9
When installing
armored
cable assembly operations shall be performed in
the
following sequence:
Remove cable insulation to the length of 140mm.
Remove armor to the length of 100mm.
Remove the inner insulation up to 50mm.
Install the connection cable into the cable gland in compliance with the connection diagram, fig.8
In the case of piping connection, the piping coupling shall be screwed directly on the nozzle with G1/2
or G3/4 thread, fig. 8.
Water resistance
During assembly ensure tightness at installation of cable glands and back cover to prevent the IR-
projector from moisture penetration. Water resistance is an important parameter that ensures stable
performance of the system in the process of operation.
ATTENTION!
Installation company shall be responsible for IR-projector tightness in the process of assembly.
6.
TROUBLESHOOTING
ATTENTION!
The IR-projector does not contain any elements subject to repair by the Customer.
Troubleshooting of the IR-projector shall be performed in the following sequence:
Make sure there is no dirt on the IR-projector glass. Wash the glass with wet flannel in case of dirt.
Check the power supply to the IR-projector.
7.
TECHNICAL MAINTENANCE
Inspection window of the IR-projector shall be maintained clean, for this purpose cleaning shall be
performed progressively as dirt accumulation takes place, cleaning shall be performed with brush or wet
flannel.
Technical maintenance intervals are determined by technical regulations approved by technical
manager of organization.
8.
REPAIR AND RETURN OF THE DEVICE
If any defects or failures occur the Customer solely issues a failure certificate with description of the
defect. The IR-projector with passport and failure certificate shall be returned to the manufacturer.
The IR-projector shall be properly packed for transportation. Package information is specified in
section 10 of “Transportation and storage”. In case of return please dispatch the product to the address: 2D
Lenin Str., Beryozovsky, the Sverdlovsk Oblast, 623700, Russia, tel.: (343)379-07-95.
9.
MANUFACTURER’S WARRANTY
Specified lifetime for the IR-projector is 10 years minimum.
Warranty period - 12 months from the date of commissioning.
After 24 months of service supplementary warranty period shall be issued via service WARRANTY
EXTENSION at http://spectron-ops.ru/.
Warranty repairs in compliance with GOST R 52350.19 or IR-projector replacement shall be performed
by the manufacturer only if the Customer follows all transportation, storage and operation requirements.