15

Operation

Equalizer

On

The On button inserts the Equalizer module into the signal path. Under
normal circumstances the input signal comes from the compressor. With the
Pre-comp button the Equalizer can be switched in before the Compressor/
Limiter so that the input signal is received from the De-Esser or Insert.

Pre Comp.

The Pre Comp. button reverses the sequence of Compressor/Limiter and
Equalizer: When the button is pressed the Equalizer operates in front of the
Compressor/Limiter; when not pressed the succession remains unchanged.
This function permits very flexible operation with the Channel One when it
is necessary to resolve recurring problems or to create special sounds.

The following example describes when the Equalizer (EQ) is to be switched

in front of the Compressor/Limiter.

When over-accentuation of instruments or voices is registered within

certain frequency ranges these ranges should first be reduced with the EQ.
The signal can subsequently be compressed more easily. If not done in this
sequence the compressor would react very strongly to these ranges; subse-
quent equalization would mean that the compression would be clearly
audible (the problem frequencies would then be too soft). A further sensible
application of the Pre Comp. function is the use of the compressor module
as a limiter to maintain a stable output level. If the EQ was to be used again
after limiting it could not be guaranteed that the output level would not
alter.

Air Band

The high frequency filter in the equalizer module is described as the ”Air
Band” and serves the processing of the frequency range of 2 and 20 kHz. A
coil-capacitor-filter with so called bell characteristics and a center frequency
of 17.5 kHz comes into operation here. At this frequency the maximum
possible accentuation is +10 dB, the maximum possible damping is -10 dB.
The characteristics of the Air Band filter are shown in diagram 2 on page 24.

Содержание 9945

Страница 1: ...Model 9945 Manual Channel Strip...

Страница 2: ...imitations of Liability In no event will SPL be liable for any damages including loss of data lost profits cost of cover or other special incidental consequential or indirect damages arising from the...

Страница 3: ...ng De Esser 11 Insert Insert 12 Compressor Limiter On 12 Limit Gain Reduction Noise Gate 13 Make Up Technical Information regarding the Compressor Limiter 14 Equalizer On Pre Comp Air Band 15 Mid Hi B...

Страница 4: ...s for sound processing the total bandwidth of subtle corrections to low fidelity sounds is available The versatility and completeness of the unit permits its use in additional areas over and above the...

Страница 5: ...l One The unit should be situated away from heat sources and direct sunlight Avoid installation in environments exposed to vibrations dust heat cold or moisture Keep the unit away from transformers or...

Страница 6: ...6 Connections Rear Front Wiring...

Страница 7: ...e Mic connector is used to plug in microphones of any type dynamic condenser or tube microphones etc If 48 V phantom power is required for some mics switch on the 48 V button For further information p...

Страница 8: ...o both channels of the converter The maximum input level should not exceed 12 dBu to avoid clipping of the converter 12 dBu represents the digital full scale level 0 dBfs Playback Inputs The playback...

Страница 9: ...re is to be adhered to Firstly connect the microphone to the Channel One then switch on the phantom power you can now commence work When recording has been completed firstly switch off the phantom pow...

Страница 10: ...The Clip LED will warn you of potential peaks if during recording the Clip LED illuminates the preamplifying value is to be reduced accordingly Instrument Line On Mic Off This button allows selection...

Страница 11: ...y band of about 2 octaves with compressor techniques the Auto Dynamic De Esser utilizes filters that process only the reducible S frequencies but do not interfere with the remainder of the spectrum Th...

Страница 12: ...essor EQ combination which because in this manner the Channel One can be used as 2 independent units broadens the range of uses enormously As long as units are not connected to the insert loop the sig...

Страница 13: ...in the display field is of great assistance The effect on the selected compression rate is scaled in 1 5 dB steps Depending on signal source and dynamic structure the reduction values should lie betwe...

Страница 14: ...t distortions Even the control of the release time is dependent on the input signal Fast and large level fluctuations are correspondingly processed with shorter time constants than minor fluctuations...

Страница 15: ...within certain frequency ranges these ranges should first be reduced with the EQ The signal can subsequently be compressed more easily If not done in this sequence the compressor would react very stro...

Страница 16: ...constant Q filters if a more thorough setting has been chosen this will lead to far preciser definition of the frequency range to be processed This in turn minimizes influences from adjacent ranges Th...

Страница 17: ...distinctly perceptible harmonics The distortion stage is located in front of the equa lizer so that the even newly created spectrums can be processed with the EQ The overmodulated field effect transis...

Страница 18: ...signal when activated the PPM Output display does not show any values An instance of a sensible application could possibly be when the output signal of the Channel One together with the playback sign...

Страница 19: ...ing starts whether he can hear himself and the playback adequately The best conditions for good intonation stemming from a relaxed working environment prevail Another practical use of the headphone mo...

Страница 20: ...rdriven Microphone Instrument Line Gain an excessive Make Up value in the Compressor Limiter too much boost in the EQs or too high output level Possible causes of overload can be quickly detected by s...

Страница 21: ...ly 6 dB so that the output value can exceed this limit without causing clipping The range of optimal noise performance lies between 0 and 9 dB Built around a torroidal transformer the power supply all...

Страница 22: ...rument Input Frequency Response 10 Hz 100 kHz 100kHz 3dB Common Mode Rejection 1 kHz 80 dB 10 kHz 78 dB 0dBu only Line Input THD N Amplification A weighted 5 dB 99 4 dBu 20 dB 97 2 dBu 42 dB 79 4 dBu...

Страница 23: ...23 Block Diagram Channel One Model 9945 1999 SPL electronics GmbH...

Страница 24: ...imiter The reference curve A displays the relation between input and output Curve B shows the curve characteristics of the Compressor The soft knee characteristic is clearly visible Curve C portrays t...

Страница 25: ...ous cut and boost settings of the Mid Hi filter at 3 kHz The proportional Q characteristic is distinctly visible Diagram 4 displays the curves of the Low Band filter Various cut and boost settings at...

Страница 26: ...authorized SPL warranty repair facility in the country where purchased or to the SPL factory in Germany in the original packaging or a replacement supplied by SPL with all transportation costs and ful...

Страница 27: ...27 Copy Master...

Страница 28: ...28 Manual Notes...

Отзывы: