![Spectron BE56-2U Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/spectron/be56-2u/be56-2u_user-manual_1344153016.webp)
5 | Installation
Spectron Gas Control Systems GmbH
16
GES_BE56-2U_0720
5 Installation
5.1 General information
CAUTION
Injury or damage in the event of incorrect assembly or disassembly
Special steps are required for assembly and disassembly work on the product. Personal injuries
and damage to the product are possible.
a) Assembly and disassembly work may only be carried out by the installation engineer or ap-
propriately skilled specialist companies and persons.
b) The product is not permitted to be re-used following disassembly. All components must be
disposed correctly.
Depending on the type of gas, different requirements apply to the installation space of gas sup-
ply systems. It is essential to observe the legal regulations and trade association regulations,
and the information in the safety data sheets.
Familiarise yourself with the necessary work steps (see "
the necessary tools.
See also
2
5.2 Installation work
5.2.1 Installation
The Pressure control panel can be mounted into a gas cylinder cabinet or on the room wall us-
ing C-mounting rails.
Step 1.
Attach the basic profile to the wall using suitable
screws and dowels. The vertical distance between the
centre of the basic profile and the central axis of the
cylinder valve connection thread is approx. 220 mm.
Note the sticker "Top – Oben", which is attached to
the inside of the basic profile and shows the correct
mounting direction for the plate.
Step 2.
Now slide the plate with the attached fittings into the
upper
groove from below