators bull dozer mode Elevation LED indicators Elevation LED indicators B...

Страница 7: ...7 IN CAB DISPLAY OVERVIEW DISPLAY SCREEN Power status Arrow indicator Arrow indicator Centre alignment Low power indicator Speaker indicator Detection mode...

Страница 8: ...below Charging the rechargeable battery pack Unscrew the cap on the charging port Align the pins on the charger and screw into place Plug into a power source The battery indicator progress will be sho...

Страница 9: ...t charger will void the warranty WARNING Do not attempt to access the battery pack Due to the weather sealing protection the in built battery pack is non user serviceable Only approved service technic...

Страница 10: ...directly to the machine mast diameter 40 50mm Connection via magnets To attach the receiver to a metal surface on the machinery replace the clamps with the included magnets Remove the nuts and washer...

Страница 11: ...status see page 8 The detection mode LED indicator will illuminate to indicate the device is on The receiver will automatically enter into standard detection mode To turn the receiver off press and h...

Страница 12: ...ion frequencies press and hold the wireless radio transmission button until the coloured LED light changes see illustration right Position the in cab display as desired where it can be observed by the...

Страница 13: ...he same channel The in cab display will duplicate the reading on the receiver For detailed set up of the in cab display see page 22 USING YOUR RECEIVER continued If there are multiple receivers in use...

Страница 14: ...tandard or fine The LED indicators will flash green to indicate centre alignment see illustration page 15 If the receiver cannot detect the beam the red LED lights will flash slowly in the direction o...

Страница 15: ...15 Laser line is centred Laser line is not centred Laser line is not centred...

Страница 16: ...power button and the excavator mode button to cycle between each mode coarse standard or fine The LED indicators will light up to display the detection mode setting see illustration right Release the...

Страница 17: ...ntred Fine 0 5 Standard 1 5 Coarse 2 5 Tilted Far Left Fine 1 Standard 3 Coarse 5 Tilted Far Right Fine 1 Standard 3 Coarse 5 Tilted Left Fine 0 6 0 9 Standard 1 6 2 9 Coarse 2 6 4 9 Tilted Right Fine...

Страница 18: ...cavator mode plumb When the receiver is mounted onto an arm of an excavator or backhoe it can be used to display if the arm is tilted away from or towards the cab and plumb position To activate excava...

Страница 19: ...mode is set to fine To change the selected mode press and hold the power button and the blade tilt mode button to cycle between each mode coarse standard or fine The LED indicators will light up to d...

Страница 20: ...indication cut Plumb height indication cut 20 Cut Laser line is 105 155mm below level Cut Laser line is 40 105mm below level Cut Fine 5 40mm below level Standard 10 40mm below level Coarse 20 40mm be...

Страница 21: ...height indication fill 21 Fill Laser line is 105 155mm above level Level Laser line is level as per detection mode Fine 5mm Standard 10mm Coarse 20mm Fill Fine 5 40mm above level Standard 10 40mm abov...

Страница 22: ...tteries according to polarity and use a screw driver to replace the battery compartment door SET UP Attaching via the magnets Use the magnets to attach the in cab display directly onto various magneti...

Страница 23: ...and reposition the angle of the device Tighten the adjustment knob to secure in place Standard detection The in cab display will duplicate the reading on the receiver Refer to page 14 for more inform...

Страница 24: ...ion of the blade Refer to page 16 for more information on blade tilt bulldozer mode The in cab display will duplicate the reading on the receiver see illustration below Excavator mode plumb When the r...

Страница 25: ...lease refer to the instruction manual for your laser level Check the laser and receiver are within operating range Check the line of sight and ensure there is no interference In cab unit not displayin...

Страница 26: ...es before storing the in cab display for extended periods Clean the instrument with a dry soft cloth after use in dusty damp or wet conditions before storing Handle with care and store and transport w...

Страница 27: ...ARRANTY PERIOD 1 The extended warranty is available on selected tools only 2 You may extend the warranty period for your tool to 7 years from the date of purchase This excludes batteries battery packs...

Страница 28: ...or compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not...

Страница 29: ...29 To assist you with any queries or technical questions please contact customer support Australia 1300 658 338 New Zealand 0800 367 527 CUSTOMER SUPPORT...

Страница 30: ...iver 245 x 384 x 92 In cab display 109 x 187 x 39 SPECIFICATIONS Product code 50530 Warranty 7 Years Accuracy Fine 5 Standard 10mm Coarse 20mm Laser class compatibility 2 Red 3 Red Operating temperatu...

Страница 31: ...31 NOTES...

Страница 32: ...www spoton com au...