SpectraPure
®
NOTE: It is recommended that at least 2 gallons (7.57 liters) of purified water
be discarded now before collecting purified water for use. If the unit
is not used for several days, run the system for at least 10 minutes
before collecting any water. This will flush out any stale water in the
system.
13. Finish the installation by directing the yellow line to a drain.
14. Install the included Float Valve onto a collection reservoir.
15. Attach the blue line to the Float Valve.
NOTE: It may take several days of normal operation for the membrane to
reach its full production rate.
INSTALL THE FLOAT VALVE:
1. Drill a 1/2" hole near the top of your reservoir:
NOTE: If you are installing the Float Valve onto an acrylic tank we recommend
using a new Fostner Bit to reduce the chance of cracking the acrylic.
2. (Refer to Diagram on next page) Remove the Compression Nut from
the float body.
3. Insert the 1/4" Blue Tubing into the 1/2" Compression Nut with the
threads towards the end of the tube.
4. Unscrew and remove the remaining nut from the float body.
5. Insert the float body and washer into the 1/2" hole and tighten the
nut, which securely tightens the float to the tank wall.
6. Push the Compression Nut towards the end of the tubing and screw
the Compression Nut back onto the float body.
7. To tighten, use one 1/2" wrench on the flats of the plastic threads and
another 1/2" wrench on the Compression Nut.