- 18 -
The ON/OFF switches on the power supply and to the spray head must be OFF
before starting cleaning opération.
Wait for 10 seconds before entering the drum
All metallic parts located within and around the spray head must be correctly
connected to the ground. The floor must be electrically conductive and grounded.
Only apply a moderate amount of cleaning solution onto a clean soft cloth or bristle
brush to clean the spray head and hoses.
Synthetic resins used in the fabrication of the electrostatic spray head can react
with certain cleaning agents. Check with SAS .
CAUTION : avoid using the most toxic cleaning agents. Do not use chlorinates.
Dry the spray head carefully and thoroughly with air.
PROCEDURE
1. Turn the power supply ON/OFF switch to OFF position
2. Hose down the complete system in situ. There is no need to remove the system for
cleaning
3. Wash thoroughly and dry completely with compressed air before commencing
production.
(THIS IS VERY IMPORTANT. IF THE UNIT IS NOT DRY IT CAN LEAD TO
BLOCKAGES)
Warning : never switch ON the Electric power supply unit during the washing and
cleaning operation.
Before switching ON the electrostatic effect :
- Install the spray nozzle onto the spray head.
- Connect the flexible powder tube to the spray nozzel
- Connect the 8mm air line to the injector
- Check that the spray head, cone, injector and powder delivery tube to the spray head are
completely dry.