background image

 

 19 

 

 

 

 

1.  To ensure machine safety, use only original 

spare parts from the manufacturer or approved 
by the manufacturer. 

2.  Carry out all regular maintenance and 

inspections as listed in this manual using 
original Spitwater parts where required. 

3.  Always make sure before carrying out any 

maintenance that the unit is turned off, 
disconnected from the battery (at least positive 
or negative terminal of the battery), allowed to 
cool down and any trapped high pressure in its 
system has been released. 

4.  Never carry out any maintenance work not 

specifically outlined in this booklet and never 
make any technical modifications to this unit. 

5.  This unit is fitted with safety devices which are 

set and sealed at the factory. It is very 
important these devices receive their routine 
maintenance to assure your safety as well as 
necessary protection of the unit. 

6.  There are a number of important 

components that have been set and sealed 
at the factory. Never under any 
circumstances tamper with, modify or 
adjust these settings. 

7.  Make sure this unit is regularly serviced by an 

authorized Spitwater service agent according 
to the servicing requirement outlined in this 
booklet. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

To maintain this unit in peak working condition 
during its operating life it is necessary to carry out 
regular maintenance operations and replace worn 
or broken parts immediately upon their failure. 
Spitwater recommends that all maintenance is 
carried out by an authorized Spitwater service 
agent using original Spitwater spare parts. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failure to follow the maintenance 
guidelines in this manual releases the 
manufacturer from any responsibility 
in reference to injuries and damages 
to both persons and goods. 

 

 

SERVICE / CARE RECOMMENDATIONS AND DIY TROUBLESHOOTING GUIDE

 

SAFETY PRECAUTIONS 

SERVICE INSTRUCTIONS 

 

Always dispose of oil, 
batteries, chemicals 
and unused 
equipment safely and 
according to the 
requirements of local 
authorities 

 

 

 

 

 

 

 

  

Содержание HP201SAE

Страница 1: ...and this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufacturer...

Страница 2: ...ccordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the ma...

Страница 3: ...A N A N A V Ah 20HR 26 26 Ah CCA 280 280 A PUMP MODEL WS251 WS202 N A N A N A OIL TYPE 15W 40 15W 40 OIL CAPACITY 1 1 L OTHER DETERGENT BOTTLE CAPACITY 5 5 N A L VALUES DETERMINED AS PER AS NZS 60335...

Страница 4: ...ntial injury if not cautious Their meaning is listed next to them for your attention CAUTION Hot surface Do not touch DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS WARNING This...

Страница 5: ...Do not alter or remove safety labels WATER INLET CONNECTOR PRESSURE GAUGE TRIGGER GUN SERIAL LABEL CHEMICAL FLOW ADJUSTMENT ENGINE SWITCH HIGH PRESSURE HOSE PRESSURE HIGH LOW SCWA60 A ONLY PETROL TAN...

Страница 6: ...ly authorized to do so DO NOT operate the unit without appropriate personal protective equipment PPE 2 FIRE PREVENTION Store flammable fluids in approved containers and cabinets away from sparks and h...

Страница 7: ...of hot components e g muffler muffler cover and engine body during operation and after the engine has been shut off 6 CHEMICAL HAZARD In the event of accidental contact with cleaning detergent or oil...

Страница 8: ...user is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries...

Страница 9: ...er components When finishing work switch OFF the unit and release any trapped pressure in the hose and engage the gun trigger lock Never leave the unit unattended while it is running Never lock the sp...

Страница 10: ...in order to prevent it from sliding or falling 4 If transporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or be...

Страница 11: ...erate on an uneven surface or on loose gravel 5 The engine and exhaust becomes very hot during operation Keep the unit at least 1metre 3 feet away from buildings or other equipment during operation AS...

Страница 12: ...s do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 10 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quic...

Страница 13: ...release adaptor to the high pressure hose fitting Do not over tighten 11 ASSEMBLY OF HIGH PRESSURE HOSE WITH THE UNIT Connect the quick release high pressure hose to the outlet connector of the unit H...

Страница 14: ...er tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is considered to be non potable non drinkable For suction su...

Страница 15: ...starter for more than 5 seconds at a time will overheat the starter motor and can damage it When the engine starts release the engine switch allowing it to return to the ON position RECOIL START 1 Tur...

Страница 16: ...matches the value on the data plate and in the technical data Also check that when the trigger is released the pressure shown on the gauge returns to zero 4 To adjust spray angle turn the nozzle head...

Страница 17: ...y circumstance acid or corrosive products contact an authorized service agent or the manufacturer if in doubt 1 If detergent is required it CAN BE USED IN LOW PRESSURE ONLY 2 Open the chemical injecto...

Страница 18: ...the unit by pulling the trigger of the spray gun then engage the spray gun trigger lock Failure to follow this instruction will leave the unit in a potentially unsafe manner 4 If the unit is to be le...

Страница 19: ...There are a number of important components that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly se...

Страница 20: ...oil leakage and contamination Check for any service due based on USAGE VS SERVICE FREQUENCY Table A CHECKS DURING UNIT RUN Check for proper functioning of pressure gauge Check for water leaks at high...

Страница 21: ...hecks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal conditions eg heavy use dirty water extreme temperatures or condition...

Страница 22: ...the pump Make sure the level is between min max level notches on the dipstick or is level with the indicator on the sight glass Ensure the unit is on a flat surface Remove the oil level dipstick and...

Страница 23: ...vice agent Water leaking from pump Contact Spitwater service agent Oil leaking from pump Contact Spitwater service agent Engine does not start operate correctly Refer to engine instruction book Contac...

Отзывы: