Customer Service 1-888-707-1880
Dyaco Canada Inc. 2016
Email: [email protected]
38
CALIBRATION PROCEDURE
1. Remove the safety key
2. Press and hold down the
Start
and
Speed +
buttons and replace the safety key. Continue to hold
the
Start
and
Speed
key until the window displays “Factory settings”, then press the
Enter
key.
3. You will now be able to set the display to show Metric or English settings (Miles vs. Kilometers).
To do this, press the
up or down
key to show which you want, then press
Enter
. (The maximum
speed is displayed in the speed window, and the maximum elevation is displayed in the incline
window.)
4. Grade return – On (This allows the incline to return to zero when
Stop
is pressed.)
5. Press
Start
to begin calibration. The process is automatic; the speed will start up without warning,
so do not stand on the belt.
ADJUSTING THE SPEED SENSOR
If the calibration does not pass you may need to check the speed sensor alignment.
1. Remove the motor cover hood by loosening the 4 screws that hold it in place (you do not need to
remove them completely).
2. The speed sensor is located on the left side of the frame, right next to the front roller pulley (the
pulley will have a belt around it that also goes to the motor). The speed sensor is small and black
with a wire connected to it.
3. Make sure the sensor is as close as possible to the pulley without touching it. You will see a
magnet on the face of the pulley; make sure the sensor is aligned with the magnet. There is a
screw that holds the sensor in place that needs to be loosened to adjust the sensor.
Re-tighten the screw when finished.
ENGINEERING MODE MENU
The console has built in maintenance/diagnostic software. The software will allow you to change the
console settings from English to Metric and turn off the beeping of the speaker when a key is pressed
for example. To enter the Engineering Mode Menu, press and hold down the
Start
,
Stop
and
Enter
keys. Keep holding the keys down for about 5 seconds and the Message Center will display
Engineering Mode Menu. Press the
Enter
key to access the menu below:
1.
Key Test
(Will allow you to test all the keys to make sure they are functioning)
2.
Display Test
(Tests all the display functions)
3.
Functions
(Press
Enter
to access settings and
Speed Up or Down
keys
to scroll)
I.
Display Mode
(Turn on to have the console power down automatically after 30 minutes of inactivity)
II.
Pause Mode
(Turn on allow 5 minutes of pause, turn off to have the console pause indefinitely)
III.
Maintenance
(Allows you to reset the lube message time)
IV.
Units
(Sets the display to readout in English or Metric display measurements)
V.
Beep
(Turns off the speaker so no beeping sound is heard)
4.
Security
(Allows the keypad to be locked to prevent unauthorized use)
5.
Exit