SIGNIFICATO
COMMENTO
2
1.4 SERVICING REQUESTS
For any information regarding the use, maintenance and installation, please contact the Spencer Customer Care Service on 0039 0521 541111 -
Fax 0039 0521 541222 e-mail: [email protected] or write to Spencer Italia S.r.l. - Strada Cavi, 7 - 43044 Collecchio (Parma) - ITALY.
1.5 DEMOLITION
Follow the actual regulations.
1.6 LABELLING
The serial number as indicated below can be found on each appliance and must not be removed or covered. In order to facilitate assistance
please indicate or communicate the serial number (SN) or lot number (LOT) on the label.
2.3 CONTRAINDICATIONS AND SIDE EFFECTS
The use of this device, if used as described in this manual, does not present any contra-indications or collateral effects.
2
WARNINGS
2.1 GENERAL WARNINGS
•
Before carrying out any kind of operation on the appliance, the operator must carefully read the enclosed instructions, paying particular attention to
the correct safety precautions and to the procedures to be followed for installation and for correct use.
•
In the case of any doubts as to the correct interpretation of the instructions, please contact Spencer Italia S.r.l. for any necessary clarifications.
•
Regularly check the appliance. Carry out the prescribed maintenance in order to keep the appliance in good condition and to guarantee correct func-
tioning and a long life.
•
In the case of any abnormalities or damage to the appliance, which could jeopardize the functioning, and the safety, the appliance must be immedia-
tely removed from service.
•
Do not alter or modify in any way the appliance; any such interference could cause malfunctions and injury to the patient and/or rescuer.
•
The appliance must not in any way be tampered with, in such cases all responsibility will be denied for any malfunctions or eventual injuries caused
by the appliance itself.
•
Who modifies or has modified, prepares or has prepared medical appliances in such a way that they no longer serve the purpose for which they were
intended, or no longer supply the intended service, must satisfy the valid conditions for the introduction onto the market.
•
Ensure that all the necessary precautions are taken in order to avoid hazards that can arise as the result of contact with blood or body fluids.
•
Handle with care.
2.2 SPECIFIC WARNINGS
The product must be used by medical personnel only.
1
GENERAL INFORMATION
1.1 AIM AND CONTENTS
The aim of this manual is to supply all the information necessary so that the client, will gain information regarding adequate use of the applian-
ce, and be capable of using the instrument in the most autonomous and secure way possible. This includes information regarding technical
aspects, functioning, maintenance, spare parts and safety.
1.2 CONSERVATION OF THE INSTRUCTION MANUAL
The instruction and maintenance manual must be kept with the product, inside the specially provided container and above all, away from any
substances or liquids which could compromise perfect legibility.
1.3 SYMBOLS USED
Thank you for choosing a Spencer product
SYMBOL
3.2 MAIN COMPONENTS
1 I.V. holder body
2 Block
switch
3 Aluminium
tube
4 Adjustment ring nuts
5 Nylon
hooks
6 Support strap for bags and bottles
3 DESCRIPTION OF PRODUCT
3.1 INTENDED USE
The TRACK 5 telescopic IV holder for Cross/Carrera/Enduro/Alto/
b
asket stretchers, is a strong and handy aluminium pole which is easily
attached to the stretcher. Folded up, in the resting position the IV holder is attached to the frame of the stretcher. Just one simple movement is suf-
ficient to place it in the vertical position at the desired height. On the end of the pole there are two strong nylon hooks for attachment of up to 2 I.V. liquid
bags or bottles for a maximum loading of 1 kg. The system is completed with an elastic strap with Velcro® closure which permits the attachment of the
I.V. bag or bottle to the pole and avoids their movement.
MEANING
Fig. 1
SYMBOL
/ LOT / CE
General or specific warnings
Lot number
The product is compliant with the specifications of the Directive 93/42/CEE