spega 341 298 Скачать руководство пользователя страница 34

Manual for ombra BST
LON slat angle automat
Order No.: 341 298

Transmitter ID

individual, unique 32-bit transmitter identification for 
wireless transmitters, based on EnOcean technology

UCPT

user configuration property type

UNVT

user network variable type

VDE

‚VDE Verband der Elektrotechnik, Elektronik und 
Informationstechnik e.V.‘
Association for Electrical, Electronic & Information 
Technologies

Version 1.00

Page 34 / 34

08.09.2020

Содержание 341 298

Страница 1: ...Manual for ombra BST LON slat angle automat Order No 341 298 Technical manual ombra BST Version 1 00 Radevormwald 08 09 2020 Version 1 00 Page 1 34 08 09 2020...

Страница 2: ...n 5 2 Product description 6 2 1 Technical Data 7 2 2 Mounting 9 2 3 Installation 11 2 4 Operation 11 3 Applications 12 3 1 Application data 12 4 Set up a device 13 5 Device functions 14 5 1 Slat track...

Страница 3: ...se store this manual in a location which is easily accessible to all users 1 1 Using the manual The manual is aimed at all persons concerned with the planning installation commissioning and maintenanc...

Страница 4: ...rves the right to refuse liability for damage to the product Additionally spega shall not be liable for consequential damage and or injury to people or property in such cases 1 4 Explanation of used p...

Страница 5: ...embled and installed by trained personnel only Operation of the device is determined by the application software Only software which has been approved by spega should be used for this device The syste...

Страница 6: ...automatic system determines the position of the sun azimuth and elevation for each facade segment depending on the time of day and adjusts the length and angle of the blinds in an adjustable cycle as...

Страница 7: ...ements Service button sending the Neuron ID operation via micro buttons on the front Other turn push button made of aluminium for menu operation Display elements Display alphanumeric 4 x 16 characters...

Страница 8: ...25 C 55 C Transport temperature 25 C 70 C Relative humidity 5 93 w o condensation Height of use up to 2000 m above sea level Safety Electrical isolation SELV EN 60 950 Protection class I IEC 536 VDE...

Страница 9: ...guidelines regulations and provisions of the respective country must be observed when planning and installing electrical systems The device specifications must be observed The device function is deter...

Страница 10: ...Manual for ombra BST LON slat angle automat Order No 341 298 Version 1 00 Page 10 34 08 09 2020...

Страница 11: ...arated integration For configuration use the corresponding LNS plug in on the Internet at www spega com Operation The operation is carried out via the rotary push button on the front panel Turning the...

Страница 12: ...untracking Group ombra BST SC341298EC_14 1 1 1 15 5 3 1 Application data In the spega device template manager you can select the required application In this way the required application files resourc...

Страница 13: ...e for this purpose which you can start as a plug in on your project You will find the device in the listed categories Category Device Weather sensor technology and automatics ombra BST Rev 2 All avail...

Страница 14: ...glare control strategy If the upper brightness limit is exceeded for longer than the parameterizable switch on delay the slat tracking system positions the blind in the parameterized extension length...

Страница 15: ...vidual compromise between maximized daylight yield and number of slat tracking movements per day Direct solar radiation Only direct sunlight can cause glare In order to be able to detect this reliably...

Страница 16: ...occupied time of the building Information on positioning Parameterizable sun position tracking for individual needs The frequency of the control of the slat tracking as well as the minimum change of t...

Страница 17: ...s possible to leave the length unchanged and only move to a certain slat angle For example the blinds can be set to maximum visibility slat angle 0 in case of temporary clouds This avoids any disturbi...

Страница 18: ...software of the device provides a total of 23 objects functional units These include 15 suntracking controller objects whose output variables can be used to communicate the calculated slat angle to th...

Страница 19: ...Manual for ombra BST LON slat angle automat Order No 341 298 The important settings can now be made in the device plug in Version 1 00 Page 19 34 08 09 2020...

Страница 20: ...298 In addition to building data such as time zone or geographical position the data of the individual facades are also specified here The individual facades can then be assigned to the individual Su...

Страница 21: ...automat Order No 341 298 The ombra BST now continuously calculates the optimum slat angle based on the entered parameters and makes this available to the LON network via the output network variables...

Страница 22: ...Manual for ombra BST LON slat angle automat Order No 341 298 6 2 Shading correction The plug in for configuring the Shading correction is started here Version 1 00 Page 22 34 08 09 2020...

Страница 23: ...ual for ombra BST LON slat angle automat Order No 341 298 All objects within the project which represent a spega blind actuator channel are automatically displayed here Version 1 00 Page 23 34 08 09 2...

Страница 24: ...Manual for ombra BST LON slat angle automat Order No 341 298 Next a New facade is configured Version 1 00 Page 24 34 08 09 2020...

Страница 25: ...rder No 341 298 A facade view with the individual windows axes and floors is now created in the right window according to the configuration In the lower area the appropriate settings can be made for e...

Страница 26: ...Manual for ombra BST LON slat angle automat Order No 341 298 The individual blind objects are now assigned to the corresponding windows via Drag and Drop Version 1 00 Page 26 34 08 09 2020...

Страница 27: ...bjects which is available in every spega e control blind actuator object On the basis of this information each individual object knows at all times whether it is currently in shadow or not and thus al...

Страница 28: ...entral function the use of group objects is suitable for further distribution to the actuator objects Node Slat tracking SunblindGroup nviSgValue Group facade A SuntrackingCtrl nvoStAutoSetting Facade...

Страница 29: ...utomat Order No 341 298 The number of sun protection objects per facade is not limited When using different sun protection functions the priority control should be used to give priority to the functio...

Страница 30: ...ators are located The NodeObject provides the current sun position to all sun protection actuators of the node Node SunblindActuator Sunshade actuator SunPosition nvoSun Sun Tracking Shading correctio...

Страница 31: ...n of the automatic slat angle control This plug in ensures that each sun protection actuator involved receives its relevant data for shading taking into account the current position of the sun to dete...

Страница 32: ...nced cordless telecommunications DIN Deutsches Institut f r Normungen e V German Institute for Standardization D Sub 9pole design of a connector system for data connections EN European Norm EnOcean su...

Страница 33: ...twork variable PDA personal digital assistent Plug in tool to configure commission and log components of applications Ressource Files files including definitions of interface components which can be u...

Страница 34: ...identification for wireless transmitters based on EnOcean technology UCPT user configuration property type UNVT user network variable type VDE VDE Verband der Elektrotechnik Elektronik und Informatio...