Initial Installation
Management Port Configuration
22
|
Spirent Landslide Test System Installation Guide
7
A warning will be displayed, and the user will be asked if they wish to continue. Type
yes
and press
Enter
to continue.
Note: Do not terminate this utility, otherwise it can lead to
system instability! Do you wish to Continue (yes/no) [no]:
8
The user will be prompted to identify the port to be used as the management port. The
user must select the recommended and default port number as the management port
(eth0) for IPv4 management. Press
Enter
to accept the default value and continue.
NOTE - Preferred management port is eth0
Designate management port (eth0/eth0v6 --eth17
eth17v6)[eth0]:
9
The user will be prompted to configure the IP Address mode. Specify
static
or
dynamic
, then press
Enter
to continue.
Configure TS IP Address mode (static/dynamic) [static]:
If
static
is selected, answer the resulting configuration prompts.
•
Specify a unique IPv4 address for the management port, then press
Enter
to
continue.
<
port
> <
TAS / TS / TAS+TS
>
IP Address []:
•
Specify the IPv4 network mask, then press
Enter
to continue.
<
port
> <
TAS / TS / TAS+TS
>
Network Mask []:
•
Accept the default configuration to enable automatic speed and duplex
negotiation by pressing
Enter
to continue.
<
port
> <
TAS / TS / TAS+TS
>
Auto Negotiate? (yes/no) [yes]:
•
Specify the address for the IPv4 gateway in your network, then press
Enter
to
continue.
<
port
> <
TAS / TS / TAS+TS
>
IP Gateway []:
10
The user will be prompted to configure the MTU size.
•
Specify the MTU of the server, then press
Enter
to continue.
<
port
> <
TAS / TS / TAS+TS
>
MTU size (recommend: 1500; Range:
1000->1500) [1500]:
11
The user will be prompted to specify the host name of the server.
•
Specify the host name of the server, then press
Enter
to continue. Do not use any
blank spaces in the Host Name.
<
TAS / TS / TAS+TS
>
Host Name [osU1404]:
Note:
Confirm the networking properties assigned to the management port. Failure to use
the proper values may prevent communication with the platform.
12
TS Only
- If the system being provisioned is a Landslide Test Server, the user will be
prompted to configure the TAS IP Address mode for the TAS that the TS will connect
to. Otherwise, the following prompt is skipped. Specify
static
or
dynamic
, then press
Enter
to continue.
Содержание Landslide C100
Страница 1: ...P N 71 008573 REV A Installation Guide Spirent Landslide Test System October 2018 ...
Страница 12: ...12 Spirent Landslide Test System Installation Guide ...
Страница 16: ...16 Spirent Landslide Test System Installation Guide ...
Страница 28: ...Initial Installation Management Port Configuration 28 Spirent Landslide Test System Installation Guide ...
Страница 44: ......