Sportsman GEN3500DFI Скачать руководство пользователя страница 18

Item # GEN3500DFI Portable Dual Fuel Invertor Generator  

 

 

 

18 

Turning Off Generators while in Parallel Function 

1. Disconnect or turn off item plugged into parallel receptacle. 
2. Turn off both generators. 
3. Carefully disconnect the parallel cables from both generators 

 

AC PARALLEL TERMINALS 

 

Located just above the RV Outlet, the generator’s Parallel Outlets enable a user to run two GEN3500DFI generator’s simultaneously. This 
operation requires special cables (sold separately). 

 

The parallel port terminals are used with a parallel kit (sold separately). It will allow two generators to be linked to increase output. The black 

and white wire connections are non-polarized and can be inserted into either the left or right ports. 
NOTE: Do not disconnect cables while the generator is running. The generator or the load may be damaged. 
NOTE: Only connect two identical Inverter Generators together using a Parallel Kit. 

 

 

 

 

 

 

 

 

 

 

Before connecting an appliance to a generator, make sure that the appliance is in good working order and that its  electrical rating does not 

exceed that of the outlet. Most appliances require more than their electrical rating for  startup. 

1. 

Have both generators ready to operate. 

2. 

Plug in BOTH parallel cables FIRST. If you attach black wire on left A and white wire on right B, duplicate the same position on the 

opposite generator. 

3. 

Attach both ground connections on both control panels.  

4. 

Power up each generator, with the Smart Throttle switch in off position. 

5. 

After running a few minutes, plug in appliances into RV cable or outlet on control panel. Make sure appliances are off. 

6. 

Gradually turn on each appliance after making sure both generators are in normal running (the output indicator LED (green)  flashes. 

 
 

Note: 

The required power of the electrical appliance connected to the parallel outlet cannot exceed the rated output  

of paralleled generators.  

 
 
 

 
 
 
 
 

 
 
 
 
 
 

 
 
 
 

 

Do not pair more than 2 generators. 
Only use the Sportsman Generator parallel output cable for parallel operation (sold separately). 

 

You can use the outlets on the control panel of the generator while operating in parallel. Do not exceed combined 
load on all outlets 20 amps. 

 

If parallel cables are not properly connected to the generators, one or both generators can be damaged and
could explode. 

 

DO NOT connect or disconnect the parallel connection cable from the control panel while the generators are 
running. Turn off both generators before disconnecting parallel cables. 

Содержание GEN3500DFI

Страница 1: ...ior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT HAVE QUESTIONS OR PROBLEMS CONTACT CUSTOMER SERVICE FIRST BEFORE RETURNING THIS PRODUCT TO THE RE...

Страница 2: ...nd Propane Or Unleaded Gasoline with octane rating 87 or higher This portable generator is not for use with gasoline ethanol blends with over 15 ethanol Do not use E85 fuel 3 600 RPM Mobility Kit Not...

Страница 3: ...tep 1 Verify Oil Level 13 Step 2 Verify Gas Level 14 Step 3 Ground The Generator 14 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 17 USB Usage 17 AC Parallel Terminals 18 STOPP...

Страница 4: ...ian to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states exc...

Страница 5: ...rator s electricity does not feed back into the electric utility power lines WARNING Do not use this generator to provide power for emergency medical equipment or life support devices Carbon Monoxide...

Страница 6: ...l tank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel Do not fill the fuel tank above the upper limit line Gasoline may expand during operation Do not fill to the t...

Страница 7: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 7...

Страница 8: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...t all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Item List DC connector wires for charging 12 Volt automotive type...

Страница 10: ...uit Protector 9 Engine Power Switch 10 120 Volt AC Outlet 11 DC Circuit Protector 12 12 Volt DC Outlet 13 Grounding Terminal 14 120 Volt RV Outlet 15 Smart Throttle 16 LP gas inlet 17 Parallel Ports A...

Страница 11: ...START DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service lif...

Страница 12: ...el tank cap may be tight and difficult to unscrew 3 Slowly add fresh unleaded gasoline with an octane rating 87 or higher to the fuel tank Be careful not to fill the fuel tank above the upper limit li...

Страница 13: ...the previous section titled Using the Generator for the First Time of this manual If not review this section now Step 1 Verify Oil Level It is important to check the oil level in the engine crankcase...

Страница 14: ...refueling Do not overfill the fuel tank Always check for fuel spills and immediately wipe them up Spilled fuel is a fire hazard and causes environmental damage IMPORTANT Use only fresh UNLEADED gasol...

Страница 15: ...to the off position 4 Pull the choke lever towards you 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pu...

Страница 16: ...l have a total wattage less than or equal to the rated wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated...

Страница 17: ...r several minutes after it has been started before plugging in a USB cable for charging Engine Overload Indicator Light If the engine overload indicator light comes on the generator s wattage amperage...

Страница 18: ...ectrical rating for startup 1 Have both generators ready to operate 2 Plug in BOTH parallel cables FIRST If you attach black wire on left A and white wire on right B duplicate the same position on the...

Страница 19: ...00 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15 1800 3600 NR 150 100 65 NR 20 2400 4800 175 125 75 50 NR 25 3000 6000 150 100 60 NR NR 30 3600 7200 125 65 NR NR...

Страница 20: ...reduce air pollution Perform maintenance checks and procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool...

Страница 21: ...be changed after the first 20 hours of operation Subsequently the oil should be changed every 6 months or for every 100 hours of use or when the oil has become contaminated with water and or dirt To...

Страница 22: ...e spark plug If it is cracked and or chipped discard and install a new spark plug A F7RTC spark plug such as NGK BPR6ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap shoul...

Страница 23: ...Care section Turn the fuel valve to the off position Disconnect the spark plug Do not obstruct any ventilation openings Do not drop or strike this generator while moving it Store this generator in a...

Страница 24: ...off Pull the fuel line off The carburetor will slide off Turn the carburetor upside down and remove the 10mm bolt on the bottom of the bowl Remove the pin that holds the float on Pull the float up In...

Страница 25: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 25...

Страница 26: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 26 PARTS DIAGRAM...

Страница 27: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 27 PARTS DIAGRAM...

Страница 28: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 28 PARTS DIAGRAM Valve Assembly...

Страница 29: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 29 PARTS DIAGRAM...

Страница 30: ...Item GEN3500DFI Portable Dual Fuel Invertor Generator 30 PARTS LIST...

Страница 31: ...uled maintenance As the power equipment engine owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power equipment engine or a part has failed due to abuse negl...

Страница 32: ...repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of Buffalo Corp 10 Add on or modified parts that are not exempted by the Air Resources Board...

Отзывы: