Item # GEN3500DFI Portable Dual Fuel Invertor Generator  

 

 

 

                                                                                      

 

Powerful Voltage:

 

This generator produces powerful voltage, which can result in electrocution.

 

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). 

• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical 
system to this generator without a qualified electrician.

 

Doing so voids your warranty

.

 Such connections must isolate generator power from utility 

power and comply with local electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, 
which may result in serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when 
utility power is restored. 
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with some 

extension cords. 
• Keep generator dry and operate with dry hands. Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.).  
• Do not touch bare wires or outlets (receptacles). 
• Do not allow children or non-qualified persons to operate this generator. 

 

                                                                                       

 

Flammable Gasoline:

 

This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or even 

death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline. 

• Do not operate this generator near open flame. 
• Do not smoke near this generator. 

• Always operate this generator on a firm, level surface. 

Gasoline is highly flammable and explosive. Handling fuel can result in serious injury or burns. 

• Always shut down this generator before refueling. Refuel in a well-ventilated area. Keep heat, sparks and flame away while refueling and away 
from the location where gasoline is stored. Never refuel indoors where gasoline fumes may reach flames and/or sparks. 
• Allow this generator to cool for at least 2 minutes before removing the fuel tank cap. Loosen the cap slowly to relieve pressure in the fuel tank. 
Avoid spilling fuel. 

• Do not fill the fuel tank above the upper limit line. Gasoline may expand during operation. Do not fill to the top of the tank. 
• Always check for spilled gasoline and immediately wipe it up before starting this generator. 
• Empty the fuel tank before storing or transporting this generator. 
• Always handle fuel outdoors. 
• Before transporting, turn the fuel valve to the “OFF” position and disconnect the spark plug. 
 

                                                                                    

 

High Temperatures:

 

This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees 

Fahrenheit (65 Degrees Celsius).

 

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces. 

• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and 
before storing indoors. 
• Hot exhaust may ignite some materials. Keep flammable materials away from this generator. 
• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure. 
 

                                                                                     

 

Usage:

 

Consult a physician(s) before using this generator if using a pacemaker.

 Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. 
 

                                                                                     

 

Usage:

 

Prolonged exposure to high noise levels can be hazardous to hearing. 

Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running. 

 

                                                                                     

 

Usage:

 

Misuse of this generator can damage it or shorten its life.

 Use this generator only for its intended purpose. 

• Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved in 
an emergency. 
• Allow this generator to run for several minutes before connecting any electrical devices. 
• Promptly turn off any malfunctioning devices and disconnect them. 

• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator. 
• Do not turn on electrical devices until 

after 

they are connected to this generator. 

• Turn off all connected electrical devices before stopping this generator. 

 
 

Содержание GEN3500DFI

Страница 1: ...ior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT HAVE QUESTIONS OR PROBLEMS CONTACT CUSTOMER SERVICE FIRST BEFORE RETURNING THIS PRODUCT TO THE RE...

Страница 2: ...nd Propane Or Unleaded Gasoline with octane rating 87 or higher This portable generator is not for use with gasoline ethanol blends with over 15 ethanol Do not use E85 fuel 3 600 RPM Mobility Kit Not...

Страница 3: ...tep 1 Verify Oil Level 13 Step 2 Verify Gas Level 14 Step 3 Ground The Generator 14 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 17 USB Usage 17 AC Parallel Terminals 18 STOPP...

Страница 4: ...ian to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states exc...

Страница 5: ...rator s electricity does not feed back into the electric utility power lines WARNING Do not use this generator to provide power for emergency medical equipment or life support devices Carbon Monoxide...

Страница 6: ...l tank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel Do not fill the fuel tank above the upper limit line Gasoline may expand during operation Do not fill to the t...

Страница 7: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 7...

Страница 8: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...t all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Item List DC connector wires for charging 12 Volt automotive type...

Страница 10: ...uit Protector 9 Engine Power Switch 10 120 Volt AC Outlet 11 DC Circuit Protector 12 12 Volt DC Outlet 13 Grounding Terminal 14 120 Volt RV Outlet 15 Smart Throttle 16 LP gas inlet 17 Parallel Ports A...

Страница 11: ...START DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service lif...

Страница 12: ...el tank cap may be tight and difficult to unscrew 3 Slowly add fresh unleaded gasoline with an octane rating 87 or higher to the fuel tank Be careful not to fill the fuel tank above the upper limit li...

Страница 13: ...the previous section titled Using the Generator for the First Time of this manual If not review this section now Step 1 Verify Oil Level It is important to check the oil level in the engine crankcase...

Страница 14: ...refueling Do not overfill the fuel tank Always check for fuel spills and immediately wipe them up Spilled fuel is a fire hazard and causes environmental damage IMPORTANT Use only fresh UNLEADED gasol...

Страница 15: ...to the off position 4 Pull the choke lever towards you 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pu...

Страница 16: ...l have a total wattage less than or equal to the rated wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated...

Страница 17: ...r several minutes after it has been started before plugging in a USB cable for charging Engine Overload Indicator Light If the engine overload indicator light comes on the generator s wattage amperage...

Страница 18: ...ectrical rating for startup 1 Have both generators ready to operate 2 Plug in BOTH parallel cables FIRST If you attach black wire on left A and white wire on right B duplicate the same position on the...

Страница 19: ...00 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15 1800 3600 NR 150 100 65 NR 20 2400 4800 175 125 75 50 NR 25 3000 6000 150 100 60 NR NR 30 3600 7200 125 65 NR NR...

Страница 20: ...reduce air pollution Perform maintenance checks and procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool...

Страница 21: ...be changed after the first 20 hours of operation Subsequently the oil should be changed every 6 months or for every 100 hours of use or when the oil has become contaminated with water and or dirt To...

Страница 22: ...e spark plug If it is cracked and or chipped discard and install a new spark plug A F7RTC spark plug such as NGK BPR6ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap shoul...

Страница 23: ...Care section Turn the fuel valve to the off position Disconnect the spark plug Do not obstruct any ventilation openings Do not drop or strike this generator while moving it Store this generator in a...

Страница 24: ...off Pull the fuel line off The carburetor will slide off Turn the carburetor upside down and remove the 10mm bolt on the bottom of the bowl Remove the pin that holds the float on Pull the float up In...

Страница 25: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 25...

Страница 26: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 26 PARTS DIAGRAM...

Страница 27: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 27 PARTS DIAGRAM...

Страница 28: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 28 PARTS DIAGRAM Valve Assembly...

Страница 29: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 29 PARTS DIAGRAM...

Страница 30: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 30 PARTS LIST...

Страница 31: ...uled maintenance As the power equipment engine owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power equipment engine or a part has failed due to abuse negl...

Страница 32: ...repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of Buffalo Corp 10 Add on or modified parts that are not exempted by the Air Resources Board...

Отзывы: