IM-P403-89
EMM Issue 8
64
10.8 Default settings
10.8.1 MODE MENU
Allows the valve to be manually opened or closed
Ranges
OPEN or CLOSE
Default
CLOSE
10.8.2 DATA MENU
TEMP (temperature units)
Ranges
°C or °F
Default
°C
UNITS (TDS or conductivity units)
Ranges
µS / cm or ppm
Default
µS / cm
PH TERM
Ranges
0.50 - 1.00
Default
0.7
Resolution (steps)
0.01
Assuming µS / cm to ppm conversion = 0.7
10.8.3 INPUT MENU
T COMP (Temperature compensation)
Ranges
100 - 250
°C or 212 - 482
°F
Default
184
°C (10 bar g) or 363
°F
Resolution (steps)
1
°
Units
°C or °F
TDS - SENSOR (Probe selection)
Ranges
CP10, CP30, CP32
Default
CP10