Spectrum Technologies WatchDog 3611A Скачать руководство пользователя страница 8

8

 

SpecWare software version 9.03, and above support the Watch-

Dog A160 logger. Previous builds of SpecWare 9 can be updated 

via  the  free  downloads  available  at  www.specmeters.com.  The 

software version can be checked by selecting 

About SpecWare

” 

from the Help menu. 

 

 

Complete  details  on the  software  are  included  in the  SpecWare 

Software  manual  which  is  available  as  a  pdf  document  on  the 

installation CD (and accessible via the Help menu). The following 

sections summarize the most commonly used functions.

 

 

Initializing the Serial Number and  Logger Type

 

The  first  time  that  an  A

-

Series  logger  is  read  by  SpecWare,  an 

initialization screen will open. Enter the serial number printed on 

the bottom of the logger. Because you have an A160, the A125/

A130 options are ignored.

 

Logger Location Names

 

SpecWare maintains a list of A

-

Series logger serial numbers and 

their corresponding location names. As a result, the first time an 

A

-

Series  logger  is  connected  on  a PC,  SpecWare will  ask for  a 

location name. If you are planning to launch loggers with one PC 

and  read  them  with  another,  you  may  wish  to  use  the  default 

name of 

model

-

number

-

serial

-

number 

to make tracking easier.

 

 

Launching Loggers

 

The launch screen is used to configure the logger so it can col-

lect  data.  The  launch  screen  can  be  accessed  by  selecting  the 

Launch  WatchDog  A

-

Series

” 

option  from  the  Logger  menu,  

SpecWare Software 

Содержание WatchDog 3611A

Страница 1: ...A160 Temp RH CO2 Data Logger PRODUCT MANUAL Item 3611A...

Страница 2: ...SpecWare Software 8 Troubleshooting 10 Logger Capacity 15 999 data points 5 333 per sensor CO2 Range 0 to 9999 ppm CO2 Accuracy 50ppm 5 of reading from 0 to 2000 ppm else unspecified Pressure Depende...

Страница 3: ...ger and keep it working accurately for many years Read this manual thoroughly in order to get effective performance from your data logger The A160 logger also has a comprehensive LCD display with cont...

Страница 4: ...meter measures continuously and updates the LCD every second With a significant environmental change the CO2 sensor requires 2 minutes and the RH sensor 10 minutes to respond Note Do not hold the mete...

Страница 5: ...values or ESC to exit without saving Press SET again to enter P1 3 to set the CO2 alarm lower limit exceeding this triggers the alarm Typically the upper level for NORMAL and the lower level for the...

Страница 6: ...software see p 9 What ever value is shown on the LCD will be over ridden when the log ger is launched CO2 Manual Calibration Manual calibration should be done outdoors on a sunny day with fresh air an...

Страница 7: ...river prior to its use The driver is included on the SpecWare Software installation CD for SpecWare 9 Pro or Basic Version 9 01 Build 206 or greater as well as on the SpecWare 9 update page at www spe...

Страница 8: ...is read by SpecWare an initialization screen will open Enter the serial number printed on the bottom of the logger Because you have an A160 the A125 A130 options are ignored Logger Location Names Spe...

Страница 9: ...ce is initiated by selecting the Get Watch Dog A Series data option from the Logger menu clicking the icon on the SpecWare toolbar or from the WatchDog Manager screen When the download is complete the...

Страница 10: ...the AC adapter Shake any water out of the A160 Set the A160 in a ventilated area for at least a day preferably more Do not plug it in until you are confident that any water has evaporated Water damage...

Страница 11: ...appears then con tact your distributor regarding repair E03 Air temperature is above the upper limit Put the meter in regular room temperature for 30 minutes If this still appears then con tact your d...

Страница 12: ...CISPR11 EN 61000 4 2 1995 A1 1998 A2 2001 EN 61000 4 3 2006 This product is warranted to be free from defects in material or work manship for one year from the date of purchase During the warranty pe...