background image

SpectraPure

®

Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

19

SpectraPure

®

THREE YEAR LIMITED WARRANTY:                                          

All standard water purification products manufactured by SpectraPure have a 3 year limited 

warranty, except the Eliminator™ MarinePro™, Industrial, Laboratory, Custom Systems, Commercial 

and electrical products which have a 1 year limited warranty. LiterMeters™ & UPLC™ have a 5 year 

limited warranty. OEM equipment resold by SpectraPure (pumps and monitors) carry the original 

manufacturer’s warranty. 

SpectraPure, Inc.

®

 warrants the product to the original owner only to be free of defects in material 

and workmanship for a period of three years from the date of receipt. SpectraPure’s liability under 

this warranty shall be limited to repairing or replacing at SpectraPure’s option, without charge, 

F.O.B. SpectraPure’s factory, any product of SpectraPure’s manufacture. SpectraPure will not be 

liable for any cost of removal, installation, transportation or any other charges which may arise in 

connection with a warranty claim. Products which are sold but not manufactured by SpectraPure 

are subject to the warranty provided by the manufacturer of said products and not by SpectraPure’s 

warranty. SpectraPure will not be liable for damage or wear to products caused by abnormal 

operating conditions, accident, abuse, misuse, unauthorized alteration or repair or, if the product 

was not installed in accordance with SpectraPure’s or other manufacture’s printed installation and 

operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God. 

SpectraPure will not be responsible for any consequential damages arising from installation or use 

of the product, including any water or mold damage due to flooding which may occur due to 

malfunction or faulty installation, including, but not limited to failure by installer to over- or under-

tighten fittings, housings, and/or push-style fittings, or improper installation of push-style fittings. 

Consumable items such as prefilters and membranes are not covered under the 3 year warranty.

SpectraPure warrants (prorated) the performance of tested SpectraSelectPlus™ RO membrane 

elements only, for one year from date of receipt by the buyer, providing that the loss of performance 

was not caused by fouling, neglect or water conditions exceeding the feed water parameters listed 

in the applicable product manual (refer to detailed membrane warranty information). SpectraPure 

will, on confirmation of loss of performance during the warranty period, credit the prorated amount 

of the current catalog price of the element. The disposable filters and  cartridges are not covered 

under the warranty.

To obtain service under this warranty, the defective system or components must be returned to 

SpectraPure with proof of purchase, installation date, failure date and supporting installation data. Any 

defective product to be returned to the factory must be sent freight prepaid; documentation supporting 

the warranty claim and a Return Merchandise Authorization (RMA) number must be included. 

SpectraPure will not be liable for shipping damages due to the improper packaging of the returned 

equipment and all returned goods must also have adequate insurance coverage and a tracking number. 

SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, 

proliferation, spread or any activity of “fungus”, wet or dry rot or bacteria. Such loss or damage is 

excluded regardless of any other cause or event that contributes concurrently or in any sequence 

to the loss. We will not pay for loss or damage caused by or resulting from continuous or repeated 

seepage or leakage of water, or the presence or condensation of humidity, moisture or vapor, that 

occurs over a period of 14 days or more. “Fungus” and “fungi” mean any type or form of fungus or 

Mycota or any byproduct or type of infestation produced by such fungus or Mycota, including but 

not limited to, mold, mildew, mycotoxins, spores, scents or any biogenic aerosols. 

SpectraPure will not be liable for any incidental or consequential damages, losses or expenses 

arising from installation, use, or any other causes. There are no expressed or implied warranties, 

including merchantability or fitness for a particular purpose, which extend beyond those warranties 

described or referred to above.

* The three year limited warranty does not apply to consumable items, including but 

not  limited to, filters and cartridges unless specifically stated above.

Содержание CSP Series

Страница 1: ... System Single and Dual Membrane Models INSTALLATION AND OPERATING MANUAL WARNING Please read carefully before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property ...

Страница 2: ...tem Specifications 4 System Description 5 6 What Is Reverse Osmosis 7 Installation System Initialization 8 Working With Push Fittings 9 Maintenance Sediment Prefilter Replacement 10 Carbon Block Filter Replacement 11 Metering and Diagnostics 12 RO Membrane Replacement 13 14 Membrane Output Calculation 15 16 Troubleshooting Guide 17 Troubleshooting Guide 17 Tips and Storage Choosing a Mounting Loca...

Страница 3: ...thout notice when necessary All prices in the catalog are quoted in US dollars 7 Claims for error in quantity or condition must be made within 10 days of receipt of material SpectraPure Inc Will not be responsible for any claimed shortages not reported within 10 days Returns other than warranty claims may be subject to 20 restocking fee 8 SpectraPure Inc cannot be held liable for damage or loss to...

Страница 4: ...08 ml min 180 680 473 ml min 1419 ml min Reverse Osmosis Feed Water Requirements For the 1 year TFC membrane prorated warranty to be honored the following conditions must be met Operating Pressure 40 80 psi 2 75 5 5 bar pH Range 3 11 Maximum Temperature 113 F 45 C Maximum Turbidity 1 0 NTU Maximum Silt Density Index 5 0 based on 15 min test time Maximum Chlorine less than 0 1 ppm Maximum TDS 2000 ...

Страница 5: ...anics and chlorine from the feed water that can damage the membrane 3 The third filtration stage of the system is a high rejection thin film composite TFC reverse osmosis membrane It removes over 96 of most inorganic salts all microorganisms and almost all high molecular weight organics in the water Fig A System Diagram TFC RO Membrane inside housing 0 5 micron MicroTec Sediment Prefilter SF MT 0 ...

Страница 6: ...SpectraPure SpectraPure Inc 480 894 5437 Call us toll free 1 800 685 2783 2167 East Fifth St Tempe Arizona 85281 6 SINGLE MEMBRANE SYSTEM FIGURE B DUAL MEMBRANE SYSTEM FIGURE C ...

Страница 7: ...le over 98 of most salts and other impurities are rejected and automatically rinsed from the membrane down the drain Figure 1 Figure 3 Figure 2 WHAT DOES THE SYSTEM DO SpectraPure s CSP RO System uses household water pressure to reverse a natural physical process called osmosis Water under pressure is forced through a semipermeable membrane where minerals and impurities are screened out and sent d...

Страница 8: ...pen the cold water supply valve You may use pressure up to 80 psi 5 5 bar CAUTION Check the system to ensure that all fittings are tight and leak free before leaving the system unattended If anything is leaking contact SpectraPure for assistance NOTE It is recommended that at least 2 gallons 7 57 liters of purified water be discarded now before collecting purified water for use If the unit is not ...

Страница 9: ...eal inside the push fitting by dripping a few drops of clean water into the fitting 2 Grasp the tubing near the end and insert the tubing into the push fitting 3 Push the tubing into the fitting until resistance is felt approximately 1 2 inch 12 7 mm The tubing is now resting on the O ring seal inside the fitting 4 Firmly push the tubing approximately an additional 1 4 inch 6 35 mm further into th...

Страница 10: ...ove the sediment and the pressure does not return to normal the carbon filter may be plugged If your water contains a great deal of sediment or chlorine the prefilters may require more frequent changes to maintain adequate production rate and extended membrane life Sediment Prefilter Replacement Materials Required 0 5 micron MicroTec Sediment Filter SF MT 0 5 10 Filter Wrench Procedure 1 Turn off ...

Страница 11: ... become saturated with contaminants but a carbon filter can also decrease production if it s covered with extremely fine sediment If the carbon becomes plugged with sediment it will no longer be able to remove chlorine Carbon Block Filter Replacement Materials Required 0 5 micron Carbon Block Filter CF 0 5 10 Filter Wrench Chlorine Test Kit TK CL 10 KIT Procedure 1 Turn off water supply to the sys...

Страница 12: ...ssure would indicate that the prefilters are in need of replacement USING THE DUAL PROBE TDS METER DM1 METER The digital TDS meter dual probe will provide a reliable means of evaluating the performance of the RO membrane The numbers from the two probe readings can be used to calculate the percentage of rejection of the TFC RO membrane The IN position of the switch relates to the IN probe installed...

Страница 13: ...g lid This may require two people 5 Use a pair of pliers to grasp the membrane stem and pull the membrane from the housing Fig D Fig D Removing the Membrane Element black membrane brine seal black membrane housing O ring membrane product water tube 6 Remove the black housing O ring Fig D Wash the empty housing with soapy water Rinse thoroughly with hot clean water 7 Insert new membrane into the ho...

Страница 14: ...t Tempe Arizona 85281 14 8 Place the black housing O ring on the housing rim and carefully screw the lid back on to the base 9 Housing O Ring Reconnect the black tubing to the membrane feed push fitting NOTE If you have a dual membrane system perform steps 2 thru 9 on the second membrane now ...

Страница 15: ...ional to the applied pressure NOTE The membrane is rated to produce the rated GPD at 60 psi For any pressure other than 60 psi the output GPD is multipled by the PCF PCF Line Pressure in psi 60 Calculation of Temperature Correction Factor TCF The output GPD also decreases with decrease in temperature This is because water viscosity increases with decrease in water temperature Temperature Correctio...

Страница 16: ... the quality of the membrane once every 6 months Note This procedure will require the use of the DM 1 TDS Meter Procedure 1 Measure tap water TDS This is the IN setting on the meter Call it X 2 Run the system for 10 15 minutes 3 Measure RO water TDS directly on the OUT setting on the meter Call it Y 4 Subtract RO water TDS from tap water TDS X Y 5 Divide this quantity by tap water TDS X Y X 6 Reje...

Страница 17: ...lusion TDS Conductivity Tester Measure feed water X RO product water Y for TDS Conductivity Is Rejection greater than 95 No Replace Membrane Yes Membrane OK Alkalinity Test Kit Measure feed water X RO product water Y for Alkalinity Is Rejection greater than 90 No Replace Membrane Yes Membrane OK Hardness Test Kit Measure feed water X RO product water Y for Hardness Is Rejection greater than 90 No ...

Страница 18: ...nit is used outside avoid putting the system in direct sunlight or connecting it to a garden hose that may be exposed to sunlight TIPS FOR LONG MEMBRANE LIFE 1 Replacement of 0 5 micron sediment filter once every 6 months This will prevent membrane fouling due to silt or sediment depositing on the membrane 2 Replacement of 0 5 micron carbon block filter at least once every 6 months or when chlorin...

Страница 19: ...mance of tested SpectraSelectPlus RO membrane elements only for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty ...

Страница 20: ...ctors have a 3 1 waste ratio recommended for water 180 ppm ACCESSORIES Part Number Description MTR TDS EZ Hand held TDS Meter COM 100 Hand held Conductivity Meter MTR PH80 Hand held pH Meter FAU SNP Quick Connect Faucet Adapter TK CL 10 KIT Total Chlorine Test Kit TK CL 10TABS 10 Replacement Tabs for Chlorine Test Kit GHA 4 1 4 Garden Hose Adapter WR UNIV Filter Wrench VA FVK 4 Flush Valve Kit BPL...

Отзывы: