15
S2/S9
The sensitivity of the transducer changes when operating in four-wire
connection. The change in the thermal coefficient of sensitivity (TK
C
) is
negligibly small. Changing the cable length changes the sensitivity.
There is no correction for the effects of temperature on the cable.
wh (white)
bk (black)
rd (red)
bu (blue)
gn (green)
gy (grey) / or (orange)
1)
Shielding
2)
Measurement signal (+) U
A
Excitation voltage (+) U
B
Sensor circuit (–)
Sensor circuit (+)
Excitation voltage (–) U
B
Measurement signal (–) U
A
Cable shielding, connected to
housing
Six-wire connection
Four-wire connection
1)
for transducer S2
If you connect the transducer to an amplifier using four-wire connection, you must
connect the sensor circuit to the appropriate bridge excitation circuit:
Connect sensor circuit (–) (grey / orange
1)
) to excitation voltage (–) (black)
and
sensor circuit (+) (green) to excitation voltage (+) (blue)
Shielding
3)
2)
for S2: shielding only (without soldered yellow stranded wire)
3)
for S9: yellow stranded wire soldered to shielding
Fig. 6.1:
S2/S9 pin assignment