Easy Flash Module 3.0 User Manual
EFM 3.0 V1.1 Speed Turtle Engineering LLC Page | 10
•
Park
: Five blue blinks followed by a short delay
Troubleshooting
Troubleshooting begins with determining if you have the latest EFM 3.0 module software. Use the
following steps to check your software level:
1.
Check for the latest EFM 3.0 software version on the support page of
SpeedTurtleEngineering.com
2.
Ensure the module has the latest software by checking the software version number using
the
STE Configuration Utility
.
3.
If a newer software is available on the website, update your module using the
STE
Configuration Utility
.
After ensuring you have the most up to date software, reinstall the module in the vehicle. If the
problem persists, the next step is to determine the current module mode. This can be done by
viewing the status LED. The
Status LED Mode
section of this document describes the light pattern for
all 12 module modes. Once the module mode has been determined Table 1 can be used.
Table 1
Troubleshooting Matrix
Issue
Troubleshooting Action
Module stuck in Initialize
or Startup 1
–
4 modes
•
Check all connections
•
Ensure the vehicle is running
•
With the vehicle off disconnect the white connector for 30
seconds and reconnect
Module in Vehicle Not
Supported mode
•
Ensure your vehicle is contained on the supported vehicle
list
Module in Normal mode
and will not activate
•
Check that the switch interface harness is securely inserted
•
If using the voltage input harness, ensure there is 5-17 volts
applied to the input wire