background image

23

ELBOW VALVES

SP164 SHORT STROKE ELBOW VALVE

SP165 LONG STROKE ELBOW VALVE

VALVE DIMENSIONS

SHIPPING 

#S

SIZE

A

B

2”

15 3/4”

3 1/2”

19 #

2.5”

16 1/2”

4 1/4”

19 #

3”

17 1/4”

5”

20 #

VALUES ARE SHOWN WITH #10 ACT.

VALVE DIMENSIONS

SHIPPING 

#S

SIZE

A

B

2”

20 1/4”

3 1/2”

22 #

2.5”

21”

4 1/4”

23 #

3”

21 3/4”

5”

25 #

VALUES ARE SHOWN WITH #10 ACT.

Содержание VALVES SP160 Series

Страница 1: ...VALVES INSTALLATION OPERATION MAINTENANCE ...

Страница 2: ...Flow Diversion Valves 24 Modulating Valves 25 32 Parts Lists 33 52 Disassembly Instructions SP 160 Shut Off Valve 53 59 Microswitch Assembly Instructions 60 67 Valve Body Plug and Stem Identification 68 Modulating Actuator Assembly Instructions 69 74 Moore Positioner Installation and Service Instructions 75 82 Moore Positioner Removal 83 Spring Piston and Actuator Stem Removal 84 Fractional Valves...

Страница 3: ... the SP160 valve SPI valves are designed for minimal routine maintenance but care and attention should be given to the instructions provided in this manual Do not remove any labeling on any SPI product Immediately replace any label that is missing If at any point you have questions or concerns regarding your SPI valves please call 1 800 558 9446 or 262 859 2826 ...

Страница 4: ...surrounding persons at risk of personal injury and or result in equipment damage Do not remove any labeling on any SPI product Immediately replace any label that is missing DISCLAIMER OF LIABILITY SPI does not assume responsibility and expressly disclaims liability for loss damage or expenses that arise in any way from the installation operation use or maintenance performed in accordance with this...

Страница 5: ... PTFE all FDA approved O rings EPDM Viton all FDA approved Bonnet 304 stainless steel Actuator parts 304 stainless steel SEAL TYPES Non replaceable over molded EPDM Non replaceable over molded Viton Replaceable PTFE SURFACE FINISH 32Ra or less on product contact surfaces APPROVALS 3 A per 53 06 Materials FDA approved ...

Страница 6: ...TFE STROKE OPTIONS SP160 SHORT STROKE SP161 LONG STROKE VALVE SIZE 0 5 0 75 1 1 5 2 2 5 3 4 SP161 ONLY BODY STYLE SHUT OFF 7 TEE BODY 9 CROSS BODY DIVERT 77 UPPER TEE LOWER TEE 79 UPPER TEE LOWER CROSS 97 UPPER CROSS LOWER TEE 99 UPPER CROSS LOWER CROSS INDICATION OPTIONS BLANK NO SWITCH MS MICRO SWITCH PRX PROX SWITCH Switches not available on 4 inch valves or light duty spring actuators ACTUATOR...

Страница 7: ... SP20 Normally Closed Air to Open Spring to Close SP30 Air to Air Air to Open Air to Close SP10 70 Light Duty Spring Normally Open Air to Close Spring to Open 3 15 PSI Air Pressure SP20 70 Light Duty Spring Normally Closed Air to Open Spring to Close 3 15 PSI Air Pressure ...

Страница 8: ...P20 ACTUATOR 1 2 195 PSI 3 4 50 PSI 1 AND 1 1 2 190 PSI 2 100 PSI 2 1 2 60 PSI 3 45 PSI 1 1 2 2 2 1 2 3 60 70 80 90 100 110 120 130 10 20 30 40 50 60 70 80 90 100 Air Pressure PSI Line Pressure PSI SP10 ACTUATOR LINE PRESSURE CURVE The chart below illustrates the air supply which must be available to a normally open air to close valve in order to fully shut off against the corresponding fluid pres...

Страница 9: ...ALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE 1 14 7 8 17 9 16 2 1 2 2 27 32 16 1 2 18 1 5 15 5 8 18 5 16 2 3 4 2 15 16 16 1 2 18 2 15 5 8 19 13 16 3 1 2 3 7 16 16 1 2 19 1 2 2 5 17 20 11 16 3 1 2 3 15 16 18 20 1 2 3 17 11 16 22 1 4 3 3 4 4 9 16 20 22 1 2 A C B B A B B A B B A C B B A C B B A C B B VALVES ARE SHOWN WITH 20 ACT ALL VALVES ARE STANDARD WITH SANITARY CLAMP END CONNECTIONS PLEASE CONT...

Страница 10: ...FE REPLACEABLE SEAT SP160 9 X ACT SP160 77 X ACT SP160 7MH X SP160 9 X H SP160 7S X H A B B A B B A B B X VALVE SIZE A B B A B B A C B B SP45V X VALVE DIMENSIONS SIZE A B C SHUT OFF VALVE DIVERT VALVE HAND OPERATED CHECK VALVE SHUT OFF VALVE DIVERT VALVE 0 5 9 3 16 11 1 4 7 1 2 4 2 2 3 16 ...

Страница 11: ... Water Flow Rate GPM SP160 7 Tee Body Valve SP160 7 Tee Body Valve SP160 77 Divert Valve SP160 77 Divert Valve 1 2 3 4 0 10 20 30 40 50 60 0 10 20 30 40 50 Loss Feet of Water Flow Rate GPM SP160 77 Divert Valve 1 2 3 4 0 10 20 30 40 50 60 0 10 20 30 40 50 Loss Feet of Water Flow Rate GPM SP160 7 Tee Body Valve ...

Страница 12: ...Flow Rate GPM Loss Feet of Water 2 1 2 1 40 50 60 70 Water SP160 77 Divert Valve 1 1 2 2 3 0 10 20 30 40 0 25 50 100 150 200 250 300 350 400 Loss Feet of Flow Rate GPM SP160 77 Divert Valve 1 1 2 2 2 1 2 3 1 0 10 20 30 40 50 60 70 0 25 50 100 150 200 250 300 350 400 Flow Rate GPM Loss Feet of Water SP160 7 Tee Body Valve SP160 77 Divert Valve SP160 77 Divert Valve ...

Страница 13: ...SP120 Normally Closed Air to Open Spring to Close SP130 Air to Air Air to Open Air to Close SP110 70 Light Duty Spring Normally Open Air to Close Spring to Open 3 15 PSI Air Pressure SP120 70 Light Duty Spring Normally Closed Air to Open Spring to Close 3 15 PSI Air Pressure ...

Страница 14: ...pring in a normally closed air to open valve will hold VALVE SIZE SP120 ACTUATOR 2 50 PSI 2 1 2 30 PSI 3 20 PSI 4 Contact Factory SP110 ACTUATOR LINE PRESSURE CURVE The chart below illustrates the air supply which must be available to a normally open air to close valve in order to fully shut off against the corresponding fluid pressure ...

Страница 15: ... OFF VALVE DIVERT VALVE 2 21 3 4 25 3 4 3 1 2 3 7 16 16 1 2 19 1 2 2 5 22 1 2 27 1 4 3 1 2 3 15 16 18 20 1 2 3 23 7 8 29 3 3 4 4 9 16 20 22 1 2 VALVES ARE SHOWN WITH 120 ACT SP161 9 X ACT SP161 79 X ACT SP161 77 X ACT SP161 7 X ACT SP161 97 X ACT SP161 99 X ACT X VALVE SIZE ALL VALVES ARE STANDARD WITH SANITARY CLAMP END CONNECTIONS PLEASE CONTACT FACTORY FOR OTHER OPTIONS ...

Страница 16: ...4 ACT VALVES ARE SHOWN WITH 120 ACT ALL VALVES ARE STANDARD WITH SANITARY CLAMP END CONNECTIONS PLEASE CONTACT FACTORY FOR OTHER OPTIONS VALVE DIMENSIONS SHIPPING S SIZE A B C D SHUT OFF VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE 4 19 1 8 25 1 8 3 3 8 4 1 2 6 1 8 29 35 1 2 ...

Страница 17: ...ody Valve 2 2 5 3 0 5 10 15 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Loss Feet of Wa Flow Rate GPM 25 SP161 77 Divert Valve 2 2 5 20 3 4 15 ater 10 Feet of Wa 5 Loss 0 0 100 200 300 400 500 600 700 800 900 1000 45 SP161 77 Divert Valve 2 2 5 3 35 40 3 25 30 Head 4 20 25 Loss Feet of H 10 15 0 5 0 100 200 300 400 500 600 700 800 900 1000 ...

Страница 18: ...32 2 1 2 3 1 2 1 5 7 3 8 10 2 3 4 2 27 32 2 1 2 3 1 2 2 8 3 8 11 3 1 2 3 7 16 3 1 2 4 1 2 2 5 8 3 4 12 3 1 2 3 15 16 4 1 2 5 1 2 3 9 1 16 14 3 3 4 4 9 16 7 8 SP161 LONG STROKE VALVE DIMENSIONS SHIPPING S SIZE A B C SHUT OFF VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE 2 9 7 8 13 3 16 3 1 2 3 7 16 8 10 2 5 10 1 2 14 1 4 3 1 2 3 15 16 9 1 2 12 3 11 3 4 15 7 8 3 3 4 4 9 ...

Страница 19: ...Included but Optional Stainless Products micro proximity switch offerings provide a solution for those needing open and closed feedback on the SP160 family of shutoff valves A simple dual microswitch solution provides two roller style microswitches brackets hardware and a cable grip A contactless dual proximity switch solution provides two proximity switches that are pre wired It also comes with a...

Страница 20: ... SHUT OFF VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE 1 21 1 8 23 13 16 2 1 2 2 27 32 22 1 2 24 1 5 21 3 8 24 1 16 2 3 4 2 27 32 22 1 2 24 2 27 1 2 25 9 16 3 1 2 3 7 16 22 1 2 25 1 2 2 5 28 1 4 26 7 16 3 1 2 3 15 16 24 26 1 2 3 29 5 8 28 3 3 4 4 9 16 26 28 1 2 SP160MS PRX 7 BODY SP160MS PRX 9 BODY SP160MS PRX 77 BODY ...

Страница 21: ... SIZE A B C SHUT OFF VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE SHUT OFF VALVE DIVERT VALVE 2 31 5 16 33 5 8 3 1 2 3 7 16 26 1 2 29 2 5 32 7 16 34 3 8 3 1 2 3 15 16 26 1 2 29 3 33 15 16 35 3 4 3 3 4 4 9 16 30 1 2 34 1 2 SP161MS PRX 7 BODY SP161MS PRX 9 BODY SP161MS PRX 77 BODY ...

Страница 22: ... 18 22 3 16 9 16 22 11 16 2 5 8 4 1 2 20 25 4 N A 19 3 3 16 4 3 4 N A 28 VALVE DIMENSIONS SHIPPING S SIZE A B C SHORT STROKE VALVE LONG STROKE VALVE SHORT STROKE VALVE LONG STROKE VALVE 2 14 31 32 21 1 8 1 27 32 4 1 8 16 5 22 2 5 15 13 16 21 13 16 2 5 16 4 1 8 18 22 3 16 9 16 22 11 16 2 5 8 4 1 2 20 25 4 N A 19 3 3 16 4 3 4 N A 28 VALVE DIMENSIONS SHIPPING S SIZE A B C SHORT STROKE VALVE LONG STRO...

Страница 23: ...LONG STROKE ELBOW VALVE VALVE DIMENSIONS SHIPPING S SIZE A B 2 15 3 4 3 1 2 19 2 5 16 1 2 4 1 4 19 3 17 1 4 5 20 VALUES ARE SHOWN WITH 10 ACT VALVE DIMENSIONS SHIPPING S SIZE A B 2 20 1 4 3 1 2 22 2 5 21 4 1 4 23 3 21 3 4 5 25 VALUES ARE SHOWN WITH 10 ACT ...

Страница 24: ...ES LONG STROKE VALVE DIMENSIONS SIZE A B B C D E SHORT STROKE LONG STROKE 1 5 23 1 2 n a 2 3 4 2 27 32 3 6 2 25 27 1 2 3 1 2 3 7 16 3 3 4 7 1 2 2 5 25 7 8 28 1 4 3 1 2 3 15 16 3 3 4 7 1 2 3 27 7 16 29 5 8 3 3 4 4 9 16 4 8 DIVERT FLOW LEAK DETECTOR FLOW FULL FORWARD FLOW ...

Страница 25: ...ols needed for valve maintenance FEATURES AND OPTIONS SP160 SERIES MODULATING VALVES ORDERING INFORMATION SP160 7MT 2 20VPR BODY STYLE 7 TEE BODY 9 CROSS BODY 77 UPPER TEE LOWER TEE 3 1 2 PLUG STYLE M MULTI TAPER MT STRAIGHT TAPER Add H if hand operated Micro flow must be MH SIZE 1 1 5 2 2 5 3 Micro flow only available in 1 inch 5 ACTUATOR STYLE BLANK HAND OPERATED 10VPD NORMALLY OPEN 20VPR NORMAL...

Страница 26: ...RATED SHUT OFF VALVE SP20VPR SP10VPD HAND OPERATED 1 23 7 8 22 1 8 13 1 2 2 1 2 16 11 1 5 23 7 8 22 1 8 13 1 2 2 3 4 16 13 2 23 7 8 22 1 8 14 1 2 3 1 2 19 13 2 5 25 1 4 23 1 2 14 7 8 3 1 2 19 15 3 25 15 16 24 3 16 15 9 16 3 3 4 21 17 PLEASE CONTACT THE FACTORY FOR INFORMATION ON MODULATING DIVERT VALVES AND OTHER BODY CONFIGURATIONS X VALVE SIZE MODULATING VALVES ...

Страница 27: ...40 50 60 70 80 90 100 Cv Factor Valve Stroke CV VS STROKE VALVE SIZE OPERATING RANGE 10 20 30 40 50 60 70 80 90 100 1 0 0 25 0 75 1 00 1 25 1 875 3 00 4 00 5 00 6 50 12 00 1 5 0 50 1 00 2 00 3 00 4 00 6 50 6 80 8 30 9 30 14 30 2 0 1 90 3 20 7 30 11 90 14 60 16 90 20 00 24 20 29 20 33 70 2 5 2 00 3 90 8 70 14 80 20 40 26 00 31 00 37 00 47 00 53 50 3 0 4 90 10 00 18 50 24 00 31 00 39 60 56 00 72 00 ...

Страница 28: ...roke DATA IS BASED ON WATER AT 70 F CV VS STROKE VALVE SIZE OPERATING RANGE 10 20 30 40 50 60 70 80 90 100 1 0 3 00 5 00 6 60 8 10 9 60 10 80 12 00 13 20 14 30 15 40 1 5 6 60 11 00 15 50 19 40 23 00 26 50 30 00 33 20 36 80 40 00 2 0 14 00 23 80 32 50 40 00 47 80 54 70 61 00 67 00 73 50 79 00 2 5 21 60 36 00 49 00 58 80 70 00 80 00 89 50 98 00 109 00 118 00 3 0 23 20 40 70 55 50 69 00 82 00 96 00 1...

Страница 29: ...10VPD ALL MICRO FLOW VALVES HAVE 1 SP CLAMP END CONNECTIONS AVAILABLE PLUG SIZES SP160 7MH 1 X MODULATING VALVES VALVE DIMENSIONS SHIPPING S SIZE A B SP20VPR SP10VPD HAND OPERATED SHUT OFF VALVE SP20VPR SP10VPD HAND OPERATED 1 23 7 8 22 1 8 13 1 2 2 1 2 17 11 X VALVE SIZE ...

Страница 30: ... O RING SEAT OPTIONS DATA IS BASED ON WATER AT 70 F CV VS STROKE VALVE SIZE OPERATING RANGE 10 20 30 40 50 60 70 80 90 100 0 750 0 67 0 95 1 43 2 08 2 86 3 74 4 71 5 75 6 84 7 98 0 625 0 63 0 68 0 91 1 31 1 87 2 56 3 37 4 29 5 32 6 43 0 500 0 35 0 46 0 66 0 92 1 25 1 63 2 07 2 55 3 08 3 66 0 375 0 29 0 29 0 37 0 49 0 63 0 79 0 98 1 19 1 42 1 67 0 250 0 16 0 19 0 26 0 34 0 45 0 58 0 73 0 89 1 07 1 ...

Страница 31: ...ducts with a specific gravity equal to 1 0 Cv GPM p SG Formula for water and other products with a specific gravity other than water GPM Product flow rate SG Specific gravity of gravity p Pressure Drop across valve in PSI Once your Cv factor has been calculated locate your Cv factor on the charts from pages 2 3 or 5 Use the closest number to your figure If you find that your Cv factor is listed on...

Страница 32: ...t sparingly on male threads only A non hardening sealant is strongly recommended Connect the positioner to only clean dry oil free instrument air Failure to do so will increase the possibility of a malfunction Caution Synthetic compressor lubricants in the air stream at the instrument may cause the positioner to fail The requirements for quality instrument air can be found in the Instrument Societ...

Страница 33: ...ing methods can be used when air actuated valves are installed Check with local suppliers for the ideal chemicals to be used based on your requirements for effective cleaning Valves should be cycled during each step of the CIP process failure to do this can result in premature failure of valve seats and O rings Using incorrect concentrations of CIP cleaning agents excessive temperatures and exposu...

Страница 34: ...uide 5C SP10 5C I D Guide 5D SP10 5D Retaining Flange 5E SP10 5E Brass Bushing 5F SP10 5R Retaining Ring 6 SP10 6 Upper Stem O Ring 7 SP10 7 Lower Stem O Ring 8 SP10 8 Piston O Ring 9 SP10 9 Foot O Ring 10 SP13HC 4 Actuator Clamp 11 SP20 2D Actuator Stem 12 SP10 12 Stem Nut 13 SP10 14 Poly Tube Connector 14 SP10 15BV Breather Vent Plug INCLUDED IN SP20 SK ACTUATOR SERVICE KIT SP20 NORMALLY CLOSED ...

Страница 35: ...1 Cylinder Assembly 2 SP10 2 Piston 3 SP10 2D Actuator Stem 4 SP10 4 Actuator Foot 5 SP10 6 Upper Stem O Ring 6 SP10 7 Lower Stem O Ring 7 SP10 8 Piston O Ring 8 SP10 9 Foot O Ring 9 SP13HC 4 Actuator Clamp 10 SP10 12 Stem Nut 11 SP10 14 NBP Air Coupling x2 INCLUDED IN SP20 SK ACTUATOR SERVICE KIT INCLUDED IN SP20 RBK SIZE VALVE SERVICE KIT ...

Страница 36: ... 5 Spring and Cage Assembly 5A SP110 5A Spring 5B SP110 5B O D Guide 5C SP110 5C I D Guide 5D SP110 5D Retaining Flange 5E SP110 5E Brass Bushing 5F SP110 5R Retaining Ring 6 SP10 6 Upper Stem O Ring 7 SP10 7 Lower Stem O Ring 8 SP10 8 Piston O Ring 9 SP10 9 Foot O Ring 10 SP13HC 4 Actuator Clamp 11 SP120 2D Actuator Stem 12 SP10 12 Stem Nut 13 SP10 14 Poly Tube Connector 14 SP10 15BV Breather Ven...

Страница 37: ...embly 2 SP110 2 Piston 3 SP110 2D Actuator Stem 4 SP110 4 Actuator Foot 5 SP10 6 Upper Stem O Ring 6 SP10 7 Lower Stem O Ring 7 SP10 8 Piston O Ring 8 SP10 9 Foot O Ring 9 SP13HC 4 Actuator Clamp 10 SP10 12 Stem Nut 11 SP10 14 NBP Air Coupling x2 INCLUDED IN SP120 SK ACTUATOR SERVICE KIT INCLUDED IN SP120 RBK SIZE VALVE SERVICE KIT ...

Страница 38: ... 15BV SP10MS 15BV 1 8 I P Adapter Plug 13 SP10MS 1 Cylinder 14 SP10MS 14 SP10 14 1 4 Poly Tube Connector 15 SP10 9 Cover O Ring 16 SP10 7 Base Plate O Ring 17 SP10MS 40B Indicator Stem O Ring 18 SP10MS 1B Base Plate 19 SP10MS 3C Micro Switch Screw x2 20 SP10MS 3K Micro Switch Washer x2 21 SP10MS 3L MS Bracket Screw x2 22 SP10MS 3B SP20 DPS Micro Switch x2 Dual Prox Switch x2 23 SP10MS 3A MS Mounti...

Страница 39: ... 4 Poly Tube Connector x2 13 SP10 9 Cover O Ring 14 SP10 7 Base Plate O Ring 15 SP10MS 40B Indicator Stem O Ring 16 SP10MS 1B Base Plate 17 SP10MS 3C Micro Switch Screw x2 18 SP10MS 3K Micro Switch Washer x2 19 SP10MS 3L MS Bracket Screw x2 20 SP10MS 3B SP20 DPS Micro Switch x2 Dual Prox Switch x2 21 SP10MS 3A MS Mounting Block 22 SP10MS 3D MS Adjusting Bracket 23 SP10MS 3 Micro Switch Bracket 24 ...

Страница 40: ... 1BN Base Plate Nut 12 SP10 15BV SP10MS 15BV 1 8 I P Adapter Plug 13 SP110MS 1 Cylinder 14 SP10MS 14 SP10 14 1 4 Poly Tube Connector 15 SP10 9 Cover O Ring 16 SP10 7 Base Plate O Ring 17 SP10MS 40B Indicator Stem O Ring 18 SP10MS 1B Base Plate 19 SP10MS 3C Micro Switch Screw x2 20 SP10MS 3B SP20 DPS Micro Switch x2 Dual Prox Switch x2 21 SP10MS 3A Micro Switch Block x2 22 SP10MS 3D MS Adjusting Br...

Страница 41: ...nder 12 SP10MS 14 SP10 14 1 4 Poly Tube Connec tor x2 13 SP10 9 Cover O Ring 14 SP10 7 Base Plate O Ring 15 SP10MS 40B Indicator Stem O Ring 16 SP10MS 1B Base Plate 17 SP10MS 3C Micro Switch Screw x2 18 SP10MS 3B SP20 DPS Micro Switch x2 Dual Prox Switch x2 19 SP10MS 3A Micro Switch Block x2 20 SP10MS 3D MS Adjusting Bracket x2 21 SP110MS 3 Micro Switch Bracket 22 SP110MS 1A SP120MS 1A Micro Switc...

Страница 42: ...Nylon Cable Grip for 1 4 3 8 OD range SP10PRX SP20PRX SP30PRX SP110PRX SP120PRX SP 130PRX PROXIMITY SWITCH ITEM PART NUMBER DESCRIPTION 1 SP20 DPS Proximity Switches Dual Prewired A Bottom B Top 2 SP20PS PD Proximity Switch Indicator Stainless Steel Prox Dog with Set Screw 3 SP20 4P NPT 1 2 NPT Adapter to Female 4 Pin M12 SP20 FWC CONN Male M12 to Cable Adapter Included but Optional FEMALE 4 PIN M...

Страница 43: ...5 SP40B 3 SP40B 3 5 SP40B 4 Gasket for 1 5 Valve Gasket for 2 Valve Gasket for 2 5 Valve Gasket for 3 Valve 6 SP10 6 Stem O Ring 7 7RS SP160 7 Size 2E SP160 7 Size 2V SP160 7RS Size 2TS Shut off Stem EPDM Shut off Stem Viton Shut off Stem PTFE 8 SP13HC 2 5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 3 Valve 9 SP160 7 Size 1 Tee Body 10 SP160 9 S...

Страница 44: ...SP40B 2 5 SP40B 3 SP40B 3 5 SP40B 4 Gasket for 1 5 Valve Gasket for 2 Valve Gasket for 2 5 Valve Gasket for 3 Valve 6 SP10 6 Stem O Ring D7 D7RS SP160 77 Size 2E SP160 77 Size 2V SP160 77RS x 2TS Divert Plug Stem EPDM Divert Plug Stem Viton Divert Plug Stem PTFE 8 SP13HC 2 5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 3 Valve 9 SP160 7 Size 1 Te...

Страница 45: ...e 3 Bonnet 6 SP40B 2 5 SP40B 3 SP40B 3 5 SP40B 4 Gasket for 1 5 Valve Gasket for 2 Valve Gasket for 2 5 Valve Gasket for 3 Valve 7 SP10 6 Stem O Ring 8 8RS SP161 7 Size 2E SP161 7 Size 2V SP161 7RS Size 2TS Shut off Stem EPDM Shut off Stem Viton Shut off Stem PTFE 9 SP13HC 2 5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 3 Valve 10 SP160 7 Size 1...

Страница 46: ...r Body 6 SP40B 2 5 SP40B 3 SP40B 3 5 SP40B 4 Gasket for 1 5 Valve Gasket for 2 Valve Gasket for 2 5 Valve Gasket for 3 Valve 7 SP10 6 SP10 6 3 Stem O Ring Stem O Ring 3 Divert Only D8 D8RS SP161 77 Size 2E SP161 77 Size 2V SP161 77RS Size 2TS Divert Plug Stem EPDM Divert Plug Stem Viton Divert Plug Stem PTFE 9 SP13HC 2 5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for ...

Страница 47: ... Size 1 Body Bonnet 4 SP13Z 2 5 Bonnet Clamp 5 SP10 SP20 SP30 Actuator N O Actuator N C Actuator A A 10 SP160 7 1 5 9 Spring Clip SP165 ELBOW VALVES ITEM PART NUMBER DESCRIPTION 2 SP10 6 Stem O Ring 4 SP13Z 2 5 Bonnet Clamp 6 SP165 7 Size 2 Plug and Stem 7 SP165 7 Size 1 Body and Bonnet 8 SP161 4 Adapter Spool 9 SP110 SP120 SP130 Actuator N O Actuator N C Actuator A A 10 SP160 7 1 5 9 Spring Clip ...

Страница 48: ...P13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 3 Valve 6 SP40B 2 5 SP40B 3 SP40B 3 5 SP40B 4 Body Gasket for 1 5 Valve Body Gasket for 2 Valve Body Gasket for 2 5 Valve Body Gasket for 3 Valve 7 SP10 6 Stem O Ring 8 SP160 7 Size 2E SP160 7 Size 2V Plug and Stem EPDM Plug and Stem Viton 9 SP163R 7 Size 1 Tang Right Tee Body 10 SP163L 7 Size 1 Tang Le...

Страница 49: ...5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 3 Valve 6 SP40B 2 5 SP40B 3 SP40B 3 5 SP40B 4 Body Gasket for 1 5 Valve Body Gasket for 2 Valve Body Gasket for 2 5 Valve Body Gasket for 3 Valve 7 SP10 6 Stem O Ring 8 SP161 7 Size 2E SP160 7 Size 2V Plug and Stem EPDM Plug and Stem Viton 9 SP163R 7 Size 1 Tang Right Tee Body 10 SP163L 7 Size 1 Tang...

Страница 50: ...161 7 4 1 SP161 9 4 1 Tee Body Cross Body not shown 8 SP161 7 4 2E 120 SP161 7 4 2V 120 SP161 7 4 2E 110 SP161 7 4 2V 110 Plug and Stem N C EPDM Plug and Stem N C Viton Plug and Stem N O EPDM Plug and Stem N O Viton 9 SP161 77 4 3 Divert Bonnet 10 SP13HC 4 Upper Body Clamp 11 SP40 4 Upper Body Gasket 12 SP161 77 4 1 Upper Divert Body 13 SP161 77 4 2E 120 SP161 77 4 2V 120 SP161 77 4 2E 110 SP161 7...

Страница 51: ...5 2 Piston 3 SP10 0 5 2D SP20 0 5 2D Stem N O Stem N C 4 SP160 7 0 5 3 Bonnet 5 SP10 0 5 4 Cylinder Foot 6 SP10 0 5 5 Spring 7 SP10 0 5 6 Upper Stem O Ring 8 SP10 0 5 7 Lower Stem O Ring 9 SP10 0 5 8 Piston O Ring 10 SP10 0 5 9 Cylinder Foot O Ring 11 SP10 0 5 12 Stem Nut 12 SP13HC 2 Bonnet Clamp 13 SP10 14 Poly Tube Connector 14 SP10 15BV I P Adapter INCLUDED IN SP20 0 5 SK ACTUATOR SERVICE KIT I...

Страница 52: ...UT OFF AND DIVERT VALVES ITEM PART NUMBER DESCRIPTION KIT 1 SP10 0 5 SP20 0 5 SP30 0 5 Actuator N O Actuator N C Actuator A A 2 SP160 7 1 5 9 Spring Clip 3 SP13HC 1 5 Clamp 4 SP160 7 0 5 2OR Stem O Ring 5 SP160 7 0 5 2 Plug and Stem 6 SP40B 0 75 Bonnet Gasket 7 SP160 7 Size 1 Tee Body 8 SP160 77 Size 1 Divert Body 9 SP160 77 0 5 2 Divert Plug and Stem 10 SP160 9 Size 1 Cross Body ...

Страница 53: ...r must be energized in the appropriate direction to retract the stem seat and disassemble the valve body It will have two air fittings and no spring or normal de energized state See fig 6 7 Energize through fitting see fig 5 to open the valve FIG 8 SP 160 SHUTOFF VALVE DISASSEMBLY INSTRUCTIONS SP 160 SHUTOFF VALVE FIG 2 SP 160 SHORT STROKE SHUT OFF VALVE FIG 3 SP10 ACTUATOR NORMALLY OPEN FITTING S...

Страница 54: ...ill also help re assembly of the spring clip into the stem see fig 11 DISASSEMBLY INSTRUCTIONS SP 160 SHUTOFF VALVE 2 Once the body is removed remove gasket see fig 9 with a pick and replace FIG 9 SP 160 SHORT STROKE SHUT OFF VALVE GASKET FIG 11 SP 160 SHORT STROKE SHUT OFF VALVE SPRING CLIP VALVE STEM SP160 7 SIZE 2E SP160 7 SIZE 2V VALVE STEM SP160 7RS SIZE 2TS ...

Страница 55: ...gure 15 but continue to pry Replace the stem and seat see fig 17 or if the valve has a PTFE replacable seat see fig 18 keep stem and replace seat DISASSEMBLY INSTRUCTIONS SP 160 SHUTOFF VALVE FIG 13 GROOVES IN VALVE STEM AND ACTUATOR STEM SHOWN WITHOUT BONNET FOR REFERENCE FIG 14 FULLY INSTALLED SPRING CLIP REMOVE TO THE RIGHT AS ORIENTED IN THIS PHOTO FIG 15 SPRING CLIP HALFWAY REMOVED OR INSTALL...

Страница 56: ...KET HEAD CAP SCREWS FIG 20 BONNET AND CLAMP REMOVED SOCKET HEAD CAP SCREW SOCKET HEAD CAP SCREW FIG 21 SP160 SHORT STROKE SHUT OFF VALVE EXPLODED DIAGRAM BONNET SP160 7 SIZE 3 CLAMP SP13Z 2 5 5 The fluid side of the valve and the actuator are now totally separated and maintenance of the actuator can take place FIG 22 ACTUATOR ASSEMBLY FIG 23 ALL VALVE BODY FLUID END PARTS DISASSEMBLED ...

Страница 57: ...ove actuator clamp see fig 29 The spring is not long enough to be under tension while the actuator does not have air applied on an SP10 20 30 so this clamp can be removed safely by hand DISASSEMBLY INSTRUCTIONS SP 160 SHUTOFF VALVE ACTUATOR CLAMP SP13HC 4 FIG 25 SP10 SHORT STROKE ACTUATOR NORMALLY OPEN FIG 26 ACTUATOR FOOT AND ACTUATOR SHAFT PISTON SEPARATED FIG 27 SP10 SHORT STROKE ACTUATOR NORMA...

Страница 58: ...on SP10 2 from the actuator stem SP10 2D by holding the stem and removing the hex nut with an wrench Replace the upper stem O ring SP10 6 FIG 32 ACTUATOR STEM SP10 2D REMOVED FROM ACTUATOR PISTON SP10 2 FIG 34 UPPER STEM O RING SP10 6 REMOVED FROM ACTUATOR STEM SP10 2D FOOT O RING SP10 9 LOWER STEM O RING PSP10 7 FIG 33 SP10 SHORT STROKE ACTUATOR NORMALLY OPEN PISTON SP10 2 ACTUATOR STEM SP10 2D S...

Страница 59: ... to be disassembled NOTE Ensure that the bore cup on the actuator piston see fig 36 fits into the spring s OD guide or retaining flange depending on orientation FIG 37 SP10 ACTUATOR WITH SPRING ASSEMBLY PARTS RETAINING RING SP10 5R I D GUIDE SP10 5C BRASS BUSHING SP10 5E O D GUIDE SP10 5B RETAINING FLANGE SP10 5D SPRING AND CAGE ASSEMBLY SP10 5 SPRING SP10 5A ...

Страница 60: ... I P Adapter Plug 13 SP10MS 1 Cylinder 14 SP10MS 14 SP10 14 1 4 Poly Tube Connector 15 SP10 9 Cover O Ring 16 SP10 7 Base Plate O Ring 17 SP10MS 40B Indicator Stem O Ring 18 SP10MS 1B Base Plate 19 SP10MS 3C Micro Switch Screw x2 20 SP10MS 3K Micro Switch Washer x2 21 SP10MS 3L MS Bracket Screw x2 22 SP10MS 3B SP20 DPS Micro Switch x2 Dual Prox Switch x2 23 SP10MS 3A MS Mounting Block 24 SP10MS 3D...

Страница 61: ...e the microswitch bracket and cover The actuator stem see fig 2 has a special shaft on top to actuate the microswitches for feedback This shaft works through the top of the cylinder FIG 1 MICROSWITCH MODEL AND CIRCUIT INFORMATION FIG 3 MICROSWITCH RELATED PARTS HARDWARE AND O RINGS MICROSWITCH ASSEMBLY INSTRUCTIONS SP10MS SP10PRX SP20MS SP20PRX CYLINDER SP10MS 1 FIG 2 SP10MS SP10PRX SP20MS SP20PRX...

Страница 62: ...plate nut is large and requires a 1 5 16 socket and extension FIG 7 INSTALLATION OF BASE PLATE USING THE BASE PLATE NUT FIG 5 O RING INSTALLATION ON BASE PLATE MICROSWITCH ASSEMBLY INSTRUCTIONS SP10MS SP10PRX SP20MS SP20PRX BASE PLATE SP10MS 1B FIG 6 SP10MS SP10PRX SP20MS SP20PRX ACTUATOR DIAGRAM ACTUATOR STEM SP10MS 2D SP20MS 2D BASE PLATE O RING SP10 7 INDICATOR STEM O RING SP10MS 40B CYLINDER S...

Страница 63: ...ting Bracket FIG 8 MICROSWITCHES INSTALLED ON BRACKET AND BRACKET INSTALLED ON CYLINDER MICROSWITCH ASSEMBLY INSTRUCTIONS SP10MS SP10PRX SP20MS SP20PRX FIG 9 SP10MS SP10PRX SP20MS SP20PRX ACTUATOR DIAGRAM MICROSWITCH BRACKET SP10MS 3 MICRO SWITCHES X2 SP10MS 3B MICROSWITCH SCREWS X2 SP10MS 3C MICROSWITCH BRACKET SCREWS X2 SP10MS 3L MICROSWITCH WASHERS X2 SP10MS 3K MICROSWITCH MOUNTING BLOCK SP10MS...

Страница 64: ...witches screws microswitch mounting blocks and microswitch adjusting bracket happens see fig 12 The mounting block spaces the microswitches into the center of the actuator stem and the adjusting bracket acts as a nut and sandwiches the microswitches to the microswitch bracket Do not install the lower microswitch too low as this will make installation more difficult and it will need to be adjusted ...

Страница 65: ... in the bracket so that it is concentric with the actuator stem as shown in Fig 13 FIG 13 MICROSWITCH BRACKET INSTALLATION MICROSWITCH ASSEMBLY INSTRUCTIONS SP10MS SP10PRX SP20MS SP20PRX FIG 14 SP10MS SP10PRX SP20MS SP20PRX ACTUATOR DIAGRAM CYLINDER SP10MS 1 MICROSWITCH BRACKET SP10MS 3 MICROSWITCH BRACKET SCREWS X2 SP10MS 3L MICROSWITCH WASHERS X2 SP10MS 3K ACTUATOR STEM SP10MS 2D ...

Страница 66: ...screws but do not fully tighten Test the actuator and watch the actuator stem go up and down The actuation zone as shown in fig 15 must depress the according microswitch when the valve is open and closed Figure 15 shows the actuator stem up or the valve open Set the microswitch such that the roller is in the center of the actuation zone the switch is not too far or firmly depressed thus risking da...

Страница 67: ...he microswitch housing washer goes onto the stud on the bracket and then the acorn nut see fig 19 FIG 17 MICROSWITCH HOUSING AND HARDWARE FIG 18 MICROSWITCH HOUSING INSTALLED MICROSWITCH ASSEMBLY INSTRUCTIONS SP10MS SP10PRX SP20MS SP20PRX FIG 19 SP10MS SP10PRX SP20MS SP20PRX ACTUATOR DIAGRAM MICROSWITCH HOUSING WASHER SP10MS 1CW ACORN NUT SP10MS 1C MICROSWITCH BRACKET SP10MS 3 ...

Страница 68: ...81 2 937 0 625 00 SP160 7 3 2 6 35 3 438 0 625 Divert Valves 7 438 1 937 0 625 8 499 2 437 0 625 9 487 2 937 0 625 10 56 3 438 0 625 6 062 2 437 0 625 7 022 2 937 0 625 ml 8 351 3 438 0 625 m tlD 14 969 4 438 0 875 11 094 4 438 0 875 9 687 2 437 0 625 10 874 2 937 0 625 I 12 18 3 438 0 875 00 20 701 4 438 0 875 SP160 77 l 5 2 SP160 77 2 2 SP160 77 2 5 2 SP160 77 3 2 Long Stroke Shut Off Valves SP1...

Страница 69: ...Cage Assembly 6 SP10 6 Upper Stem O Ring 7 SP10 7 Lower Stem O Ring 8 SP10 8 Piston O Ring 9 SP10 9 Foot O Ring 10 SP13HC 4 Actuator Clamp 11 SP10 12 Stem Nut 12 12395 X 1612 Range Spring 13 73N12F Valve Postioner 14 SP10MS 14 Poly Tube Connector 15 SP10 15BV Breather Vent Plug INCLUDED IN SP20 SK ACTUATOR SERVICE KIT INCLUDED IN SP20 RBK SIZE VALVE SERVICE KIT SP10VPD DIRECT ACTING VALVE POSITION...

Страница 70: ...0VP 2DA Actuator Stem 4 SP10 4 Actuator Foot 5 SP10 5 Spring and Cage As sembly 6 SP10 6 Upper Stem O Ring 7 SP10 7 Lower Stem O Ring 8 SP10 8 Piston O Ring 9 SP10 9 Foot O Ring 10 SP13HC 4 Actuator Clamp 11 SP20VP 2DB Range Spring Stem 12 12395 X Range Spring 13 73NFR Valve Postioner 14 SP10 14 Poly Tube Connector 15 SP10MS 14 Poly Tube Connector 16 SP10MS 14 Tee Poly Tube Tee 17 1 4 Poly Tube SP...

Страница 71: ... 2 SP160 7MT Size 2 Plug and Stem Multi Taper Plug and Stem Straight Taper 8 SP13HC 2 5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 3 Valve 9 SP160 7MT Size 1 Tee Body 10 SP160 9MT Size 1 Cross Body INCLUDED IN SP20 RBK SIZE VALVE SERVICE KIT MICROMETER HANDLE ITEM PART NUMBER DESCRIPTION KIT A SP10 12 Stem Nut B SP160 7MH SW Space Washer C SP16...

Страница 72: ...andle 2 SP13Z 2 Bonnet Clamp 3 SP160 7 1 5 3 Bonnet 4 SP160 7 1 5 9 Spring Clip 5 SP10 6 Stem O Ring 6 SP13HC 2 Body Clamp 7 SP160 7M 1 Size 2 Plug and Stem 8 SP160 7M 1 Size 1 Body 9 SP40B 2 5 Body Gasket INCLUDED IN SP20 RBK SIZE VALVE SERVICE KIT SP160 7M MICRO FLOW MODULATING VALVE ALL MICRO FLOW VALVES HAVE 1 INCH CLAMP END CONNECTIONS PLUG OPTIONS ...

Страница 73: ...lor Adapter Small Taylor Adapter 5 SP13Z 2 5 Bonnet Clamp 6 SP160 7 Size 3 Bonnet 7 SP13HC 2 5 SP13HC 3 SP13HC 3 5 SP13HC 4 Clamp for 1 5 Valve Clamp for 2 Valve Clamp for 2 5 Valve Clamp for 4 Valve 8 SP40B 2 5 SP40B 3 SP40B 3 5 SP40B 4 Gasket for 1 5 Valve Gasket for 2 Valve Gasket for 2 5 Valve Gasket for 3 Valve 9 SP10 6 Stem O Ring 10 SP160 7M Size 2 Plug and Stem Multi Taper SP160 7MT Size 2...

Страница 74: ...s lower port AND the positioner s supply port This is shown in Figure 1 The hose configuration on the SP20 120 connects the Moore positioner s supply port to the actuator s lower port AND the positioner s supply port This is shown in Figure 2 MODULATING ACTUATOR ASSEMBLY INSTRUCTIONS A B B A B B SP10 110VPD VALVE POSITIONER DIRECT NORMALLY CLOSED SP20 120VPR VALVE POSITIONER REVERSE NORMALLY OPEN ...

Страница 75: ...lve operation Tapped Exhaust The Model 73N Positioner can be ordered with a tapped exhaust port This feature permits piping of the pilot exhaust to a safe atmosphere on applications where noxious gases are used as a control medium instead of air USM On actuators with small topworks and a low volume a special hi response positioner may be used This positioner is denoted by the letters USM in the mo...

Страница 76: ...ntering diaphragm for the gasket if the P N 12388 6412 or 12395 6412 range spring is used 4 Place the positioner range spring seat on the center nut of the positioner diaphragm assembly 5 Hold the spring seat and guide the positioner and seat onto the range spring 6 Orient the positioner for desired location of connections 7 Insert mounting screws and washers and tighten screws PNEUMATIC CONNECTIO...

Страница 77: ...be compatible with the materials used in the construction of the positioner Wetting of these materials by such an oil mist or oil vapor etc may cause them to deteriorate This may ultimately result in failure of the positioner The following materials are in contact with supply air Aluminum Brass Stainless Steel Neoprene and Buna N The requirements for a quality air supply can be found in the Instru...

Страница 78: ...78 MOORE POSITIONER INSTALLATION AND SERVICE INSTRUCTIONS ...

Страница 79: ...h the desired span The proper spring will be found at the intersection of these two columns Series 4090 and 12395 range springs are available for stroke range tolerances of 10 Series 12388 range springs are available at extra cost for stroke range tolerances of 5 MOORE POSITIONER INSTALLATION AND SERVICE INSTRUCTIONS SPECIAL NOTES 1 All range springs are identified as Part No P N 12395 _ from tabl...

Страница 80: ...12 1424 1024 5 8 3212 2412 2012 1612 1212 1012 1624 1224 1024 3 4 3612 2812 2412 1812 1412 1212 1464 1224 7 8 4412 3612 2812 2012 1812 1412 2024 1624 1424 1 4812 4012 3212 2412 2012 1612 2424 2024 1624 1 1 8 5612 4412 3612 2812 2012 1812 2024 1 1 4 6412 4812 4012 3212 2412 2012 2824 2424 2024 1 1 2 6412 4812 3612 2812 2412 4024 2824 2424 1 5 8 6412 4812 4012 3212 2612 4024 3224 1 3 4 6412 5612 441...

Страница 81: ...op cover 3 Remove the retaining nut 4 Remove the plunger 5 Use a non abrasive solvent to clean the plunger 6 Replace the plunger 7 Replace and tighten the retaining nut 8 Replace the top cover DISASSEMBLY REFER TO PARTS LIST 1 Loosen the six socket head mounting screws holding the positioner to the actuator 2 Remove the positioner 3 Remove the two body screws holding the diaphragm stack assembly t...

Страница 82: ...nge Black Orange 1812 Gray White Gray Yellow Brown Yellow 2012 Gray Brown Gray Orange White Orange 2024 Brown Gray Brown Purple None Purple 2412 Gray Black Gray Yellow None Yellow 2424 Black Gray Black Yellow Purple Yellow 2612 Gray Green Gray Orange Brown Orange 2812 Gray Purple Gray Green Brown Green 2824 Purple Gray Purple Green Red Green RANGE SPRING COLOR CODES 12388 ITEM 12395 ITEM LH WOUND ...

Страница 83: ...ll lift off of the actuator FIG 3 MOORE POSITIONER SOCKET HEAD CAP SCREWS FIG 4 MOORE POSITIONER CORK GASKET AND RANGE SPRING CAP 2 The cork gasket range spring see figure 6 and brass range spring cap can be removed FIG 5 MOORE POSITIONER ASSEMBLY REMOVED FROM ACTUATOR ASSEMBLY MOORE POSITIONER REMOVAL RANGE SPRING 12395 X 1612 FIG 6 SP10VPD DIRECT ACTING VALVE POSITIONER ...

Страница 84: ... stem assembly can be removed See page 57 in the shutoff valve actuator disassembly section for final instructions for removal and replacement of the rest of the actuator components FIG 7 ACTUATOR FOOT REMOVED FIG 8 PISTON SPRING AND ACTUATOR STEM REMOVED SPRING PISTON AND ACTUATOR STEM REMOVAL ...

Страница 85: ...APPLIED AND VALVE REMOVED 2 Remove the valve clamp to gain access to the bonnet gasket see fig 2 Figure 3 shows the valve body removed with air still applied to the actuator putting the valve plug in the open position FRACTIONAL VALVES ASSEMBLY INSTRUCTIONS VALVE CLAMP SP13HC 1 5 BONNET GASKET SP40B 0 75 VALVE PLUG SP160 7 0 5 2 VALVE PLUG SP160 77 0 5 2 FIG 2 FRACTIONAL SHUT OFF AND DIVERT VALVES...

Страница 86: ...m the actuator by removing the bonnet clamp Once the bonnet is removed hold the actuator stem see fig 7 in a non marring vise or utilize the spring clip slot Pull on the actuator housing cylinder see fig 7 and it will slide out of the cylinder foot FIG 8 BONNET REMOVED FIG 9 CYLINDER REMOVED FROM ACTUATOR FOOT FRACTIONAL VALVES ASSEMBLY INSTRUCTIONS SPRING CLIP SP160 7 1 5 9 BONNET SP160 7 0 5 3 P...

Страница 87: ...2 7 Once the nut is removed the actuator stem see fig 15 can be removed to gain access to and replace Upper stem O ring Lower stem O ring Piston O ring Cylinder foot O ring FIG 12 STEM NUT REMOVED FIG 14 ACTUATOR FULLY DISASSEMBLED FIG 13 FRACTIONAL ACTUATOR EXPLODED DIAGRAM ACTUATOR STEM SP10 0 5 2D N O SP20 0 5 2D N C UPPER STEM O RING SP10 0 5 6 FIG 15 FRACTIONAL ACTUATOR EXPLODED DIAGRAM PISTO...

Страница 88: ... stem nut with a wrench FIG 1 MICROMETER ACTUATOR ASSEMBLED 2 With the stem nut removed the micrometer stem can be removed out the bottom of the actuator assembly FIG 4 MICROMETER STEM REMOVED FIG 3 STEM NUT AND WASHER FIG 2 MICROMETER ACTUATOR STEM NUT MICROMETER VALVES ASSEMBLY INSTRUCTIONS FIG 5 MICROMETER HANDLE EXPLODED DIAGRAM STEM NUT SP10 12 MICROMETER STEM SP160 7MTH 2D SPACE WASHER SP160...

Страница 89: ...ND BONNET 3 Replace the bonnet O ring MICROMETER VALVES ASSEMBLY INSTRUCTIONS FIG 7 MICROMETER BONNET FIG 8 MICROMETER HANDLE EXPLODED DIAGRAM MICROMETER BONNET SP160 7MTH 3 MICROMETER HANDLE SP160 7MH H BONNET O RING SP160 7MH 40 ...

Страница 90: ...in Section A above No transportation for returned or replaced items will be paid by the Company unless written approval for transportation charges is given by the Company C COMPONENTS NOT MANUFACTURED BY THE COMPANY Components not manufactured by the Company but furnished as part of its equipment will be warranted by the Company only to the extent of the component manufacturer s warranty D REPAIR ...

Страница 91: ...VALVES IOM REV 8 22 ...

Отзывы: