background image

10 

 

 

 

Manufacturer shall not accept any claims when the warranty period expires, if passport for the projector 

is not provided or if Operating Manual is not followed.  

10.

 

TRANSPORTATION AND STORAGE  

Packed IR-projector shall be stored under condition 4 as per GOST 15150.  
For transportation  the  IR-projector shall be packed in  the factory package or suitable box, wrapped in 

air-bubbled film, foam core or other shock absorbent material.  If several items are packed in one box, spacers 
shall be located between them. 

It  is  allowed  to  transport  the  projector  at  any  distance  by  any  transport.  Protection  of  the  transport 

package from precipitation shall be provided for the period of transportation. 

During  loading  and  off-loading  and  during  transportation  the  IR-projector  shall  not  be  exposed  to 

shocks  or  atmospheric  precipitation.  During  transportation  the  box  with  the  IR-projector  shall  be  placed  in 
such a manner that to prevent uncontrolled relocation. 

 

11.

 

ORDERING INFORMATION  

The scope of IR-projector supply includes:  

 

IR-projector ..........................................................................................................  1 pc.;  

 

mounting and positioning device..........................................................................  1 pc.;  

 

fixing clamp for models TKV-300-M-IK and TKV-300-N-IK ...........................  1 pc.; 

 

Silica gel ...............................................................................................................  1 pc.;   

 

label SPEC.732118.019 ET ..................................................................................  1 pc.; 

 

passport SPEC.732118.019 PS .............................................................................  1 pc.;  

 

sun shield (not included in the scope of supply; supplied in separate order)........  1 pc.; 

 

cable gland (not included in the scope of supply; supplied in separate order)…..  2 pcs.   

At the time of order please specify:  

1.

 

Model of IR-projector:

 

 

“TKV-300-N-IK”  -  ex-proof  IR-projector  Relion  (ReliON),  body  material  -  stainless  steel 

12KH18N10T;  

 

“TKV-300-M-IK” - ex-proof IR- projector Relion (ReliON), body material - galvanized low-carbon 

steel St10-20 with powder coating; 

 

“TKV-300-A-IK”  -  ex-proof  IR-projector  Relion  (ReliON),  body  material  -  aluminum  alloy  with 

powder coating.  

2.

 

Radiation angle (illumination range) 

 

Basic configuration: radiation angle 60

0

 at 60m illumination range;  

 

Configuration-to-order: radiation angle 10

0

 at 100m illumination range;   

 

Configuration-to-order: radiation angle 90

0

 at 15m illumination range.  

3.

 

Sun shield - not included in the scope of supply supplied in separate order. 

 
4.

 

Cable glands - 

not included in the scope of supply; supplied in separate order:

 

 

cable glands for “TKV-300-N-IK” are made from 12KH18N10T stainless steel; 

 

cable glands for “TKV-300-M-IK” and “TKV-300-A-IK” are made from St10-20 galvanized steel.  

 

 

 

Содержание Relion-TKV-300-A-IK

Страница 1: ...SPEC 732118 019 RE Agreed FSUE VNIIFTRI OS VSI VNIIFTRI Operating Manual Explosion proof Infrared Projector Relion TKV 300 N IK Relion TKV 300 A IK Relion TKV 300 M IK 2017 ...

Страница 2: ...CTORS AFFECTING VISIBILITY 6 5 ASSEMBLY OF IR PROJECTOR 6 5 1 INSTALLATION OF IR PROJECTOR 6 5 2 PROJECTOR ASSEMBLY PROCEDURE 7 5 3 ELECTRICL INSTALLATION 8 6 TROUBLESHOOTING 9 7 TECHNICAL MAINTENANCE 9 8 REPAIR AND RETURN OF THE DEVICE 9 9 MANUFACTURER S WARRANTY 9 10 TRANSPORTATION AND STORAGE 10 11 ORDERING INFORMATION 10 ...

Страница 3: ... GOST 30852 11 MEK 60079 12 and PUE sec 7 3 The projector body features IP68 class of protection from environmental effect The IR projector is operable within 500 C to 550 C temperature range 8 high power IR emitters with focusing lenses provide back light for distance up to 100m Basic configuration of the projector default option features the following parameters of radiation angle and illuminati...

Страница 4: ...n angle and illumination range are provided optionally by separate order m radiation angle 100 100 radiation angle 900 15 Cover protection class IP 68 Radiating wave length nm 850 Switch on off threshold lx 3 Power voltage V 12 36 DC Consumed current A max 0 5 Power consumption W 6 Weight kg max TKV 300 M IK 4 8 TKV 300 N IK 5 4 TKV 300 A IK 2 7 Temperature range 0 C 50 55 Specified lifetime for t...

Страница 5: ...from galvanized low carbon steel Switching board with terminal boxes used for power cable connection is located on the back cover of the IR projector from the inside Loop power supply for board with IR emitters is connected to the switching board Silica gel is placed into IR projector body for moisture absorption IR projectors Relion TKV 300 M IK and Relion TKV 300 N IK feature the same dimensions...

Страница 6: ... in the present Operating Manual If connection diagrams differ from the recommended connection pattern and are not approved by the manufacturer the warranty period shall be terminated and this may result in IR projector failure Installation and connection of the IR projector shall be performed by authorized personnel only 5 1 INSTALLATION OF IR PROJECTOR IR projector shall be positioned in such ma...

Страница 7: ...Determine operational location and fix the bracket of mounting and positioning device 9 fig 2 and 3 Undo retention screws of the projector back cover 3 Switching board is located on the inside of the back cover fig 5 Carefully take off the cover from the projector body so not to damage power supply loop of the board with IR emitters connected to the switching board Disconnect terminal of the power...

Страница 8: ...l be used Cable cross sections are selected according to the power supply in the line and cable line length All outer mains are connected through inner terminal block which is an integral part of the IR projector For wires with sections from 0 08mm2 to 2 5mm2 pressing camps are used Terminal contacts of the switching board which are located inside terminal block of the IR projector are shown in Fi...

Страница 9: ...tor 7 TECHNICAL MAINTENANCE Inspection window of the IR projector shall be maintained clean for this purpose cleaning shall be performed progressively as dirt accumulation takes place cleaning shall be performed with brush or wet flannel Technical maintenance intervals are determined by technical regulations approved by technical manager of organization 8 REPAIR AND RETURN OF THE DEVICE If any def...

Страница 10: ...positioning device 1 pc fixing clamp for models TKV 300 M IK and TKV 300 N IK 1 pc Silica gel 1 pc label SPEC 732118 019 ET 1 pc passport SPEC 732118 019 PS 1 pc sun shield not included in the scope of supply supplied in separate order 1 pc cable gland not included in the scope of supply supplied in separate order 2 pcs At the time of order please specify 1 Model of IR projector TKV 300 N IK ex pr...

Страница 11: ... 4 thread KV 15 N KV 15 M Cable gland for installation with cable in metal hose with internal diameter D 15mm KV 18 N KV 18 M Cable gland for installation with cable in metal hose with internal diameter D 18mm KV 20 N KV 20 M Cable gland for installation with cable in metal hose with internal diameter D 20mm SHT1 2 KV12 ZG SHT3 4 KV15 Fig 7 Cable gland kit Fig 8 Different input devices 1 body foun...

Страница 12: ...12 MANUFACTURER S ADDRESS 2D Lenin St the Sverdlovsk Oblast 623700 Russia tel 343 379 07 95 info spectron ops ru www spectron ops ru ...