Sportsman GEN2000LP Скачать руководство пользователя страница 2

GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual 

 

 

2

Model GEN2000LP 2000 Surge Watts / 1350 Running Watts  
LPG (Liquid Propane) Portable Generator 

 

This unit is a LPG driven generator.   

 

 

FEATURES: 

• 2000 Surge Output  

• 1350 Running Watts 
• 120 Volt Operation  

• 2.8 HP Engine, 4 Stroke OHV  

• Air Cooled 

• Recoil Start 

• Spark Arrestor 
• UL Listed Electrical Components 

• Engine Shut Off Switch 

• 1-12V DC Outlet 

• 1-120V Outlets  
• EPA –approved 

• Run time = 12 hrs @ 50% load per 20 lbs of LPG fuel 

• Fuel type- Liquid Propane Gas Only 

• Propane Tank Not Included  
• Decibel Rating: < 65 db 

 

 

 

THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 . 

 

The emission-related warranty is valid for two (2) years. Keep the purchase receipt and mail in the product registration card for proof of purchase.  

NB Corp limits emission-related warranty repairs to authorized service centers for owners located within 100 miles of an authorized service center. 

For owners located more than 100 miles from an authorized service center, NB Corp will, in its sole discretion, either pay for shipping costs to and 
from an authorized service center, provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made 

at a local non-authorized service center. The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude 

areas identified in 40 CFR part 1068, Appendix III. 

 
To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address 

[email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your 

receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generators damaged or 

affected by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed 
and any other modifications or abuse.  

 

90 DAY LIMITED WARRANTY   

 
Generators are warranted to be free from defects in materials and workmanship for a period of 90 days from date of original purchase. NB Corp. is 

not liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 90 days as 

stated, or as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential 

damages. Some states do not allow limitation on the length of an implied warranty. NB Corp will repair or replace, at its discretion, any part that is 
proven to be defective in materials or workmanship under normal use during the 90 day warranty period. Warranty repairs or replacements will be 

made without charge for parts or labor. Parts replaced during warranty repairs will be considered as part of the original product and will have the 

same warranty period as the original product.  

 
 

This warranty gives you specific legal rights, and you may have other rights that vary from state to state. 

 

Содержание GEN2000LP

Страница 1: ...is product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CONTACT CUSTOMER SERV...

Страница 2: ...this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free at 1 866 460 9436 email address info buffalotools com and you will be instructed on where to take the engine for warran...

Страница 3: ...Step 3 Ground The Generator 14 Subsequent Use Of This Generator 14 Step 1 Verify Oil Level 14 Step 3 Ground The Generator 15 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 18 ST...

Страница 4: ...rstand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates...

Страница 5: ...o an explosion even if not directly in contact the fuel Do not operate this generator near open flame Always operate this generator on a firm level surface This fuel is highly flammable and explosive...

Страница 6: ...city of this generator Do not turn on electrical devices until after they are connected to this generator Turn off all connected electrical devices before stopping this generator Usage Consult a physi...

Страница 7: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 7...

Страница 8: ...000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this gener...

Страница 9: ...tts 1350 Running Watts Portable LP Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RET...

Страница 10: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 10 GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator...

Страница 11: ...r can damage your generator and your electrical devices and will void your warranty To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy wire b...

Страница 12: ...correct quantity of oil is equal to the oil capacity of the engine crankcase and is 14 fluid oz for this model GEN2000LP 2000 Surge Watts 1350 Running Watts Portable LP Generator Add the correct quan...

Страница 13: ...ints should be tightly secured before operating the machine Check the joints and gas hose for leakage or breaks replace the damaged joints and hose if necessary Check the gas pipeline for any damages...

Страница 14: ...fy Oil Level Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil it is important to check the oil level in the engine crankcase before each use to...

Страница 15: ...en correctly completed If unsure about how to perform any of these steps call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Disconnect all electrical loads from this generat...

Страница 16: ...less than or equal to the rated wattage for the generator i e no more than 2000 for this Model GEN2000 2000 Surge Watts 1350 Running Watts Portable Generator This generator can run at its surge wattag...

Страница 17: ...Figure 8 for an illustration of these outlets Even though this Model GEN2000LP Portable LP Generator has an overall rated wattage of 2000 do not attempt to draw more than 1350 Watts 20 A from any ONE...

Страница 18: ...the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 Start this generat...

Страница 19: ...ark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this generator becomes dirty the exterior can b...

Страница 20: ...d on the crankcase underneath the oil filler dipstick cap as illustrated in Figure 12 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 10 mm hex wrench...

Страница 21: ...sh the sponge like elements in household detergent and warm water Do not use gasoline or a flammable solvent 5 Allow the sponge like elements to dry thoroughly 6 Soak the dry sponge like elements in e...

Страница 22: ...e moving it A hot engine and exhaust system can burn you and ignite some materials Disconnect the battery used for the electric start feature of this generator first disconnecting the black cable and...

Страница 23: ...ices Disconnect any faulty or short circuited electrical loads Generator runs but does not support all connected electrical devices Air filter is dirty Clean or replace air filter Loose wiring harness...

Страница 24: ...Wattage W 2000 Surge Wattage W 1350 Rated Voltage V 120 Rated Amperage 9A at 120 V Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breaker Amperage A 10 Engine Approvals EPA Engine...

Страница 25: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 25 PARTS DIAGRAM...

Страница 26: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 26 PARTS DIAGRAM...

Страница 27: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 27 201109...

Отзывы: