XRV 160kV Overview:
XRV160kV Rear Panel
The 160kV XRV Generator measures a compact
7.16” W x 10.09” x H 24” D (excluding handles).
The rear of the chassis has all of the necessary
connectors for power input, controls, monitoring,
and kV output. Each connector on the rear panel
is clearly marked for installation purposes. The
main and auxiliary input includes an Amphenol
style mating connector with an additional DB-25
pin connector for the I/O analog connection. The
high voltage output mates with a standard R-24
type connector. These are available from Spellman
High Voltage Corp. in different lengths and configurations for installation of the X-ray tube. Standard
Graphical User Interface (GUI) software is included with the XRV 160 Generator. A personal PC is
required for installation. The user has the option of connection to a USB, Ethernet or Com Port. The
control and monitoring of the XRV160 also includes an analog I/O connector for custom configurations.
An additional optional touch screen controller (XRVC) is also available from Spellman High Voltage Corp..
4kW Units
Содержание XRV Sub-system
Страница 1: ...SPELLMAN HIGH VOLTAGE XRV SUBSYSTEM INSTALLATION MANUAL ...
Страница 13: ...Page 13 of 98 118157 001 Rev C XRV 160kV Overview 400Vac 3Ø Input ...
Страница 17: ...Page 17 of 98 118157 001 Rev C XRV225kV Overview XRV225 400Vac 3Ø 6kW Unit ...
Страница 21: ...Page 21 of 98 118157 001 Rev C XRV450 Overview XRV450 Bipolar Cathode Generator ...
Страница 22: ...Page 22 of 98 118157 001 Rev C XRV450 Overview XRV450 Bipolar Anode Generator ...
Страница 25: ...Page 25 of 98 118157 001 Rev C I O System Interface Box Overview I O System Interface Box Front Panel Detail ...
Страница 28: ...Page 28 of 98 118157 001 Rev C XRVC Controller Overview XRVC Controller Rear Panel Detail ...
Страница 34: ...Page 34 of 98 118157 001 Rev C XRV Unipolar System Diagram Typical Unipolar System Minimal Requirements ...
Страница 36: ...Page 36 of 98 118157 001 Rev C XRV Bipolar System Diagram Typical Bipolar System Minimal Requirements ...
Страница 51: ...Page 51 of 98 118157 001 Rev C System Grounding Detail and HV Cable Connections ...
Страница 58: ...Page 58 of 98 118157 001 Rev C Interlock Communication Connections Unipolar Basic RS 232 Cable ...
Страница 59: ...Page 59 of 98 118157 001 Rev C Interlock Communication Connections Unipolar Basic Ethernet Cable USB Cable ...
Страница 66: ...Page 66 of 98 118157 001 Rev C ...
Страница 67: ...Page 67 of 98 118157 001 Rev C Power Source Connections Unipolar Basic ...
Страница 68: ...Page 68 of 98 118157 001 Rev C Power Source Connections Unipolar Basic ...
Страница 72: ...Page 72 of 98 118157 001 Rev C Power Connections I O System Interface Box ...
Страница 76: ...Page 76 of 98 118157 001 Rev C Main Input Power Connections I O System Interface Box ...
Страница 77: ...Page 77 of 98 118157 001 Rev C I O Subsystem Interface Box System Diagram ...
Страница 82: ...Page 82 of 98 118157 001 Rev C Flash Drive USB installation Step 1 Flash Drive USB installation Step 2 ...
Страница 83: ...Page 83 of 98 118157 001 Rev C Flash Drive USB installation Step 3 Flash Drive USB installation Step 4 ...
Страница 89: ...Page 89 of 98 118157 001 Rev C X Ray Tube Filament Calibration Setup ...