Problem
Solution
The pulse rate values are skipping/ are
displayed irregularly.
•
Measuring the pulse rate using hand
pulse sensors is naturally not as
precise as measuring using a chest
strap. It depends on the skin structure
(thickness), sweat, etc. The hand
pulse sensors (or the device) can
become statically charged during
workout due to friction, disrupting the
heart rate measurement as a result.
TIP:
Placing a special anti-static mat
underneath can help prevent static
charge.
•
Furthermore, the following factors can
affect the pulse rate measurement
(both via hand pulse sensors or chest
strap): Mobile phones, TVs, radios,
power lines, transmission towers,
electrified railway lines, etc. Make
sure the surrounding of the device is
free from such interfering sources.
Remove the pedal crank and side covers
to perform repairs inside the device.
•
Unscrew the nut (54) that secures
the crank against the axis. Then
screw the puller (not included) into
the thread of the pedal crank, fix the
pin to the pedal axis, and then pull off
the crank by screwing the pin further
in. To remove the side covers, loosen
the Phillips screws located in the
recesses.