REPAIR MANUAL
Page: 13
14. FAULT CODES
A repair fault is signaled by the continuous rotating of the Program Knob and the flashing of the Door Locked LED. The Fault Code is
determined by counting the sequence of individual flashes of the LED (2 flashes = F2). The LED will flash the Fault Code sequence
and then delay for approximately eight (8) seconds, repeating the Fault Code sequence and eight second delay continually.
TECH NOTE: The unit can be turned off without harm and the Fault Code sequence will repeat when power is reapplied.
F1. Triac
Short
Replace Control Board.
F2. Main
Motor
Check Main Motor connections.
Replace Main Motor.
Or, replace Control Board.
F3. NTC (Water Temp) Open / Short
Check wiring continuity to Control Board.
Replace
NTC.
Or, replace Control Board.
F4. Pressure
Switch
Check wiring continuity to Control Board.
Replace
Pressure
Switch.
Or, replace Control Board.
F5. Blocked Drain Motor or Pressure Switch shorted in Empty position
Check Drain Hose.
Check Drain Motor clean out for obstruction.
Check voltage at Drain Motor.
Check Pressure Switch wiring continuity.
Replace Drain Motor / Pressure Switch.
Or, replace Control Board.
F6. Program
Selector
Check wiring continuity to Control Board.
Replace
Program
Selector.
Or, replace Control Board.
F7. Not
Used
F8. Pressure Switch Shorted in Full Position
Check Pressure Switch wiring continuity.
Or, replace Pressure Switch.
Or, replace Control Board.
F9. Control Board Error
Incorrect version of Control Board or EEPROM.
Change Control Board and EEPROM.
F10. Pressure
Switch
Shorted
Check wiring continuity to Control Board.
Replace
Pressure
Switch.
Or, replace Control Board.
F11. Drain
Motor
Check wiring continuity to Control Board.
Check Drain Motor clean out for obstruction.
Voltage check at Drain Motor.
Check Pressure Switch.
Replace
Drain
Motor.
Or, replace Control Board.
F12. Not
Used
F13 - F16 Apply Only to AWD 120
F13. NTC (Dryer Temp) Open / Short
Check wiring continuity to Control Board.
Replace
NTC.
Or, replace Control Board.
F14. Dryer Heating Element is Open
Check Dryer Heating Element continuity.
Check wiring from Element to Control Board.
Replace
Heating
Element.
Or, replace Control Board
F15. Dryer Heating Element Relay Shorted
Check Dryer Heating Element continuity.
Check wiring from Element to Control Board.
Replace Control Unit.
F16. Not
Used
AW 120 / AW 122 / AW 125
AWD 120 / AWD 121 / AWD 129