Device Requirements 

Max. Cord Length (ft) by Wire Gauge 

Amps 

Watts (120V) 

Watts (240V) 

#8 wire  #10 wire 

#12 wire 

#14 wire 

#16 wire 

2.5  300 

600  NR 1000 600 375 250 

600 

1200  NR 500 300 200 125 

7.5  900 

1800  NR 350 200 125 100 

10  1200 

2400  NR 250 150 100  50 

15 1800  3600 NR 

150 

100 

65 NR 

20 2400  4800 175 

125 

75 50 NR 

25 3000  6000 150 

100 

60 NR 

NR 

30  3600 

7200  125 65  NR NR NR 

40  4800 

9600  90 NR NR NR NR 

NR = Not Recommended. 

 
Figure 9 - Maximum Extension Cord Lengths by Power Requirement 

 

DC Usage 

 
                                                                                     

 

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet. 
 
                                                                                     

  

Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator. 
 

                                                                                     

 

Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and 
smoking materials away from the battery.
 
 

 

To connect 12 Volt batteries to the DC outlet: 
1. Connect the red charging wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery. 

2. Connect the plug end of the wire to the 12V DC outlet on this generator. 

3. Start this generator. 

4. When disconnecting, always disconnect the wires from this generator first to avoid a spark. 
 

                                                                                         

 

Storage batteries emit highly explosive hydrogen gas when charged. 
Batteries also contain acid, which can cause severe chemical burns. 

• Do not allow open flames or cigarettes nearby for several minutes after charging a battery. 

• Always wear protective goggles and rubber gloves when charging a battery. 

 

• If battery acid gets on the skin, flush with water. 

 

• If battery acid gets in the eyes, flush with water and immediately call a physician. 

 

• If battery acid is swallowed, drink large quantities of milk and immediately call a physician. 

 

 

STOPPING THE GENERATOR 

 

To stop this generator: 
1. Turn off all connected electrical devices and then unplug them. 

2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 

3. Turn the engine switch “off”. 

4. Turn the fuel valve to the “off” position. 
 

                                                                                         

   

Allow this generator to cool down before touching areas that become hot during operation. 
 

Содержание GEN2000LP

Страница 1: ...is product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CONTACT CUSTOMER SERV...

Страница 2: ...this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free at 1 866 460 9436 email address info buffalotools com and you will be instructed on where to take the engine for warran...

Страница 3: ...Step 3 Ground The Generator 14 Subsequent Use Of This Generator 14 Step 1 Verify Oil Level 14 Step 3 Ground The Generator 15 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 18 ST...

Страница 4: ...rstand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates...

Страница 5: ...o an explosion even if not directly in contact the fuel Do not operate this generator near open flame Always operate this generator on a firm level surface This fuel is highly flammable and explosive...

Страница 6: ...city of this generator Do not turn on electrical devices until after they are connected to this generator Turn off all connected electrical devices before stopping this generator Usage Consult a physi...

Страница 7: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 7...

Страница 8: ...000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this gener...

Страница 9: ...tts 1350 Running Watts Portable LP Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RET...

Страница 10: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 10 GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator...

Страница 11: ...r can damage your generator and your electrical devices and will void your warranty To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy wire b...

Страница 12: ...correct quantity of oil is equal to the oil capacity of the engine crankcase and is 14 fluid oz for this model GEN2000LP 2000 Surge Watts 1350 Running Watts Portable LP Generator Add the correct quan...

Страница 13: ...ints should be tightly secured before operating the machine Check the joints and gas hose for leakage or breaks replace the damaged joints and hose if necessary Check the gas pipeline for any damages...

Страница 14: ...fy Oil Level Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil it is important to check the oil level in the engine crankcase before each use to...

Страница 15: ...en correctly completed If unsure about how to perform any of these steps call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Disconnect all electrical loads from this generat...

Страница 16: ...less than or equal to the rated wattage for the generator i e no more than 2000 for this Model GEN2000 2000 Surge Watts 1350 Running Watts Portable Generator This generator can run at its surge wattag...

Страница 17: ...Figure 8 for an illustration of these outlets Even though this Model GEN2000LP Portable LP Generator has an overall rated wattage of 2000 do not attempt to draw more than 1350 Watts 20 A from any ONE...

Страница 18: ...the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 Start this generat...

Страница 19: ...ark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this generator becomes dirty the exterior can b...

Страница 20: ...d on the crankcase underneath the oil filler dipstick cap as illustrated in Figure 12 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 10 mm hex wrench...

Страница 21: ...sh the sponge like elements in household detergent and warm water Do not use gasoline or a flammable solvent 5 Allow the sponge like elements to dry thoroughly 6 Soak the dry sponge like elements in e...

Страница 22: ...e moving it A hot engine and exhaust system can burn you and ignite some materials Disconnect the battery used for the electric start feature of this generator first disconnecting the black cable and...

Страница 23: ...ices Disconnect any faulty or short circuited electrical loads Generator runs but does not support all connected electrical devices Air filter is dirty Clean or replace air filter Loose wiring harness...

Страница 24: ...Wattage W 2000 Surge Wattage W 1350 Rated Voltage V 120 Rated Amperage 9A at 120 V Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breaker Amperage A 10 Engine Approvals EPA Engine...