Indicator lamp is flickering and
Check electrical connections See-
room temp. display indicates"E2".
Note
- To stop the power lamp from flickering, reset the heater by restarting the unit or by disconnecting
it from the power supply.
- If the fault cannot be identified or corrected using the above list (or remedy suggests contacting
JETFIRE service agent) stop using the machine immediately and contact JETFIRE service
agent to rectify the fault.
Turn operating switch to "OFF" and-
allow to cool(about 10 min.)
Ensure heater cord & extension cord-
are plugged in & check power supply.
Replace PCB board.
4. Check elec. connections See
Wiring Diagram.
Heater does not turn on and
the lamp is not light.
Temperature limit Control device is-
overheated.
No electrical power.
Blown fuse.
Bad electrical connection between-
Temperature limit Control and -
Dirt in Nozzle.
Water in fuel tank.
Flame is unstable and/or
Soot occurs from Hot air outlet.
Clean Nozzle.
Flush fuel tank with clean kerosene.
control PCB.
Fan does not turn when heater
is plugged in and Operating switch
is in the "ON "position.
(Indicator lamp is on)
Turn thermostat control knob to a
Thermostat setting is too low.
higher setting.
Fuel leak at Fuel pipe or Fuel lines.
Tighten Fuel pipe or Replace-
Fuel lines.
Replace Electronic Pump.
Defective Electronic Pump
room temp. display indicates"E3"
Thermistor Failure.
Replace Display PCB in the Back -
Cover See Wiring Diagram
Bad electrical connection between-
Wiring Diagram.
Thermistor and Control PCB.
Thermistor Failure.
Replace Thermistor.