Initial Installation
Management Port Configuration
26
|
Spirent Landslide Test System Installation Guide
•
Specify the address for the IPv6 gateway in your network, then press
Enter
to
continue.
<
port
> <
TAS / TS / TAS+TS
>
IPv6 Gateway []:
•
Specify the MTU of the server, then press
Enter
to continue.
<
port
> <
TAS / TS / TAS+TS
>
MTU size (recommend: 1500; Range:
1000->1500) [1500]:
10
The user will be prompted to specify the host name of the server.
•
Specify the host name of the server, then press
Enter
to continue. Do not use any
blank spaces in the Host Name.
<
TAS / TS / TAS+TS
>
Host Name [osU1404]:
Note:
Confirm the networking properties assigned to the management port. Failure to
use the proper values may prevent communication with the platform.
11
TS Only
- Enter the IPv6 address for the Landslide Manager.
TAS IP Address []:
Note:
This step only applies to a Landslide Test Server that will be communicating
with a Landslide Manager. If the Landslide Manager’s IP address is changed after
completing the Landslide installations, the Landslide Test Server configurations must
be modified to restore communication between the platforms.
12
The VPN Service is currently only supported for an IPv4 management IP Address.
Press
Enter
to accept the default value of
disable
to skip configuration and continue.
Modify VPN Service status (enable/disable) [disable]:
13
A time server is defined for every platform. Landslide supports both NTP and PTP.
Specify
ntp
or
ptp
and press
Enter
to proceed with Time Sync Protocol
configuration.
<
TAS / TS / TAS+TS
>
Time Sync Protocol (ntp/ptp) [ntp]:
If
ntp
is selected, configure the NTP Server IP, specify the IPv4 or IPv6 address of the
NTP server to be used. The TAS management IP address can be used as a common
timing source for all test servers as well as other devices.
<
TAS / TS / TAS+TS
>
NTP Server IP []:
If
ptp
is selected, configure the PTP Transport Mode, specify either
ipv4
or
ethernet
and then press
Enter
to select the PTP transport mode.
PTP Transport Mode (ipv4/ethernet) [ipv4]:
If
ipv4
is selected, configure the PTP IP Mode. Specify
multicast
,
unicast
or
hybrid
for the PTP IP Mode, then press
Enter
to continue.
PTP Transport Mode (multicast/unicast/hybrid) [multi
-
cast]:
If
unicast
is selected, configure the PTP Master Clock IP, specify a valid IPv4
address for the PTP Master Clock.
PTP Master Clock IP [10.1.1.1]:
Содержание Landslide C100
Страница 1: ...P N 71 008573 REV A Installation Guide Spirent Landslide Test System October 2018 ...
Страница 12: ...12 Spirent Landslide Test System Installation Guide ...
Страница 16: ...16 Spirent Landslide Test System Installation Guide ...
Страница 28: ...Initial Installation Management Port Configuration 28 Spirent Landslide Test System Installation Guide ...
Страница 44: ......
Страница 48: ...48 Spirent Landslide Test System Installation Guide ...