51
FR
RS-485 Command set
Command
Command
Remark
Ex
ample
av
ailable in
ON/OFF mode
av
ailable in
PL
C mode
Lamp
s OFF
PL0
All lamp
s OFF
X
X
Lamp
s ON
PL1
All lamp
s ON
X
X
Pr
ogr
am UP
Ps
U
Jump t
o ne
xt pr
ogr
am
X
X
Pr
ogr
am Do
wn
Ps
D
Re
turn t
o pr
evious pr
ogr
am
X
Se
t Pr
ogr
am
PSxx
xx is the decimal r
epr
esen
ta
tion
of the pr
ogr
am number (01 - 14)
PS06 = jump t
o pr
ogr
am 6
X
Aut
o s
ync pr
ocedur
e
Ps
S
ex
ecut
es the aut
o s
ync pr
ocedur
e (see pag
e 10)
X
X
Whit
e 1
PW1
Jump t
o Whit
e 1 (pr
ogr
am 12)
X
Whit
e 2
PW2
Jump t
o Whit
e 2 (pr
ogr
am 13)
X
Whit
e 3
PW3
Jump t
o Whit
e 3 (pr
ogr
am 14)
X
Se
t R
GB
PCrrr
gg
gbbb
rrr
, g
gg and bbb ar
e the decimal r
epr
esen
ta
tion
of the R
GB v
alue (with leading z
er
o’
s)
1) PC255128064 = Full output le
vel on R
ed c
olor
, half out
-
put le
vel on Gr
een c
olor
, 1/4 output le
vel on Blue c
olor
2) PC255255255 = All c
olor
s a
t full output le
vel
3) PC000000000 = All c
olor
s OFF
X
Se
t Dim v
alue
PDxxx
se
t the OUTPUT v
alue of the lamp in % (000 -
100)
PD075 = 75% output le
vel (on all LED
’s)
X
se
t DMX s
tartAdr
ess
PAxxxy
z
y = ‘
e’ or ‘E’
PA035E = se
t DMX s
tart addr
ess t
o 35 [35(R), 36(G),
37(B)]
X
Se
t c
olor in per
cen
tag
e
Ppr
gbe
variable
siz
e,
rgb = ASCII 0-255,
e = end
char
act
er
Pp25050100e = R
ed 25%, Gr
een 50%, Blue 100%
X
Se
t c
olor in he
x
Pcr
gbe
variable
siz
e,
rgb = ASCII 0-255,
e = end
char
act
er
Pc64128255e = R
ed 25%, Gr
een 50%, Blue 100%
X
Rela
y A c
on
tr
ol
PRAx
x = 1 (ON), 0 (OFF), P (Pulse) !this o
verrules
dip
swit
ch
PRA1 = R
ela
y A ON PRA0 = R
ela
y A OFF
X
X
Rela
y B c
on
tr
ol
PRB
x
x = 1 (ON), 0 (OFF), P (Pulse) !this o
verrules
dip
swit
ch
PRB1 = R
ela
y B ON PRB0 = R
ela
y B OFF
X
X
ON/OFF r
ela
y c
on
tr
ol
PRMx
x = 1 (ON), 0 (OFF)
PRM1 = R
ela
y ON/OFF c
on
tr
ol ON
X
X
Color t
emper
atur
e
PTx
yz
x = t
en thousand ; y = thousand ; z = hundr
ed
PT035 = Se
t whit
e c
olor t
emper
atur
e t
o 3500K (in s
tep
s
of 500K)
X