Figure A:  Controls

Fault:

 

This indicates that the cables are connected improperly. 

Immediately disconnect the cables and connect them

properly to prevent damage to the battery.

 

   

This will light up red when the power is connected.  

This will light up green when the battery is fully charged.

The LED light can only light up either in red or green once 

a time.

 

Setting Switch:

  

Use this to switch between charging and start modes  

and change the output amperage.

Battery Type Switch:

 

Use this to set the battery type:

 Set to Regular for flooded and maintenance-free batteries.

 Set to AGM for Absorbed Glass Mat batteries.

WARNING!  TO PREVENT EXPLOSION: 
DO NOT USE WITH GEL BATTERIES.

Charge Meter (10 amp charge mode only):

Figure B:  DISCHARGED BATTERY

Initial charge current to the battery is at the maximum.

FIGURE C:  BATTERY ALMOST FULLY CHARGED

Charge current to the battery is reduced.

Figure D:  FULLY CHARGED BATTERY

Charge current to the battery is minimal and the green 

LED is on.

Charging:

Floating:

WARNING:

 TO PREVENT SERIOUS INJURY: DO NOT PLUG IN CHARGER UNTIL DIRECTED TO DO SO.

Sometimes conditions such as a cold battery, a sulfated battery, or a deeply discharged lead calcium 

battery may cause Charge Meter to read near a full charge when charging process is only beginning.

Note:

 The Charge Meter shows the amount of current being drawn from the charger. It does not show what the 

charger is capable of delivering. When  the battery is fully charged and registering 100% on the Charge Meter, 

a small charge will continue to move from the charger to the battery. If the charger is not disconnected from the 

battery, eventually heat build up will cause the battery acid to boil and overcharge the battery causing damage to 

the battery.  Monitor battery charging progress constantly and if battery gets warm, stop charging it immediately.

Type Switch

Fault

Floating

Charging

Setting Switch

Charge Meter

Clamp

Содержание 07215

Страница 1: ...emble maintain install or operate this product Observe all safety information to protect yourself and others Failure to observe the instructions may result in property damage and or personal injury Please keep instructions for future reference For warranty purchases please keep your dated proof of purchase File or attach to the manual for safe keeping For Customer Service Call 1 800 348 5004 or e ...

Страница 2: ...ating of charger 6 Do not operate this charger with a damaged cord or plug Replace the cord or plug immediately 7 Do not operate charger if it has received a sharp blow been dropped or otherwise when service or repair is required Incorrect reassembly may result in a ri 9 To reduce risk of electric shock unplug charger from outlet before attempting any maintenance or cleaning Recommended minimum AW...

Страница 3: ...gs on these products and on engine 11 Personal Precautions a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching eyes while working near battery d If battery acid co...

Страница 4: ...disconnect the charging clamps Immediately ventilate the room by opening windows and doors Do not switch on an electrical fan When the air has cleared of gas unplug the unit from the electrical outlet b Charge the battery in a well ventilated area c To prevent sparking due to electrostatic discharge never wear clothes made of synthetic materials when charging the battery ignite the gasses caused b...

Страница 5: ...CHARGED BATTERY Initial charge current to the battery is at the maximum FIGURE C BATTERY ALMOST FULLY CHARGED Charge current to the battery is reduced Figure D FULLY CHARGED BATTERY Charge current to the battery is minimal and the green LED is on Charging Floating WARNING TO PREVENT SERIOUS INJURY DO NOT PLUG IN CHARGER UNTIL DIRECTED TO DO SO Sometimes conditions such as a cold battery a sulfated...

Страница 6: ...er 5 10 minutes needle does not move off high end the battery probably has a short circuit Unplug charger and discontinue use Have battery checked by a qualified technician COLD BATTERIES begin charging at a low rate increase as battery reaches a normal temperature then rate will decrease normally DO NOT CHARGE A FROZEN BATTERY BATTERIES WITH HYDROMETER EYE Do not depend on hydrometer eye to deter...

Страница 7: ...ARNING TO PREVENT EXPLOSION DO NOT USE WITH GEL BATTERIES 1 Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than NEGATIVE NEG N post 2 Attach at least a 24 inch long 6 gauge AWG insulated battery cable to NEGATIVE NEG N battery post 3 Connect POSITIVE RED charger clip to POSITIVE POS P post of battery 4 Position yourself and free end of cable as far away f...

Страница 8: ...damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use Maintenance Instructions Troubleshooting Problem Possible Causes Likely Solutions Charger will not start 1 Cord not connected 2 No power at outlet 3 Clamps are not securely connected to battery terminals 1 Check that cord is plugged in 2 Check power at outlet If outlet is unpowered turn off charge...

Страница 9: ...alterations or a lack of maintenance FOT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Shipping and handling charges may apply If a defect is found FOT will e...

Отзывы: