Sportsman GEN2000LP Скачать руководство пользователя страница 5

GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual 

 

 

5

 

 

Legal Requirements: 
Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended 

use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators 

to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site. 

 
 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

STOP!

 

Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on 
this generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time. 

 

                                                                        

 

Carbon Monoxide Gas:

 When in operation, the exhaust from this generator contains poisonous carbon 

monoxide gas. Carbon monoxide gas is both odorless and colorless AND may be present even if you do not 
see or smell gas. Breathing this poison gas can lead to headaches, dizziness, drowsiness, loss of 

consciousness and eventually death. 

• Use this generator ONLY outdoors in non-confined areas. 

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. 
 

                                                                           

 

Chemicals:

 According to the State of California, the exhaust from this generator contains chemicals known to 

cause cancer, birth defects, or other reproductive harm. 
 

                                                                          

 

Propane (LPG):

 This generator may emit highly flammable and explosive vapors, which can cause severe 

burns or even death. A nearby open flame can lead to an explosion even if not directly in contact the fuel. 

• Do not operate this generator near open flame. 
• Always operate this generator on a firm, level surface. 

This fuel is highly flammable and explosive. Handling fuel can result in serious injury or burns. 

• Before starting the generator, inspect your LPG tank and NG pipeline and valve for damage or leaks, attach only 

approved tanks that have been properly filled by an approved station, DO NOT light or smoke cigarette.  
Replace the hose at the first sign of a leak or if age-cracking becomes apparent.

 

• Always handle propane fuel and generator outdoors. 

• Before transporting, turn the fuel valve to the "off" position and disconnect the spark plug. 
 

                                                                      

 

Powerful Voltage:

 This generator produces powerful voltage, which can result in electrocution. 

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). 
• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER 

connect a building electrical system to this generator without a qualified electrician. Doing so voids your warranty. 

Such connections must isolate generator power from utility power and comply with local electrical laws and codes. 
Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious 

injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when 

utility power is restored. 

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this 

generator dry and operate it with dry hands. 
• Do not touch bare wires or outlets (receptacles). 

• Do not allow children or non-qualified persons to operate this generator. 
  

Содержание GEN2000LP

Страница 1: ...is product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CONTACT CUSTOMER SERV...

Страница 2: ...this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free at 1 866 460 9436 email address info buffalotools com and you will be instructed on where to take the engine for warran...

Страница 3: ...Step 3 Ground The Generator 14 Subsequent Use Of This Generator 14 Step 1 Verify Oil Level 14 Step 3 Ground The Generator 15 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 18 ST...

Страница 4: ...rstand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates...

Страница 5: ...o an explosion even if not directly in contact the fuel Do not operate this generator near open flame Always operate this generator on a firm level surface This fuel is highly flammable and explosive...

Страница 6: ...city of this generator Do not turn on electrical devices until after they are connected to this generator Turn off all connected electrical devices before stopping this generator Usage Consult a physi...

Страница 7: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 7...

Страница 8: ...000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this gener...

Страница 9: ...tts 1350 Running Watts Portable LP Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RET...

Страница 10: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 10 GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator...

Страница 11: ...r can damage your generator and your electrical devices and will void your warranty To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy wire b...

Страница 12: ...correct quantity of oil is equal to the oil capacity of the engine crankcase and is 14 fluid oz for this model GEN2000LP 2000 Surge Watts 1350 Running Watts Portable LP Generator Add the correct quan...

Страница 13: ...ints should be tightly secured before operating the machine Check the joints and gas hose for leakage or breaks replace the damaged joints and hose if necessary Check the gas pipeline for any damages...

Страница 14: ...fy Oil Level Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil it is important to check the oil level in the engine crankcase before each use to...

Страница 15: ...en correctly completed If unsure about how to perform any of these steps call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Disconnect all electrical loads from this generat...

Страница 16: ...less than or equal to the rated wattage for the generator i e no more than 2000 for this Model GEN2000 2000 Surge Watts 1350 Running Watts Portable Generator This generator can run at its surge wattag...

Страница 17: ...Figure 8 for an illustration of these outlets Even though this Model GEN2000LP Portable LP Generator has an overall rated wattage of 2000 do not attempt to draw more than 1350 Watts 20 A from any ONE...

Страница 18: ...the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 Start this generat...

Страница 19: ...ark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this generator becomes dirty the exterior can b...

Страница 20: ...d on the crankcase underneath the oil filler dipstick cap as illustrated in Figure 12 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 10 mm hex wrench...

Страница 21: ...sh the sponge like elements in household detergent and warm water Do not use gasoline or a flammable solvent 5 Allow the sponge like elements to dry thoroughly 6 Soak the dry sponge like elements in e...

Страница 22: ...e moving it A hot engine and exhaust system can burn you and ignite some materials Disconnect the battery used for the electric start feature of this generator first disconnecting the black cable and...

Страница 23: ...ices Disconnect any faulty or short circuited electrical loads Generator runs but does not support all connected electrical devices Air filter is dirty Clean or replace air filter Loose wiring harness...

Страница 24: ...Wattage W 2000 Surge Wattage W 1350 Rated Voltage V 120 Rated Amperage 9A at 120 V Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breaker Amperage A 10 Engine Approvals EPA Engine...

Страница 25: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 25 PARTS DIAGRAM...

Страница 26: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 26 PARTS DIAGRAM...

Страница 27: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 27 201109...