11
Input & output stages
Instrumentation amplifier, electronically balanced
(differential) transformerless
Jack type
TRS
XLR type
NC3
Nominal input level
+6dB
Input impedance
= 220 kOhms
Output impedance
< 600 Ohms
Max. input level
+24dBu
Reference level
variable (Drive)
Minimum load ohms
600 Ohms
Hard bypass switch
yes
Measurements
Frequency Response
30 Hz - 40 kHz
(40 kHz = -3 dB)
CCMR
-100 dBu @100 Hz
(common mode rejection)
-100 dBu @1kHz
- 80 dBu @ 10 kHz
- 70 dBu @ 20 kHz
THD & N
0,41% @1 kHz
(total harmonic distortion & noise)
K2 max. 35%
S/N CCIR 468-2
-89dBu
Power Supply
Toroidal transformer
15 VA
Fuse
315 mA
Ground lift switch
yes
Voltage selector
yes
Dimensions
Housing
Standard EIA 19"/1U
482 x 44 x 237mm
Weight
3,4 kg
Subject to change without notice.
Specifications