SPL Transient Designer 2715 Скачать руководство пользователя страница 4

4

RackPack: Transient Designer

Important Security Information

Please note and retain this information. Carefully read and follow all 
of the safety and operating instructions before you use the machine. 
Be doubly careful to follow all warnings and special safety instructions 
noted in this manual and on the unit. The following information refers 
to modules built into the RackPack frame.

Connections: 

Only  use  the  connections  as  described.  Other  connec-

tions can lead to health risks and equipment damage.

Water And Humidity:

 Do NOT use this machine anywhere near water 

(for example near a wash basin or bath, in a damp cellar, near swim-
ming pools, or the like). In such cases there is an extremely high risk of 
fatal electrical shocks!

Insertion Of Foreign Objects Or Fluids: 

NEVER allow a foreign object 

through any of the machine‘s chassis openings. You can easily come 
into contact with dangerous voltage or cause a damaging short circuit. 
NEVER allow any fluids to be spilled or sprayed on the machine. Such 
actions can lead to dangerous electrical shocks or fire! 

OPENING THE DEVICE: Open the device only to fit or exchange mod-
ules. The fitting and/or exchange of modules should only be carried 
out  by  qualified  persons.  In  the  light  of  possible  physical  damage 
or  injuries  any  manipulation  is  at  your  own  risk.  In  order  to  avoid 
any  residual  voltage,  the  device  should  be  disconnected  from  any 
power source at least 5 minutes prior to opening it. If you handle the 
device  improperly  or  ignore  the  manual  (part  of  the  delivery  of  the 
RackPack  frame)  you  risk  to  damage  the  device  or  expose  yourself 
to an electric shock. In these cases SPL electronics GmbH denies any 
responsibility.

Electrical  Power:

  Run  this  machine  ONLY  from  sources  which  can 

provide proper power at the prescribed rating. When in doubt about 
a source, contact your dealer or a professional electrician. To be sure 
you have isolated the machine, do so by disconnecting the power cord 
from your wall connection. Be sure that the power cord plug is always 
accessible. When not using the machine for a longer period, make sure 
to unplug it from your wall power socket. 

Power Cord Protection:

 Make sure that your power cord is arranged to 

avoid  being  stepped  on  or  any  kind  of  crimping  and  damage  related 
to such event. Do not allow any equipment or furniture to crimp this 
power cord.

Power  Connection  Overloads: 

Avoid  any  kind  of  overload  in  connec-

tions to wall sockets, extension or splitter power cords. Always keep 
manufacturer warnings and instructions in mind. Overloads create fire 
hazards and risk of dangerous shocks!

Содержание Transient Designer 2715

Страница 1: ...ic Envelope Processor RackPack Module Model 2715 LINK ON T R A N SIENT DESIGNER 2 7 1 5 dB dB S I G O V L 2 0 1 5 1 0 6 3 0 1 2 3 5 6 SUSTAIN 2 4 1 8 1 2 6 3 0 3 6 1 2 1 8 2 4 OUTPUT GAIN ATTACK 1 5 1...

Страница 2: ...io Signal Processor Product RackPack Transient Designer Model 2715 Compliance Engineer Wolfgang Neumann Test Basis EN50081 1 1992 EN50082 1 1992 EN60065 1993 EN61000 3 3 1995 EN60065 2002 EN55013 2001...

Страница 3: ...r Link Mode 12 Signal LED Overload LED 13 Applications 14 Drums Percussion 14 Drums Ambience 15 Guitars The Transfer Of Dynamic Structures 16 Bass Staccato vs Legato 17 The Re Invention Of Reverb 17 B...

Страница 4: ...d out by qualified persons In the light of possible physical damage or injuries any manipulation is at your own risk In order to avoid any residual voltage the device should be disconnected from any p...

Страница 5: ...achine and immediately contact a qualified technician when you think repairs are needed or when moisture or foreign objects may accidentally have gotten in to the housing or in cases when the machine...

Страница 6: ...U AWARE OF IMPORTANT OPERATIONAL ADVICE AND OR WARNINGS THAT MUST BE FOLLOWED BE ESPECIALLY ATTENTIVE TO THESE AND ALWAYS FOLLOW THE ADVICE THEY GIVE The symbol of a lamp directs your attention to exp...

Страница 7: ...channel are required to allow the user to completely reshape the attack and sustain characteristics of a sound attack can be amplified or attenuated by up to 15dB while sustain can be amplified or at...

Страница 8: ...nsient Designer Rear Panel Connections Wiring or Mixer Insert Send Converter Output or Mixer Ins Return Converter Input Channel Split O U T P U T 2 OUT P U T 2 O U T P U T 1 OUT P U T 1 I N P U T IN P...

Страница 9: ...Otherwise all inputs and outputs are balanced electronically Output 2 cannot be fit ted with a transformer It is actively decoupled and allows for the input signal to be split into two output signals...

Страница 10: ...the operation of the ATTACK control please refer to Technology on page 19 cont The ATTACK control circuitry uses two envelope generators One follows the shape of the original curve and adapts perfect...

Страница 11: ...on and explanation of the possible applica tions of the SUSTAIN control please refer to Applications page 14 cont Output Gain The OUTPUT GAIN control allows you to reduce the output signal by up to 22...

Страница 12: ...u will find that the LINK LED of the master module will not illuminate This tells you that you have pressed the wrong LINK button since the controls of the master module control both devices in LINK m...

Страница 13: ...ndicates that an audio signal reaches the input with a level above 20dB This LED helps the operator especially in complex setups to determine immediately whether the Transient Designer actu ally recei...

Страница 14: ...lly the FX parts of too dry signals are strengthened Applied to single instruments or loops the Transient Designer allows you to create entirely new sounds and or effects The following examples are gi...

Страница 15: ...hear a lot of unusual stereo movement Enjoy an amazingly simple integration of drum sounds into a mix If the acoustic level of a snare is expanded to approximately 4dB by increasing the attack value t...

Страница 16: ...and with less ambience simply reduce SUSTAIN The Transfer Of Dynamic Structures This application requires two modules in the basic and four modules in stereo mode Feed a master module with a kick dru...

Страница 17: ...ing of the reverb is strongly reduced whereas the sustain blossoms and seems almost endless obviously that will only happen if the decay of the reverb in the actual reverb device has been set to a suf...

Страница 18: ...s Increase the ATTACK values to re gain a more natural response characteristic The sounds occupy less space in the mix and appear more identifiable even at lower volumes Post Production When dealing w...

Страница 19: ...loud signals pianissimo to fortissimo are treated the same way Both ATTACK and SUSTAIN control circuitries operate simultaneously and don t affect each other The ATTACK Control Circuitry The ATTACK co...

Страница 20: ...N Control Circuitry The SUSTAIN control circuitry also plays host to two envelope genera tors The envelope tracker Env 3 again follows the original waveform The envelope generator Env 4 maintains the...

Страница 21: ...s the control voltage of the VCA Diagram 6 displays the processed waveforms with maximum and mini mal sustain to compare against the original waveform in diagram 4 Diagram 4 Generated Envelopes Sustai...

Страница 22: ...ectronically balanced optionally transformer balanced Impedance ca 20kOhm Max Input Level 21dBu Outputs XLR connectors electronically balanced Output 1 optionally transformer balanced Output 1 Impedan...

Страница 23: ...RackPack Transient Designer 23 Block Diagram...

Страница 24: ...s from a softer and silky atmosphere without being emphasized Further advantages are aspects of improved operational safety gal vanic insulation excludes the transmission of damaging currents Electrom...

Страница 25: ...call Settings LINK ON T R A N SIENT DESIGNER 2 7 1 5 dB dB S I G O V L 2 0 1 5 1 0 6 3 0 1 2 3 5 6 SUSTAIN 2 4 1 8 1 2 6 3 0 3 6 1 2 1 8 2 4 OUTPUT GAIN ATTACK 1 5 1 3 1 0 6 3 0 3 6 1 0 1 3 1 5 dB Art...

Страница 26: ...RackPack Transient Designer Manual Transient Designer Modell 2715...

Отзывы: