Thermo S 160/230/300/350/400
5 Troubleshooting and error correction
519
5.5.14 Circulating pump inspection
The safety device of the circulating pump may never be
pulled, while the pump is running.
Inspection using SST diagnosis
t
Disconnect the heater from the vehicle electrical
system.
t
Disconnect the temperature sensor plug and connect
the test plug to the adapter wiring harness.
t
Check the electrical connections as well as the
cooling system for leak-tightness.
t
Connect the heater to the vehicle electrical system.
t
Connect the SST diagnosis adapter to the heater and
a PC via the interface in the heater wiring harness.
Start SST diagnosis, establish connection to the
heater and open the Component Test menu.
t
Select and start the circulating pump in the
Component Test menu and start the component test.
t
After the test is completed, exit SST diagnosis
as needed.
t
Disconnect the heater from the vehicle electrical
system.
t
Disconnect the test plug and reconnect the
temperature sensor plug.
t
Connect the heater to the vehicle electrical system.
CAUTION
Содержание Thermo S 160
Страница 2: ......
Страница 6: ...1 Introduction Thermo S 160 230 300 350 400 4...
Страница 11: ...S o m r e h T n o i t c u d o r t n I 1 160 230 300 350 400 105...
Страница 49: ...5 Troubleshooting and error correction Thermo S 160 230 300 350 400 520...
Страница 55: ...r e h T s m a r g a i d c i t a m e h c S 6 mo S 160 230 300 350 400 606...
Страница 71: ...9 Modifications and retrofits Thermo S 160 230 300 350 400 902...
Страница 73: ...10 Packing storage shipping Thermo S 160 230 300 350 400 1002 Empty page for notes...
Страница 74: ...x i d n e p p A A 0 0 4 0 5 3 0 0 3 0 3 2 0 6 1 S o m r e h T A 1 Appendix A Periodic maintenance...