- 17 -
START UP
ELECTROSTATIC CIRCUIT
1 - Connect the SAS control to its power source
2 - Supply the SAS control with clean dry compressed air (P = 4 bar / 58 psi)
3 - Turn the power-supply ON/OFF switch to the ON position (Item 3)
4 - Turn the voltage on/off switch on (Item 5)
Î
The power supply emits a constant voltage at any given setting from 3,5 to 13 Vdc.
This regulated voltage is transformed into high voltage within the generator barrel
before being delivered to the spray head.
QUALITY ADJUSTMENT
Adjust the spraying parameters ON THE FRONT OF THE CONTROL:
-
Material flow rate (Pressure regulator Item 1 Page 9) Adjust by turning clock
wise for more air anti-clockwise for less air. Push in to lock, pull out to unlock
(Item 2 Page 9)
-
Electrostatic effect : High voltage is on when the yellow light is glowing.
-
Yellow light is dim : The spray heads are positioned too close to the product.
Need to be adjusted further away.
All hoses and the generating head must remain dry.
The electrostatic efficiency decreases quickly when spray head and hoses are dirty or
damp, this can also lead to blockages.
CLEANING METHOD