Sportsman GEN3500DFI Скачать руководство пользователя страница 15

Item # GEN3500DFI Portable Dual Fuel Invertor Generator  

 

 

 

15 

 

STARTING THE GENERATOR 

 

STOP!

 

Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been 

correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for 
customer service. 

 

                                                                                           

  

Disconnect all electrical loads from this generator before attempting to start.

 

 
To start this generator: 
1. Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine. 

2. Confirm that this generator is properly grounded. (See “Ground the Generator” section of this manual.) 

3A. If using gasoline, turn the fuel switch to the “on” position. 

3B. If using propane, turn the fuel switch to the “off” position.  

4. Pull the choke lever towards you.  

5. Set the engine switch to the “on” position. 

6. Slowly pull on the recoil starter handle, shown in Figure 4, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the 

cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back. 

7. If the engine fails to start, repeat step 6.  

NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting again. If problems persist,  

call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.

 

8. 

Once the engine has started, GRADUALLY push the choke lever until the engine levels off. Then let the engine run 

approximately 5 minutes BEFORE adding appliances or tools.

 

 
 

Choke Rod 

 

The choke is used to provide an enriched fuel mixture when starting a cold engine. 
It can be opened and closed by operating the choke rod manually.  
 

 

 

 
 
 

 
 
 
 
 

 
 
 
 
 
 

 
 

Figure 4 
The Recoil Start is located on the left  
side of the generator.

 

Choke OUT/OFF 
To Start 

Choke IN/ON 
To Run 

Содержание GEN3500DFI

Страница 1: ...ior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT HAVE QUESTIONS OR PROBLEMS CONTACT CUSTOMER SERVICE FIRST BEFORE RETURNING THIS PRODUCT TO THE RE...

Страница 2: ...nd Propane Or Unleaded Gasoline with octane rating 87 or higher This portable generator is not for use with gasoline ethanol blends with over 15 ethanol Do not use E85 fuel 3 600 RPM Mobility Kit Not...

Страница 3: ...tep 1 Verify Oil Level 13 Step 2 Verify Gas Level 14 Step 3 Ground The Generator 14 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 17 USB Usage 17 AC Parallel Terminals 18 STOPP...

Страница 4: ...ian to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states exc...

Страница 5: ...rator s electricity does not feed back into the electric utility power lines WARNING Do not use this generator to provide power for emergency medical equipment or life support devices Carbon Monoxide...

Страница 6: ...l tank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel Do not fill the fuel tank above the upper limit line Gasoline may expand during operation Do not fill to the t...

Страница 7: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 7...

Страница 8: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...t all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Item List DC connector wires for charging 12 Volt automotive type...

Страница 10: ...uit Protector 9 Engine Power Switch 10 120 Volt AC Outlet 11 DC Circuit Protector 12 12 Volt DC Outlet 13 Grounding Terminal 14 120 Volt RV Outlet 15 Smart Throttle 16 LP gas inlet 17 Parallel Ports A...

Страница 11: ...START DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service lif...

Страница 12: ...el tank cap may be tight and difficult to unscrew 3 Slowly add fresh unleaded gasoline with an octane rating 87 or higher to the fuel tank Be careful not to fill the fuel tank above the upper limit li...

Страница 13: ...the previous section titled Using the Generator for the First Time of this manual If not review this section now Step 1 Verify Oil Level It is important to check the oil level in the engine crankcase...

Страница 14: ...refueling Do not overfill the fuel tank Always check for fuel spills and immediately wipe them up Spilled fuel is a fire hazard and causes environmental damage IMPORTANT Use only fresh UNLEADED gasol...

Страница 15: ...to the off position 4 Pull the choke lever towards you 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pu...

Страница 16: ...l have a total wattage less than or equal to the rated wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated...

Страница 17: ...r several minutes after it has been started before plugging in a USB cable for charging Engine Overload Indicator Light If the engine overload indicator light comes on the generator s wattage amperage...

Страница 18: ...ectrical rating for startup 1 Have both generators ready to operate 2 Plug in BOTH parallel cables FIRST If you attach black wire on left A and white wire on right B duplicate the same position on the...

Страница 19: ...00 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15 1800 3600 NR 150 100 65 NR 20 2400 4800 175 125 75 50 NR 25 3000 6000 150 100 60 NR NR 30 3600 7200 125 65 NR NR...

Страница 20: ...reduce air pollution Perform maintenance checks and procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool...

Страница 21: ...be changed after the first 20 hours of operation Subsequently the oil should be changed every 6 months or for every 100 hours of use or when the oil has become contaminated with water and or dirt To...

Страница 22: ...e spark plug If it is cracked and or chipped discard and install a new spark plug A F7RTC spark plug such as NGK BPR6ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap shoul...

Страница 23: ...Care section Turn the fuel valve to the off position Disconnect the spark plug Do not obstruct any ventilation openings Do not drop or strike this generator while moving it Store this generator in a...

Страница 24: ...off Pull the fuel line off The carburetor will slide off Turn the carburetor upside down and remove the 10mm bolt on the bottom of the bowl Remove the pin that holds the float on Pull the float up In...

Страница 25: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 25...

Страница 26: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 26 PARTS DIAGRAM...

Страница 27: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 27 PARTS DIAGRAM...

Страница 28: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 28 PARTS DIAGRAM Valve Assembly...

Страница 29: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 29 PARTS DIAGRAM...

Страница 30: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 30 PARTS LIST...

Страница 31: ...uled maintenance As the power equipment engine owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power equipment engine or a part has failed due to abuse negl...

Страница 32: ...repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of Buffalo Corp 10 Add on or modified parts that are not exempted by the Air Resources Board...

Отзывы: