![SPL Supreme dri bubble Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/spl/supreme-dri-bubble/supreme-dri-bubble_manual_1348841006.webp)
4. Fix the Main unit to Wall mounting bracket
4.1 Position the unit centrally above the wall mounting bracket so the metal bracket on the rear is positioned
over the mating part of the wall bracket moulding. Keeping the dryer firmly against the wall, slowly slide the
dryer down until there is no further travel. The dryer should then be electrically connected (fig 7).
4.2 Insert and tighten the security screw seated on the bottom surface (fig 7A).
3. Installing Power cable & Connection terminal block
WARNING: ENSURE POWER NOT CONNECTED
3.1 Pull the cable through the hole in the wall mounting bracket. Ensure the cable is long enough to route
correctly through the wall mounting bracket to the terminal block (fig. 6).
3.2 The cable must sit in the dedicated channel. If the cable come through Power cable entry from outside, It is
recommended that the cable is routed via the 3 bosses as in fig. 6B .
3.3 As shown, connect cable to terminal block.
3.4 Screw in terminal block.
3.5 Fix the wall mounting bracket to the wall. Screw to the wall using the appropriate fitting (fig 6A).
3.6 Fix the cable cover with screw on the wall mounting bracket.
Power Cable Entry
6
L
N
6mm
Power Cable Exit
(in case with power cord cable)
CAUTION:
Connect the ground wire to the terminal block marked “ ”
Do not over-tighten and crush the power cable.
6A
7
7A
5. Turn power on and test the unit for correct operation.
L
N
6
EN
Back View
6B