3
Note:
For assistance of any kind, contact the Customer Service Department at Spectronics. In the United States and Canada, call
toll-free by dialing
. Give the model and serial numbers of the unit and the date of purchase. To read the serial number,
open the tailcap of the lamp and remove the battery stick. The serial number label is inside the barrel of the lamp.
Note:
For assistance of any kind, contact the Customer Service Department at Spectronics. Give the model and serial numbers of
the unit and the date of purchase. To read the serial number, open the tail cap of the lamp and remove the battery stick. The serial
number label is inside the barrel of the lamp.
en
Warranty/Registration
To review the warranty policy:
To register the product online:
spectroline.com/warranty-registration
Technical Specifications
Light Source
UV LED (365 nm)
Power Source
(1) proprietary LI-ION battery
Run Time
9 hours (continuous)
Lamp Head Diameter
1.62 in (4.11 cm)
Lamp Length
6.56 in (16.7 cm)
Weight
0.50 lbs. (0.23 kg) (without
batteries); 0.70 lbs. (0.32 kg)
(with battery)
Replacement Parts And Accessories
Description
Part No
.
RP-CAS-01
Charging adapter set, Type A
Plug (USA)
RP-CAS-01-F
Charging adapter set, Type C
Plug (EU)
RP-LIB-03
Lithium-ion battery
RP-UVS-30
Spectacles, UV-absorbing
LASER POINTER:
The LeakTracker™ Plus Rechargeable features an integrated laser pointer. This feature is
designed to aid in pinpointing leak sites. Press and hold the button labeled “laser” to turn the laser pointer ON. To turn
the laser pointer OFF, remove your finger from the button.
It is important to adhere to the following warnings and safety instructions to prevent injury:
1. Never shine a laser pointer into a person’s eyes or stare into the laser beam.
This can cause instant temporary
vision dysfunction such as flash-blindness, disorientation, or glare. This can be particularly dangerous if the exposed
person is engaged in a vision-critical activity such as driving. In addition, prolonged and/ or repeated exposure to the
laser beam can be hazardous and damaging to the eyes.
2. Never aim a laser pointer anywhere at or near any person or animal.
Laser pointers are designed to point at
inanimate objects only. In some states and provinces, it is illegal to aim a laser pointer at a law enforcement officer or
any other person. The purchaser/ user is responsible for ensuring that his or her use of the laser pointer conforms to
any local laws.
3. Do not point a laser at mirror-like surfaces
. A reflected beam can act like a direct beam to the eye.
4. Laser pointers are not toys.
Do not allow a minor to use a laser pointer unsupervised. In some states and
provinces, it is illegal for a minor to purchase and/or use a laser pointer. The purchaser/user is responsible for
ensuring that his or her purchase or use of the laser pointer conforms to any local laws or jurisdictions.
ADJUSTABLE FOCUS LENS:
Turn the lamp head counterclockwise to expand the beam profile. Use the wide beam
setting to scan a large area for leaks. Turn the lamp head clockwise to narrow the beam profile. Use the narrow beam
setting to increase the light intensity. The narrow beam setting helps to fluoresce the smallest leaks.
CLEANUP/REINSPECTION:
After the leaks are repaired, clean the remaining dye from the leak sites with Spectroline
®
GLO-AWAY™ PLUS dye cleaner or a shop solvent. Remaining dye could be mistaken for a leak. Check all areas
again with the lamp to make sure no dye remains. Run the system for another 5 to 10 minutes and reinspect with the
LeakTracker™ Plus Rechargeable. No glow means that all leaks have been properly repaired.
LASER RADIATION
Complies with 21 CFR 1040.10 and 1040.11 except for
conformance with IEC 60825-1 Ed. 3., as described in Laser
Notice No. 56, dated May 8, 2019.
MAXIMUM OUTPUT:
<1 mW |
EMITTED WAVELENGTHS:
650 nm
IEC 60825-1:
2014-05
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
ENVIRONMENTAL SPECIFICATIONS:
The LeakTracker™ Plus lamp is designed to be safe under the following conditions:
z
For Indoor/Outdoor Use (dustproof and protected against water pressure)
z
Temperature 41°F to 122°F (5°C to 50°C)