6
Installation Instructions
Single PLP-REM unit
.
Connect a 12VAC magnetic transformer to the “12VAC FROM TRANSFORMER”
terminal of the PLP-REM.
Connect the pool lights to the “12VAC TO LAMPS” terminal in the PLP-REM.
.
Install the filter (included in box) to the primary circuit (230VAC side)
of the transformer
.
The “12VAC TO LAMPS” relay contact has a max rating of 60A. Make sure the
total power load does not exceed this (60A x 12VAC = 720VA)
12VAC
230VAC
C
C